{"product_id":"allen-bradley-842hr-sjdz115fwy2","title":"Allen-Bradley 842HR Sin\/Cos Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for 842HR installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Allen-Bradley 842HR Sin\/Cos Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA qualified technician can compare the RS-485 position\/status and each analog channel using a compatible receiver or instrument. Confirm any Mitchell configuration for the exact part and loom. A bench encoder test and a complete motor run require separate setups.\u003c\/p\u003e\n\u003ch2\u003eAllen-Bradley 842HR Sin\/Cos Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003e842HR-SJDZ115FWY2\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e842HR-SJDZ115FWY2\u003c\/th\u003e\n\u003ctd\u003eSquare flange, 3\/8 in solid shaft, MS 10-pin.\u003c\/td\u003e\n\u003ctd\u003eSingleturn, 5–12 V supply code 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e842HR-MJDZ115FWY2\u003c\/th\u003e\n\u003ctd\u003eSame listed square-flange shaft and MS 10-pin connection.\u003c\/td\u003e\n\u003ctd\u003eMultiturn, 4,096 turns.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e842HR-SJDZ115FWYD\u003c\/th\u003e\n\u003ctd\u003eSquare-flange 842HR-S with M23 17-pin connector.\u003c\/td\u003e\n\u003ctd\u003eSingleturn. Use the separate M23 pin map and drive cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eRockwell's exact 842HR-SJDZ115FWY2 product record listed lifecycle Active when reviewed. Confirm regional orderability separately. \u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.842HR-SJDZ115FWY2.html\"\u003eRockwell exact product record\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for 842HR-SJDZ115FWY2\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for 842HR-SJDZ115FWY2\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback\u003c\/th\u003e\n\u003ctd\u003e32,768 absolute steps per turn for 842HR-S, plus 1,024 sin\/cos periods per turn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e5–12 V DC for code 1. 180 mA maximum no-load current in the 5–12 V family column. Allow for the documented inrush.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical\u003c\/th\u003e\n\u003ctd\u003e3\/8 in solid shaft with square flange. Operating speed up to 6,000 rpm per 842HR-IN001.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e−20 to +85 °C. IP66 when the matching connector is inserted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eMS 10-pin for termination code 2. D denotes the distinct M23 17-pin version.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/842hr-in001_-en-p.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the square-flange, solid-shaft drawing on page 2. Mount the housing on the bracket and couple the 3\/8 in shaft to the driven shaft with the correct two bore sizes. Check concentricity, shaft insertion, end load and coupling slip. Rockwell lists 845-FC flexible couplings, including 845-FC-B-B for 3\/8 in at both ends. Use that coupling's assembly instructions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive reads absolute position and parameters on bidirectional RS-485, then uses differential sin\/cos for high-resolution motion feedback. Rockwell documents HIPERFACE compatibility. A stable serial position and faulty analog motion feedback can produce different alarms. Check each analog signal against its own reference.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the MS 10-pin row of 842HR-IN001, page 2. Read contact letters on the connector and use its keyed view. The M23 version has different contacts.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"MS 10-pin 842HR code 2\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMS 10-pin 842HR code 2\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRockwell cable color\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA\u003c\/th\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eB\u003c\/th\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eC\u003c\/th\u003e\n\u003ctd\u003eREF SIN\u003c\/td\u003e\n\u003ctd\u003eBrown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eD\u003c\/th\u003e\n\u003ctd\u003eREF COS\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE\u003c\/th\u003e\n\u003ctd\u003eData +\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eF\u003c\/th\u003e\n\u003ctd\u003eData −\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eG\u003c\/th\u003e\n\u003ctd\u003eSIN\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eH\u003c\/th\u003e\n\u003ctd\u003eCOS\u003c\/td\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eI\u003c\/th\u003e\n\u003ctd\u003eUnused\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJ\u003c\/th\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe 842HR-CA-2-yy family uses an MS 10-pin encoder plug and flying leads. Rockwell lists -01, -03, -05 and -10 among the length options. Use the controller's cable and shielding rules. A 2090-XXNFMF-Sxx lead is documented for the different M23 variant.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial position absent\u003c\/th\u003e\n\u003ctd\u003eCheck the correct single supply, return, and Data pair at both ends using the approved test method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial good, speed signal unstable\u003c\/th\u003e\n\u003ctd\u003eCheck SIN\/REF SIN and COS\/REF COS, coupling fit and cable integrity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition shifts under load\u003c\/th\u003e\n\u003ctd\u003eInspect bracket and coupling retention while isolated. Verify the reference and drive configuration after repair.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eRockwell positions 842HR for auxiliary servo feedback. Kinetix documentation lists specific 842HR connector variants. Match the exact receiver and harness. The Kinetix 6000 example names the M23 suffix D, so confirm the MS version's drive-side wiring separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet the mounting and coupling alignment first. Determine whether the encoder is auxiliary axis feedback or part of a motor commutation scheme. For the latter, use the exact motor procedure and valid original offset data. Confirm direction and axis reference in the drive's approved commissioning mode.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/842hr-in001_-en-p.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.842HR-SJDZ115FWY2.html\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/2094-um001_-en-p.pdf\"\u003eKinetix 6000 user manual\u003c\/a\u003e. Check the named M23 encoder variants and drive configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.842HR-MJDZ115FWY2.html\"\u003eMultiturn relative\u003c\/a\u003e. The exact MS 10-pin multiturn model.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118408695973,"sku":"TCG56","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Allen-Bradley842HRSinCosEncoder.jpg?v=1794142817","url":"https:\/\/www.sparefaber.com\/ar\/products\/allen-bradley-842hr-sjdz115fwy2","provider":"SpareFaber","version":"1.0","type":"link"}