{"product_id":"broadcom-heds-5540-a11","title":"Broadcom HEDS-5540#A11 Optical Incremental Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for HEDS-5540 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Broadcom HEDS-5540#A11 Optical Incremental Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eAn approved low-voltage fixture with the documented pull-ups can check 500 cycles\/rev, quadrature, index and repeatability through a known turn. Inspect the connector and hub before using a different receiver. Exact Mitchell support remains unverified.\u003c\/p\u003e\n\u003ch2\u003eBroadcom HEDS-5540#A11 Optical Incremental Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eHEDS-5540#A11\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHEDS-5540#A11\u003c\/th\u003e\n\u003ctd\u003eStandard housing, 4 mm motor shaft hub. Align the base and hub per Broadcom.\u003c\/td\u003e\n\u003ctd\u003e500 CPR, A\/B quadrature plus index, 5 V nominal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHEDS-5540#A05\u003c\/th\u003e\n\u003ctd\u003e3\/16 in shaft hub, per ordering key. Same family mounting concept.\u003c\/td\u003e\n\u003ctd\u003e500 CPR and index. Check shaft fit before choosing this code.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHEDS-5500#A06\u003c\/th\u003e\n\u003ctd\u003e1\/4 in shaft hub, per ordering key.\u003c\/td\u003e\n\u003ctd\u003eTwo-channel series. The pin used for index on HEDS-5540 is unused on HEDS-5500.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eDigiKey identifies the exact A11 code as active in its product record. Confirm Broadcom production and lead time for the exact code before sourcing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for HEDS-5540#A11\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for HEDS-5540#A11\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder code\u003c\/th\u003e\n\u003ctd\u003eHEDS-5540 three-channel optical encoder. A specifies 500 CPR and 11 specifies a 4 mm shaft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e4.5–5.5 V DC at recommended conditions. Ripple under 100 mV peak-to-peak.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal\u003c\/th\u003e\n\u003ctd\u003eA, B and index I. 2.7 kΩ pull-ups per Broadcom Figure 1. One TTL load per output as shown.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCount frequency\u003c\/th\u003e\n\u003ctd\u003e100 kHz guaranteed under the documented conditions. Check the speed and assembly tolerances for the application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/docs.broadcom.com\/doc\/AV02-1046EN\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the HEDS-5540 three-channel assembly sequence in AV02-1046EN. Align the base using the specified locating pins or HEDS-8910 alignment tool as applicable. Use the 4 mm hub on its specified shaft projection and ensure access for the hub screw. Check for rubbing or damage before power-up. Use the datasheet's set screw instruction and tool size for this assembly.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eA transmissive optical codewheel interrupts light as the shaft turns. The electronics generate A and B quadrature plus one index per turn. The receiver reconstructs relative movement by counting, and uses index to establish reference. The output circuit requires the specified pull-ups.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the pin-1 marking on the HEDS-5540 body and Figure 1 or Figure 5. This is the five-contact three-channel version.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"HEDS-5540 contacts\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eHEDS-5540 contacts\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSignal\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003eIndex I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eChannel A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003e+5 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5\u003c\/th\u003e\n\u003ctd\u003eChannel B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe datasheet shows 2.7 kΩ pull-ups to +5 V at the outputs. Verify the actual receiver loading and pin numbering before power is applied.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eBroadcom lists HEDS-8903 for the three-channel five-wire lead and gives Molex 0050579405 and 0016020097 for the single-ended cable connector hardware. HEDS-8902 is the two-channel lead and lacks the index conductor. Check the actual harness and the equipment-side connector independently.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo pulses or a low logic level\u003c\/th\u003e\n\u003ctd\u003eVerify supply, return and the required pull-ups. Confirm the hub rotates without contact.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCounts intermittent after remounting\u003c\/th\u003e\n\u003ctd\u003eCheck hub fit, base centering, shaft play and any evidence of codewheel damage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA\/B present, index absent\u003c\/th\u003e\n\u003ctd\u003eCheck pin 2 and the HEDS-8903 conductor, then test the index output under the documented load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse on compact motor or machine assemblies with a compatible 5 V TTL incremental receiver and correct shaft. Keep the installation clean and protected as required. The exact motor and controller determine any further setup.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThe HEDS-8910 procedure aligns the encoder to the motor shaft. The machine establishes its own index-based origin and direction. For motor commutation, follow the equipment manufacturer's procedure for that motor and feedback option.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/docs.broadcom.com\/doc\/AV02-1046EN\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.broadcom.com\/products\/motion-control-encoders\/incremental-encoders\/transmissive-encoders\/heds-5540a05\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/docs.broadcom.com\/doc\/AV02-1046EN#page=5\"\u003eRecommended operating conditions and pull-ups\u003c\/a\u003e. Use the three-channel circuit, including Figure 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/docs.broadcom.com\/doc\/AV02-1046EN#page=9\"\u003eMounting and assembly\u003c\/a\u003e. Shows the alignment tool and hub procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/docs.broadcom.com\/doc\/AV02-1046EN#page=10\"\u003eMating lead and connector\u003c\/a\u003e. Figure 5 shows the HEDS-8903.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/docs.broadcom.com\/doc\/AV02-1046EN#page=11\"\u003eOrdering information\u003c\/a\u003e. Decodes the A11 options.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.digikey.com\/en\/products\/detail\/broadcom-limited\/HEDS-5540-A11\/2219708\"\u003eExact A11 product record\u003c\/a\u003e. Distributor corroborates the order code and configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118434877605,"sku":"TCG71","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/BroadcomHEDS-5540_A11.jpg?v=1794130453","url":"https:\/\/www.sparefaber.com\/ar\/products\/broadcom-heds-5540-a11","provider":"SpareFaber","version":"1.0","type":"link"}