{"product_id":"asm-posiwire-ws12-3000-mssi-draw-wire-sensor","title":"ASM POSIWIRE WS12 WS12-3000-50-MSSI-L10-M4-M12A8 SSI Draw-Wire Position Sensor | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for ASM WS12 draw-wire installation and fault diagnosis. We help separate travel and cable problems from SSI receiver and wiring faults.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"ASM POSIWIRE WS12 WS12-3000-50-MSSI-L10-M4-M12A8 SSI Draw-Wire Position Sensor technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eDraw-wire diagnosis, Installation, Travel verification. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA fixture can compare position against known travel and evaluate SSI response with the specified receiver. Inspect cable travel and return independently. Exact Mitchell fixture support remains open.\u003c\/p\u003e\n\u003ch2\u003eASM POSIWIRE WS12 WS12-3000-50-MSSI-L10-M4-M12A8 SSI Draw-Wire Position Sensor technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eWS12-3000-50-MSSI-L10-M4-M12A8\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cp\u003eASM documents this as a standard ordering example. Match the complete fitted nameplate and drawing before using its specifications.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWS12-3000-50-MSSI-L10-M4-M12A8\u003c\/th\u003e\n\u003ctd\u003e3,000 mm draw-wire range, M4 cable fixing and 8-pin M12 electrical connection.\u003c\/td\u003e\n\u003ctd\u003e50 µm resolution, MSSI output, L10 linearity option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWS12 with another output suffix\u003c\/th\u003e\n\u003ctd\u003eThe cable stroke and attachment may differ.\u003c\/td\u003e\n\u003ctd\u003eMatch SSI versus analogue, incremental or fieldbus variant from the actual code.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for WS12-3000-50-MSSI-L10-M4-M12A8\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for WS12-3000-50-MSSI-L10-M4-M12A8\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring range\u003c\/th\u003e\n\u003ctd\u003e3,000 mm in the ordering example.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution and linearity\u003c\/th\u003e\n\u003ctd\u003e50 µm resolution. L10 denotes ±0.10% of full scale in the ASM order key.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical attachment\u003c\/th\u003e\n\u003ctd\u003eM4 draw-wire fixing. Check the intended travel path, retraction limits and housing drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical connection\u003c\/th\u003e\n\u003ctd\u003eM12A8, 8-pin M12 for this ordering example.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eMSSI synchronous serial output. Match data length, encoding and receiver settings from the MSSI section.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.asm-sensor.com\/files\/asmTheme\/pdf\/asm_posiwire_ws12_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eAlign the cable outlet with the full travel and use the specified attachment. Avoid side pull, abrasion and overtravel. Route the moving cable so it cannot catch on a guard, sheave or cable chain.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe draw-wire mechanism converts travel into rotation inside the housing. A magnetic absolute encoder reports position via synchronous serial clock and data. A mechanically stuck or slipping cable can return a stable digital value that disagrees with actual travel.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the MSSI connection table for the actual M12A8 configuration, paying attention to the mating-connector view. Verify supply\/return, differential clock and data pairs, and shield. Use the table for the exact output because other WS12 variants share the housing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe draw wire is the measuring element. The separate M12 cordset carries SSI and supply. Match ASM’s M12A8 accessory and the receiving hardware before ordering an extension.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003eSecure the moving load and keep clear of the spring-loaded draw wire. Do not release an extended cable or dismantle the spring housing as part of a basic check.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValue stops changing partway through travel\u003c\/th\u003e\n\u003ctd\u003eCheck the physical attachment and line of pull, then compare actual displacement with the readout.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire retracts poorly or visibly frays\u003c\/th\u003e\n\u003ctd\u003eSecure the load and isolate the assembly. Inspect the route and attachment. Arrange replacement or specialist inspection for the spring-loaded mechanism.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTravel is smooth but reading has steps or dropouts\u003c\/th\u003e\n\u003ctd\u003eCheck SSI timing, bit format, supply and isolated wiring. Compare several measured distances to the raw word.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse the ordered 3 m sensor on equipment with matching travel, fixing and SSI receiver. Record the cordset, receiver settings and original machine reference.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet travel and zero from the machine drawing and verify the usable movement remains within the rated range. Recheck scaling and direction after fitting. This is a linear reference procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.asm-sensor.com\/files\/asmTheme\/pdf\/asm_posiwire_ws12_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e. WS12 drawings and connections. Use the magnetic SSI section for the exact documented MSSI ordering example.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.asm-sensor.com\/en\/produkt-detail-import-en.html?page=120\u0026amp;prod=18\"\u003eManufacturer reference\u003c\/a\u003e. Match the exact order code or the identified motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.asm-sensor.com\/files\/asmTheme\/pdf\/ws_kat_en.pdf\"\u003eASM POSIWIRE order catalogue\u003c\/a\u003e. See the WS12 MSSI example and decoding of all six options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51126572187813,"sku":"TCG166","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/asm-posiwire-ws12-3000-mssi-draw-wire-sensor-service-guide.jpg?v=1794221572","url":"https:\/\/www.sparefaber.com\/ar\/products\/asm-posiwire-ws12-3000-mssi-draw-wire-sensor","provider":"SpareFaber","version":"1.0","type":"link"}