{"product_id":"baumuller-1fli-100m-srs-srm-feedback-feedback-technical-guide","title":"Baumüller 1fLI-100M \/ SRS–SRM feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eBaumüller 1fLI-100M \/ SRS–SRM feedback — Classic HIPERFACE; label-specific ST\/MT. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eBaumüller 1fLI-100M \/ SRS–SRM feedback — motor application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eFull fitted feedback label required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain model \/ application identifier\u003c\/th\u003e\n\u003ctd\u003e1fLI-100M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor order \/ source example\u003c\/th\u003e\n\u003ctd\u003eObtain the complete fitted motor order; the family reference is not an inspected unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eClassic HIPERFACE; label-specific ST\/MT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5063 \/ TI-5104 only after verifying motor connector and encoder voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eConditional TI-5000JX scope. Read the actual SRS50\/60 or SRM50\/60 label; the motor number alone does not identify singleturn versus multiturn. Confirm exact connector view, supply, fixture and installed tester software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5063 \/ TI-5104 only after verifying motor connector and encoder voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eConfirm exact connector view, supply, fixture and installed tester software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eSix-pole Baumüller support only if the fitted encoder and documented lockup convention match; otherwise confirm setup first.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe documented test reference is Baumuller Motors — Identification: 1fLI-100M; P6 SRS\/SRM selections. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eCurrent production status, stock and a verified successor for the exact fitted order remain to confirm with the manufacturer. The linked reference establishes the stated technical scope, not stock or drop-in compatibility. Compare fit, voltage, interface, connector, motor data and alignment before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback technology\u003c\/th\u003e\n\u003ctd\u003eClassic HIPERFACE; label-specific ST\/MT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRetained position\u003c\/th\u003e\n\u003ctd\u003eRead the actual SRS singleturn \/ SRM multiturn label.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor example\u003c\/th\u003e\n\u003ctd\u003e1fLI-100M, spelling retained from Mitchell; verify the nameplate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit \/ service values\u003c\/th\u003e\n\u003ctd\u003eExact shaft\/coupling dimensions, pin map, tightening torque and service ID must match the fitted drawing; unverified values remain open.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eClassic HIPERFACE combines serial identity\/position data with analogue sine\/cosine feedback. Assess both paths independently. Singleturn readings do not prove multiturn retention or correct motor data. This guide does not imply HIPERFACE DSL support.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming shaft datum, locating seat, coupling, retaining cover, fasteners and cable exit before removal. After isolation, inspect accessible looseness, contamination, rubbing and bearing condition. Use the exact outline and service procedure for engagement, rear clearance and fastening. Do not import torque, air gap or coupling dimensions from a similar-looking motor.\u003c\/p\u003e\n\u003cp\u003eMitchell prints the motor example as 1fLI-100M and associates the application with classic HIPERFACE SRS\/SRM feedback. Preserve the printed motor identity until the nameplate is checked. Read the actual SRS50\/60 or SRM50\/60 label to establish singleturn or multiturn operation. Neither the motor number nor the connector alone proves the encoder model, voltage or retained revolution capability.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eSeparate the encoder plug, internal motor loom, bulkhead, machine cable and tester fixture. Verify contact numbering, keying, gender and drawing viewpoint. Identify supply\/return, signal pairs, shield and independent temperature or brake paths from the exact diagram. Unverified pin assignments remain open.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5063 \/ TI-5104 only after verifying motor connector and encoder voltage. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eThe fitted internal loom part number is not established by the motor family or protocol. Record both ends and obtain the motor assembly drawing. Machine cable selection also depends on receiver, length, shielding and fixed\/flexing duty. A Mitchell test lead is not an OEM replacement cable number.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentify the exact assembly\u003c\/th\u003e\n\u003ctd\u003eMitchell prints the motor example as 1fLI-100M and associates the application with classic HIPERFACE SRS\/SRM feedback. Preserve the printed motor identity until the nameplate is checked. Read the actual SRS50\/60 or SRM50\/60 label to establish singleturn or multiturn operation. Neither the motor number nor the connector alone proves the encoder model, voltage or retained revolution capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault with cable movement\u003c\/th\u003e\n\u003ctd\u003eAfter isolation and disconnection at both ends, inspect flex points, pin engagement, moisture and old repairs. Check continuity and unintended shorts against the exact diagram, accounting for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo communication or usable signal\u003c\/th\u003e\n\u003ctd\u003eConfirm the fitted feedback, supported fixture and supply range. A qualified technician can compare source and load voltage with the approved breakout and OEM procedure. Connector shape alone does not establish a safe pin map.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition reads but drive rejects the feedback\u003c\/th\u003e\n\u003ctd\u003eCheck independent signal paths, motor identity, direction, index\/retention and mechanical attachment. Record the original alarm and readable data before changing settings. A reset cannot establish compatible motor data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the original mechanical reference, direction, motor phase convention, retained state and readable data before disturbing the feedback. Use the exact motor procedure for alignment and replacement. Electrical communication alone does not establish machine origin or correct motor\/feedback pairing. Numerical alignment examples must stay with their stated motor, polarity and phase convention.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003e1fLI-100M \/ SRS–SRM feedback. Mitchell prints the motor example as 1fLI-100M and associates the application with classic HIPERFACE SRS\/SRM feedback. Preserve the printed motor identity until the nameplate is checked. Read the actual SRS50\/60 or SRM50\/60 label to establish singleturn or multiturn operation. Neither the motor number nor the connector alone proves the encoder model, voltage or retained revolution capability.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/42345006849435-Baumuller-Motors\" target=\"_blank\" rel=\"noopener\"\u003eBaumuller Motors\u003c\/a\u003e — Identification: 1fLI-100M; P6 SRS\/SRM selections\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eObtain the fitted motor and encoder labels, exact service ID, internal loom\/contact-view drawing and approved fixture. The exact manufacturer PDF remains to obtain; the named Mitchell evidence is linked.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a 1fLI-100M \/ SRS–SRM feedback enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eSix-pole Baumüller support only if the fitted encoder and documented lockup convention match; otherwise confirm setup first. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"related\"\u003e\u003ch2\u003eRelated technical guides\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sparefaber.com\/products\/baumuller-six-pole-sick-srs60-hiperface-feedback\" target=\"_blank\" rel=\"noopener\"\u003eTCG216 — Baumüller SRS60 Six-Pole Servo HIPERFACE Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sparefaber.com\/products\/baum-ller-ds-srm50-srm60-multiturn-feedback-technical-guide\" target=\"_blank\" rel=\"noopener\"\u003eTCG572 — Baumüller DS SRM50 \/ SRM60 multiturn\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51151619293349,"sku":"TCG691","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/baumuller-1fli-100m-srs-srm-feedback-service-guide.jpg?v=1794375199","url":"https:\/\/www.sparefaber.com\/ar\/products\/baumuller-1fli-100m-srs-srm-feedback-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}