{"product_id":"ams-as5311-atst-magnetic-linear-encoder-ic","title":"ams OSRAM AS5311 AS5311-ATST Magnetic Linear Encoder IC | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE diagnosis and bench evaluation for equipment using the AS5311 magnetic position IC. We help separate sensor, magnetic strip and host board faults and scope repair from the board revision.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"ams OSRAM AS5311 AS5311-ATST Magnetic Linear Encoder IC technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSensor and magnetic strip diagnosis, Board-level evaluation. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA board fixture can check power, magnet diagnostics, A\/B\/index, synchronous serial or PWM as used by the host. Use the approved fixture and ESD controls. A general motor encoder tester does not identify a board pinout.\u003c\/p\u003e\n\u003ch2\u003eams OSRAM AS5311 AS5311-ATST Magnetic Linear Encoder IC technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eAS5311-ATST\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cp\u003eManufacturer device order code\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAS5311-ATST\u003c\/th\u003e\n\u003ctd\u003e20-pin TSSOP encoder IC. Confirm board footprint and magnet layout.\u003c\/td\u003e\n\u003ctd\u003eIncremental A\/B\/index, SSI-style serial and PWM functions documented for the IC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAS5311-ATSU\u003c\/th\u003e\n\u003ctd\u003eOrder variant listed in the same sheet. Confirm packaging and component revision.\u003c\/td\u003e\n\u003ctd\u003eUse the exact bill of materials and order guide before changing the board.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for AS5311-ATST\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for AS5311-ATST\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensing\u003c\/th\u003e\n\u003ctd\u003eHall-based position sensing with a multipole magnetic strip or ring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition within a pole pair\u003c\/th\u003e\n\u003ctd\u003e12-bit position over the specified 2 mm pole pair. Multi-pole travel needs the host’s tracking and reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput groups\u003c\/th\u003e\n\u003ctd\u003eA\/B\/index, serial clock and data, PWM and magnet range diagnostics.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoard and supply\u003c\/th\u003e\n\u003ctd\u003e20-pin TSSOP. Follow the exact 3 V or 5 V configuration and logic-level guidance in the data sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical interface\u003c\/th\u003e\n\u003ctd\u003eMagnetic strip or ring is external. Use the manufacturer geometry and field requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/datasheet.datasheetarchive.com\/originals\/distributors\/DKDS-7\/120483.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the board drawing and datasheet magnet orientation. Check package placement, strip pitch, relative motion and the sensor-to-magnet spacing. Magnet strength and alignment affect signal quality even when the host supply is correct.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eIncremental outputs track relative movement. The synchronous serial and PWM position information represents position within a magnetic pole pair. The host needs the correct reference or counting method to distinguish repeated periods along a long strip.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eIC package pin numbers below come from the AS5311 data sheet. Use the PCB’s view and host schematic before probing.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Verified contact map\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eVerified contact map\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact or group\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4 \/ 5 \/ 7\u003c\/th\u003e\n\u003ctd\u003eIncremental A \/ B \/ index.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e12 \/ 13 \/ 14\u003c\/th\u003e\n\u003ctd\u003eSerial DO \/ CLK \/ active-low CSn. Follow the datasheet’s mode and timing requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2 \/ 3 \/ 15\u003c\/th\u003e\n\u003ctd\u003eMagINCn \/ MagDECn \/ PWM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8 \/ 18 \/ 19\u003c\/th\u003e\n\u003ctd\u003eVSS \/ VDD3V3 \/ VDD5V. Use the published supply circuit for the selected mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOther pins\u003c\/th\u003e\n\u003ctd\u003eCheck the datasheet for NC and Prog handling. Keep unconnected pins as specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThis is an IC with no standalone motor cable. Identify board nets and the host connector from the system schematic. If the host harness is part of the symptom, verify its exact end-to-end path separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003eUse ESD controls and de-energize the board before inspecting or changing connections. Follow the PCB schematic and use its documented test points.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback only works at some points of travel\u003c\/th\u003e\n\u003ctd\u003eInspect strip condition, alignment and spacing. Compare the magnet diagnostics with the mechanical position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeating absolute position every pole pair\u003c\/th\u003e\n\u003ctd\u003eCheck whether the host expects within-period data or full travel. Verify the reference and incremental accumulation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo incremental transitions with valid serial response\u003c\/th\u003e\n\u003ctd\u003eCheck the mode-select state and board receiver. Verify A\/B with the published circuit and logic levels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can use the approved host-board test setup to verify the configured supply, logic signals and magnet response. Isolate the board before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse in embedded linear or off-axis position systems designed for the AS5311. Record the PCB revision, magnetic strip or ring and host firmware. The exact implementation determines test access.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eEstablish the sensor-to-magnet geometry and host reference using the machine or board instructions. Confirm the reported position throughout travel after any board or strip replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/datasheet.datasheetarchive.com\/originals\/distributors\/DKDS-7\/120483.pdf\"\u003eMain technical PDF\u003c\/a\u003e. ams manufacturer data sheet, public mirror. Use pin table, supply configuration and magnet mounting sections.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.infineon.com\/part\/AS5311\"\u003eManufacturer reference\u003c\/a\u003e. Current AS5311 product documentation is hosted by Infineon. The referenced legacy data sheet identifies the ams ordering code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51126572089509,"sku":"TCG163","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/ams-as5311-atst-magnetic-linear-encoder-ic-service-guide.jpg?v=1794221603","url":"https:\/\/www.sparefaber.com\/ar\/products\/ams-as5311-atst-magnetic-linear-encoder-ic","provider":"SpareFaber","version":"1.0","type":"link"}