{"product_id":"baumuller-ds-hall-commutation-three-phase-ac-tach-feedback","title":"Baumüller DS Hall \/ AC Tach Commutation and Speed Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eIdentify the DS motor with Hall commutation and a three-phase AC tachometer before selecting a test lead. The Hall channels and the tachometer tell the drive different things, so test each path separately.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Baumüller DS Hall \/ AC Tach Commutation and Speed Feedback technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Use the stated Hall-state and tach test paths. Compare the AC tach response separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Mitchell describes Generic Pulse 120° for the correctly matched and aligned assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e TI-5071 on the documented plug. Verify connector revision before matching the fixture.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eBaumüller DS Hall \/ AC Tach Commutation and Speed Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDS Hall \/ AC tach with 17-contact M23\u003c\/th\u003e\n\u003ctd\u003eMitchell lists TI-5071 and the TI-5105 module for the documented test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDS Hall \/ tach with 15-contact Heavymate D\u003c\/th\u003e\n\u003ctd\u003eSeparate TI-5729 connector branch with TI-5105 in the index.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDS resolver\u003c\/th\u003e\n\u003ctd\u003eThe Mitchell index lists a separate 12-contact resolver branch. Check the full order before selecting the fixture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommutation\u003c\/th\u003e\n\u003ctd\u003eThree Hall state channels, H1 to H3 in the Mitchell article.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed feedback\u003c\/th\u003e\n\u003ctd\u003eThree-phase AC tachometer on the scoped DS build.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest display\u003c\/th\u003e\n\u003ctd\u003eMitchell uses Generic Incremental to display Hall states.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eHall states identify rotor sectors. The AC tachometer provides a speed-related signal. Compare the Hall sequence and the tachometer response independently and record the test direction and motor order.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eRecord the housing and tachometer reference before dismantling. Mitchell discusses a possible keyed relationship for the illustrated assembly. Verify the actual fit from the matched drawing before assuming the key sets its reference.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the exact TI-5071 or TI-5729 wiring reference as applicable, with the matching motor schematic. Identify the Hall circuits, their supply, the three tach conductors and the separate motor power connection.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eCheck the motor connector and cable retention before removing the feedback assembly. An original DS internal harness and the shop test adapter have different functions. Record the actual plug and full motor type for a spare.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor commutation fault with tach output\u003c\/th\u003e\n\u003ctd\u003eCheck Hall states and phase reference on the correct fixture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHall transitions present with speed error\u003c\/th\u003e\n\u003ctd\u003eCheck tach winding continuity under isolation and the expected tach waveform on an approved setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal drops when the plug is moved\u003c\/th\u003e\n\u003ctd\u003eInspect and isolate-test the correct M23 or Heavymate harness.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eMitchell provides a scope relationship for the documented Hall\/tach assembly. Confirm phase, direction and tachometer reference with that drawing and the actual motor. Back-driving a motor for waveform checks requires the approved guarded specialist setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eBaumüller DS with documented Hall\/tach option\u003c\/p\u003e\n\u003cp\u003eTrace a commutation fault separately from missing speed feedback and choose the actual DS plug.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/ar\/products\/baumuller-six-pole-sick-srs60-hiperface-feedback\"\u003eBaumüller SRS60 Six-Pole Servo HIPERFACE Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ar\/products\/baumuller-dsg-56m-ecn-1313-endat-feedback\"\u003eBaumüller DSG 56M HEIDENHAIN ECN 1313 EnDat Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4405085285915-Baumuller-motors-with-Halls-commutation-and-3-phase-AC-Tacho-feedback\"\u003eBaumüller motors with Hall commutation and three-phase AC tach feedback\u003c\/a\u003e. Hall and AC tach feedback, TI-5071 \/ TI-5105 and test\/run section\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell Test Cable Index by Manufacturer\u003c\/a\u003e. Supplementary reference for the stated model or setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.dropbox.com\/s\/zo07yov6f08z3m7\/TI5071.pdf?dl=0\"\u003eMitchell TI-5071 test lead drawing\u003c\/a\u003e. 17-contact M23 lead for the documented DS configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51134499127461,"sku":"TCG329","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/baumuller-ds-hall-commutation-three-phase-ac-tach-feedback-service-guide.jpg?v=1794298078","url":"https:\/\/www.sparefaber.com\/ar\/products\/baumuller-ds-hall-commutation-three-phase-ac-tach-feedback","provider":"SpareFaber","version":"1.0","type":"link"}