{"product_id":"broadcom-aeat-8800-q24-magnetic-ic","title":"Broadcom AEAT-8800-Q24 Magnetic Encoder IC | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for AEAT-8800-Q24 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Broadcom AEAT-8800-Q24 Magnetic Encoder IC technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse the documented host circuit or manufacturer evaluation arrangement to observe SSI, PWM or the configured outputs and compare them to known angles. Mitchell motor-feedback support for this bare IC is unconfirmed. Select a board-level fixture with the correct logic and supply.\u003c\/p\u003e\n\u003ch2\u003eBroadcom AEAT-8800-Q24 Magnetic Encoder IC technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eAEAT-8800-Q24\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAEAT-8800-Q24\u003c\/th\u003e\n\u003ctd\u003e5 × 5 mm QFN-24 board-level device with an exposed ground pad.\u003c\/td\u003e\n\u003ctd\u003eConfigurable absolute SSI\/PWM and incremental or commutation outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAEAT-8000 family\u003c\/th\u003e\n\u003ctd\u003eRelated magnetic sensing products. Confirm complete package and marking.\u003c\/td\u003e\n\u003ctd\u003eCompare electrical mode, pinout and programming from the exact datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for AEAT-8800-Q24\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for AEAT-8800-Q24\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute output\u003c\/th\u003e\n\u003ctd\u003eProgrammable 10 to 16-bit absolute resolution, depending on mode and configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOther outputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable ABI and UVW options. Pin 24 can be W or PWM according to mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended operating supply\u003c\/th\u003e\n\u003ctd\u003e3.0–3.6 V in 3.3 V operation or 4.5–5.5 V in 5 V operation. Confirm board configuration and datasheet conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit\u003c\/th\u003e\n\u003ctd\u003eQFN-24, nominal 5 × 5 mm. Magnet geometry and spacing come from the Broadcom application diagram and the host assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/docs.broadcom.com\/doc\/pub-005892\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe chip is soldered to the host PCB. Its Hall system reads a rotating magnet centered and aligned to the package. Check the board mounting and magnet position for eccentricity, tilt or movement. Follow the Broadcom placement drawing and the equipment OEM for assembly tolerances and soldering.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe chip converts magnetic angle into a digital word. In SSI mode the host clocks a position read. The board may instead use PWM or selected incremental or commutation outputs. Determine which mode and logic level the board uses. A wrong mode can look like a bad sensor even when the magnet and supply are healthy.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eFollow the package pin-1 and exposed-pad view in the datasheet. These are IC contacts. Use the host board’s schematic for external connectors and do not assign a standard motor connector from these numbers.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Selected AEAT-8800-Q24 pins from Broadcom Figure 4\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSelected AEAT-8800-Q24 pins from Broadcom Figure 4\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact or group\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e14 and 19\u003c\/th\u003e\n\u003ctd\u003eVDDA supply inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e13, 20 and exposed pad 25\u003c\/th\u003e\n\u003ctd\u003eVSS ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e10 \/ 11 \/ 12\u003c\/th\u003e\n\u003ctd\u003eClock \/ SSI NSL or SPI input \/ data output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e21\u003c\/th\u003e\n\u003ctd\u003eSSI\/SPI selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7 \/ 8 \/ 9\u003c\/th\u003e\n\u003ctd\u003eI \/ B \/ A in ABI mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e22 \/ 23 \/ 24\u003c\/th\u003e\n\u003ctd\u003eU \/ V \/ W in UVW mode. 24 can serve PWM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe host PCB sets the connection to the outside machine. Use the board drawing to trace power, reference and selected signal lines to any local connector. Get the actual motor or machine harness number from the assembly label. An industrial SSI cable assumes the board provides a matching interface.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoard inspection.\u003c\/strong\u003e Keep the host board de-energized and observe ESD controls. Inspect the package, connector and magnet before probing, and use the board schematic to identify test points.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAngle is noisy once per revolution\u003c\/th\u003e\n\u003ctd\u003eCheck magnet centering, gap and board movement with the approved setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHost sees no SSI data\u003c\/th\u003e\n\u003ctd\u003eVerify configured supply, host clock and select, mode and routing to the correct output pin.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReplacement board has a consistent angular offset\u003c\/th\u003e\n\u003ctd\u003eVerify the installed magnet orientation and read original configuration with the OEM-approved method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can use the approved host-board test setup to verify the configured supply, logic signals and magnet response. Isolate the board before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis part is an IC for the documented host-board circuit. Match the actual PCB part and revision, magnet and configured logic interface. Repair or replacement at board level needs the OEM’s calibration and configuration information.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCheck the magnet center and mechanical zero before changing electronic settings. Record available original configuration using the approved board process. OTP settings require the manufacturer’s specific programming conditions and should be handled by a qualified technician after confirming the intended values.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/docs.broadcom.com\/doc\/pub-005892\"\u003eMain technical PDF\u003c\/a\u003e. Broadcom exact part datasheet. Pin assignment, electrical conditions, magnet placement and interface configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.broadcom.com\/products\/motion-control-encoders\/absolute-encoders\/single-turn-encoders\/aeat-8800-q24\"\u003eManufacturer reference\u003c\/a\u003e. Match the exact order code or the identified motor option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51125882421413,"sku":"TCG141","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/broadcom-aeat-8800-q24-magnetic-ic-service-guide.jpg?v=1794215880","url":"https:\/\/www.sparefaber.com\/ar\/products\/broadcom-aeat-8800-q24-magnetic-ic","provider":"SpareFaber","version":"1.0","type":"link"}