{"product_id":"br-8lsaa2-d8045s000-3-hybrid-endat","title":"B\u0026R 8LSAA2.D8045S000-3 Hybrid EnDat22 Motor Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for 8LSAA2.D8045S000-3 feedback diagnosis and installation checks, and send-in evaluation where the fitted device and test setup are confirmed.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"B\u0026amp;R 8LSAA2.D8045S000-3 Hybrid EnDat22 Motor Feedback technical guide\"\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Mitchell documents the hybrid connection and cautions about incomplete memory decoding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Exact motor run setup open\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eB\u0026amp;R 8LSAA2.D8045S000-3 Hybrid EnDat22 Motor Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8LSAA2.D8045S000-3\u003c\/th\u003e\n\u003ctd\u003eExact B\u0026amp;R single-cable motor order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eECI 1119 FS\u003c\/th\u003e\n\u003ctd\u003eB\u0026amp;R names this inductive singleturn EnDat22 encoder family for the order. Record the fitted encoder ID.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eS0 \/ S1 \/ S2 \/ S3\u003c\/th\u003e\n\u003ctd\u003eHybrid connector option examples in Mitchell’s 8LS article. Match the complete order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data for 8LSAA2.D8045S000-3\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eReference data for 8LSAA2.D8045S000-3\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor configuration\u003c\/th\u003e\n\u003ctd\u003eB\u0026amp;R lists a single-cable connection and five motor pole pairs for the reference order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback\u003c\/th\u003e\n\u003ctd\u003eECI 1119 FS EnDat22 inductive singleturn feedback on this exact B\u0026amp;R motor order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHybrid signals\u003c\/th\u003e\n\u003ctd\u003eMitchell describes the serial connection without incremental 1 Vpp A\/B through this connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the B\u0026amp;R order and OEM motor outline to confirm the shaft, connector clearance and mounting. Obtain the full fitted encoder ID and approved installation procedure before disturbing the inductive gap or the feedback safety configuration.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe hybrid cable carries motor power and a separate EnDat link in the same assembly. Verify communications independently from motor windings and cable power. Line Levels testing does not apply to the omitted A\/B signals on the hybrid connection.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eMitchell’s hybrid connector figure identifies the feedback path. Verify the exact motor view and isolate motor power before connecting the tester. Use the corresponding encoder diagram for direct access.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eTI-5786 mates with the documented 8LS hybrid connection. TI-5668 or TI-5079 may apply when connecting directly to a matched encoder. Verify the installed hybrid cable assembly with B\u0026amp;R.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore inspection.\u003c\/strong\u003e Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive sees motor power but no encoder\u003c\/th\u003e\n\u003ctd\u003eCheck the serial path within the hybrid cable and the exact drive and motor code.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReported memory angle conflicts with incoming measurements\u003c\/th\u003e\n\u003ctd\u003eRetain the original file and physical measurements. Verify the OEM commissioning procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback reads after fitting but the drive faults\u003c\/th\u003e\n\u003ctd\u003eCheck approved gap, reference, mounting and safety validation separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003e8LSAA2.D8045S000-3 Check the exact ID, drive and connector before applying an installation or test procedure.\u003c\/p\u003e\n\u003cp\u003eIdentify the hybrid path and check the exact motor memory rules. Keep this application distinct from the existing ECI 1119 device guide.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCapture the incoming alignment and memory before removal. Mitchell flags incompletely decoded memory fields on the newer hybrid series. Use the OEM service and safety validation procedure for the installed drive and feedback option.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4415336973723-B-R-8LS-Motors-with-Hybrid-Connector\"\u003eB\u0026amp;R 8LS hybrid guide\u003c\/a\u003e. Article body. S options, TI-5786 and memory interpretation.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.br-automation.com\/de\/produkte\/antriebstechnik\/synchronmotoren-8ls\/standardmotoren-8lsa-3-kurzfristig-verfuegbar\/8lsaa2d8045s000-3\/\"\u003eB\u0026amp;R 8LSAA2.D8045S000-3 product record\u003c\/a\u003e. Motor data, single-cable connection and exact encoder family.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51127098966181,"sku":"TCG183","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/br-8lsaa2-d8045s000-3-hybrid-endat-service-guide.jpg?v=1794236310","url":"https:\/\/www.sparefaber.com\/ar\/products\/br-8lsaa2-d8045s000-3-hybrid-endat","provider":"SpareFaber","version":"1.0","type":"link"}