{"product_id":"balluff-btl070f","title":"Balluff BTL070F 4–20 mA Linear Position Sensor- Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eHydraulic axis reading stuck or scaled incorrectly?\u003c\/strong\u003e SpareFaber can check the BTL070F installation, magnet, S32 cable and PLC current input at your UAE site. Send the sensor and setup details for a bench evaluation with a compatible magnet.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Balluff BTL070F 4–20 mA Linear Position Sensor technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eProvide the sensor code, cylinder or machine drawing, magnet type, PLC channel configuration, current and indicated position at known points. Include symptoms and mounting photos. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a compatible magnet, regulated supply and appropriate analog input or test load to compare measured current with known position. Check the LED status and approved teach settings. A loop calibrator used on the isolated PLC input can separately check the PLC scaling. Exact Mitchell TI-5000JX or TI-3000JX use with this analog linear sensor was not verified. \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_H23_DOK_858412_AA_000.pdf\"\u003eBalluff setup and analog output diagnostics (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eBalluff BTL070F 4–20 mA Linear Position Sensor technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eFind \u003cstrong\u003eBTL070F\u003c\/strong\u003e and \u003cstrong\u003eBTL7-E501-M0200-B-S32\u003c\/strong\u003e. E501 identifies the analog current build, M0200 the 200 mm measuring length, B the rod mounting configuration, and S32 the 8-contact M16 connection. A 200 mm measuring length is distinct from the rod's installation length.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Balluff 200 mm rod and related exact codes\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eBalluff 200 mm rod and related exact codes\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eBalluff ID \/ model\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eStroke and output\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMount or connector difference\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBTL070F · BTL7-E501-M0200-B-S32\u003c\/th\u003e\n\u003ctd\u003e200 mm, 4–20 and 20–4 mA factory output directions\u003c\/td\u003e\n\u003ctd\u003eRod with M18 × 1.5 flange. 8-contact M16 S32.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBTL070E · BTL7-E501-M0150-B-S32\u003c\/th\u003e\n\u003ctd\u003e150 mm, E501 analog current\u003c\/td\u003e\n\u003ctd\u003eSimilar rod and S32 connector. Different measuring length.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBTL1E22 · BTL7-E501-M0200-P-S32\u003c\/th\u003e\n\u003ctd\u003e200 mm, E501 analog current\u003c\/td\u003e\n\u003ctd\u003eProfile design. Use its own mounting and magnet documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/publications.balluff.com\/pdfengine\/pdf?con=en\u0026amp;id=277818\u0026amp;type=pdb\"\u003eBTL070F exact datasheet (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.balluff.com\/en-us\/products\/BTL070E\"\u003eBTL070E exact comparison\u003c\/a\u003e · \u003ca href=\"https:\/\/www.balluff.com\/en-gb\/products\/BTL1E22\"\u003eBTL1E22 profile comparison\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eBalluff publishes the exact BTL070F record and product drawing. Confirm current supply, repair or substitute using the Balluff order code and the complete type. \u003ca href=\"https:\/\/www.balluff.com\/en-us\/products\/BTL070F\"\u003eBalluff exact BTL070F product record\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Balluff BTL070F exact data\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eBalluff BTL070F exact data\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003e200 mm magnetostrictive linear travel. Maximum sampling frequency 4000 Hz per exact sheet. Check settings and magnet arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eM18 × 1.5 threaded flange, Ø10.2 mm protection tube, 290 mm installation length from contact surface. The drawing shows a 30 mm null distance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutputs and supply\u003c\/th\u003e\n\u003ctd\u003eFactory analog output 1 at 4–20 mA, output 2 at 20–4 mA for the documented S32 E501. Supply 10–30 V DC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical connection\u003c\/th\u003e\n\u003ctd\u003eS32 8-contact M16 × 0.75 connector. Use exact E501 S32 column.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePerformance and environment\u003c\/th\u003e\n\u003ctd\u003e±50 µm maximum nonlinearity, ±5 µm repeatability, −40 to +85 °C ambient and IP67 with the connector fitted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/publications.balluff.com\/pdfengine\/pdf?con=en\u0026amp;id=277818\u0026amp;type=pdb\"\u003eExact Balluff dimensions, values and performance (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_H23_DOK_858412_AA_000.pdf\"\u003eBalluff E501 settings and pinout (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eA position magnet moves along the fixed sensing rod. Use the cylinder and Balluff drawings to match the threaded seat, seal, magnet, material and rod support. Check actual insertion and end clearance through the full permitted travel. Measure from the mounting contact surface as specified. A replacement with the same nominal measuring range can still differ in installation length or magnet arrangement. Follow the cylinder OEM procedure for a pressure-boundary installation. \u003ca href=\"https:\/\/publications.balluff.com\/pdfengine\/pdf?con=en\u0026amp;id=277818\u0026amp;type=pdb\"\u003eBTL070F exact installation dimensions (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_H23_DOK_858412_AA_000.pdf\"\u003eBalluff rod, magnet and cylinder installation (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe sensor measures the travel time of a pulse associated with the position magnet and converts position to analog current. The PLC converts that current to machine units. With the default increasing output scaled over an unmodified 200 mm span, 4 mA is one endpoint, 12 mA the midpoint and 20 mA the other endpoint. Actual zero\/endpoints, rising or falling output and invalid-position behavior depend on configuration. Compare current and independent travel before changing a teach setting. \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_H23_DOK_858412_AA_000.pdf\"\u003eBalluff principle, analog behavior and adjustment (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the \u003cstrong\u003eS32 E501\u003c\/strong\u003e assignment in Balluff table 4-2. Read the connector-pin view from the sensor side. The factory KA lead colours in the manual are separate reference information. Check the actual mating cordset.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"BTL7-E501 S32 M16 8-contact wiring\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eBTL7-E501 S32 M16 8-contact wiring\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003eOutput 1, 4–20 mA factory setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003e0 V supply return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eOutput 2, 20–4 mA factory setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003eLa communication \/ programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5\u003c\/th\u003e\n\u003ctd\u003eUnused for E501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e6\u003c\/th\u003e\n\u003ctd\u003eGND per Balluff wiring notes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7\u003c\/th\u003e\n\u003ctd\u003e10–30 V DC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8\u003c\/th\u003e\n\u003ctd\u003eLb communication \/ programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eKeep the output references, programming lines and shield arrangement as the Balluff and PLC diagrams specify. The A501 voltage-output model and the S115 M12 variant have different assignments. \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_H23_DOK_858412_AA_000.pdf\"\u003eBalluff S32 drawing, table 4-2 and wiring notes (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe S32 rod sensor is external to a servo feedback loom. Balluff lists \u003cstrong\u003eBCC00TT\u003c\/strong\u003e straight and \u003cstrong\u003eBCC00UP\u003c\/strong\u003e angled 8-contact M16 mating connectors. The earlier manual lists 5 m molded \u003cstrong\u003eBCC0L21\u003c\/strong\u003e. Confirm exact cordset termination, pressure-system routing and shielding for the installation. Choose the magnet from the approved Balluff and cylinder drawings. \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_H23_DOK_858412_AA_000.pdf\"\u003eBalluff S32 accessories and magnet drawings (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_L19_DOK_858412_03_000.pdf\"\u003eBCC0L21 5 m cable example (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate hydraulic or pneumatic pressure, secure the load, and verify residual energy before disturbing the rod or magnet.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord.\u003c\/strong\u003e Read raw PLC input and machine position at known points under the approved procedure. Capture output choice, teach settings, LED status and what changed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect under isolation.\u003c\/strong\u003e Check connector key and seating, water or oil ingress, rod straightness and magnet retention or travel against the drawing. Verify that the input channel is configured for current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the detached harness.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Use Balluff's pinout and intentional bonds for the reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck voltage and current separately.\u003c\/strong\u003e A qualified technician can use an approved breakout fitted while off, then measure pin 7 to 2 under load in the approved test state. Read current using the verified input or an approved series test connection. Keep the meter's current input out of a supply voltage measurement. Compare current against known movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate faults.\u003c\/strong\u003e If current changes correctly but engineering units are wrong, check input mapping and scaling. If output remains unchanged, check the magnet and teach limits before diagnosing the head. A sensor-side signal that disappears at the PLC points toward the cable or input circuit.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis rod-style magnetostrictive feedback is used for compatible machine-axis or cylinder position measurement. Match range, rod geometry, connection, magnet and output configuration to the machine. The similar profile form has a different mounting arrangement. \u003ca href=\"https:\/\/publications.balluff.com\/pdfengine\/pdf?con=en\u0026amp;id=277818\u0026amp;type=pdb\"\u003eBTL070F exact rod data (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.balluff.com\/en-gb\/products\/BTL1E22\"\u003eBTL1E22 profile form\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eConfirm the mechanical magnet path and authorized cylinder end limits. Record the original output selection, teach points and PLC scale. Set approved endpoints only at known secured positions using the Balluff procedure. Verify both directions and a midpoint before releasing the machine. This measurement uses a linear datum rather than a motor commutation angle. \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_H23_DOK_858412_AA_000.pdf\"\u003eBalluff analog calibration and teach procedure (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/publications.balluff.com\/pdfengine\/pdf?con=en\u0026amp;id=277818\u0026amp;type=pdb\"\u003eBalluff BTL070F exact datasheet (PDF)\u003c\/a\u003e. Installation dimensions, nominal length and operating data.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_H23_DOK_858412_AA_000.pdf\"\u003eBalluff BTL7 A\/E501 rod user guide (PDF)\u003c\/a\u003e. S32 E501 wiring, mounting, outputs and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BTL7_AE501_ABYZ_8_X_L19_DOK_858412_03_000.pdf\"\u003eBalluff BTL7 accessory reference (PDF)\u003c\/a\u003e. Includes the BCC0L21 S32 cable example.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.balluff.com\/en-us\/products\/BTL070F\"\u003eBalluff exact product and downloads\u003c\/a\u003e. Check the full material code and current support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51118280081573,"sku":"TEO34","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/BalluffBTL070F4_20mA.jpg?v=1794119662","url":"https:\/\/www.sparefaber.com\/ar\/products\/balluff-btl070f","provider":"SpareFaber","version":"1.0","type":"link"}