{"product_id":"fanuc-aia1000-a860-2000-t301","title":"FANUC αiA1000 A860-2000-T301 Pulsecoder  | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eFANUC feedback alarm or lost reference after motor work?\u003c\/strong\u003e SpareFaber can visit your UAE site to check the αi Pulsecoder, coupling, cable and amplifier diagnostics. Ask about bench diagnosis of the exact motor and original feedback.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"FANUC αiA1000 A860-2000-T301 Pulsecoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the complete A06B motor order code and A860 encoder label, CNC or amplifier model, alarm number and connector photos. Record whether the fault started after a collision, cable flex, encoder replacement or a battery warning. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell documents \u003cstrong\u003eTI-5000JX\u003c\/strong\u003e testing for supported FANUC serial Pulsecoders. With the correct profile and cable, check serial count and direction, alarm\/status and commutation display. Its \u003cstrong\u003eTI-3000JX\u003c\/strong\u003e run manual lists \u003cstrong\u003eP* Alphai\u003c\/strong\u003e with the \u003cstrong\u003eTI-5047\u003c\/strong\u003e feedback lead. Confirm the exact motor and current software. Use a secured, guarded fixture and verify the commutation pattern and phase reference before allowing rotation. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26604473824539-Fanuc-Motors\"\u003eMitchell FANUC bench testing\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26605474038811-Fanuc-Motors\"\u003eMitchell αi run-test method and lead\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eFANUC αiA1000 A860-2000-T301 Pulsecoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead the complete \u003cstrong\u003eA860\u003c\/strong\u003e number and the motor’s \u003cstrong\u003eA06B\u003c\/strong\u003e number. αiA1000 is the absolute serial type that FANUC specifies at one million divisions per revolution. Use the complete suffix to select the housing and sealing version.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"FANUC B-65285EN αi Pulsecoder replacement codes\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eFANUC B-65285EN αi Pulsecoder replacement codes\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePart number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFeedback class\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOrder distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA860-2000-T301\u003c\/th\u003e\n\u003ctd\u003eαiA1000 absolute serial, 1,000,000 divisions\/rev\u003c\/td\u003e\n\u003ctd\u003eStandard specification for the documented A06B-02xx motor order group.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA860-2000-T321\u003c\/th\u003e\n\u003ctd\u003eαiA1000 absolute serial, 1,000,000 divisions\/rev\u003c\/td\u003e\n\u003ctd\u003eIP67 specification in the FANUC replacement table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA860-2005-T301\u003c\/th\u003e\n\u003ctd\u003eαiI1000, incremental-class serial\u003c\/td\u003e\n\u003ctd\u003eSame division count with different retention behavior.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA860-2001-T301\u003c\/th\u003e\n\u003ctd\u003eαiA16000 absolute serial, 16,000,000 divisions\/rev\u003c\/td\u003e\n\u003ctd\u003eDifferent resolution and controller configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eMatch the motor and encoder together, including the sealing variant and connector. \u003ca href=\"https:\/\/www.mroelectric.com\/static\/application\/product\/pdfs\/A20B-2101-0390.pdf\"\u003eFANUC αi ordering specifications (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.mroelectric.com\/static\/app\/product\/pdfs\/A06B-0061-B203-0100.pdf\"\u003eFANUC Pulsecoder division counts (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eFANUC’s maintenance manual lists T301 and T321 as replacement order numbers for the documented motors. Current production and availability for the exact A860 suffix require FANUC confirmation. Reviewed 7 November 2026. \u003ca href=\"https:\/\/www.mroelectric.com\/static\/application\/product\/pdfs\/A20B-2101-0390.pdf\"\u003eFANUC replacement part list (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"αiA1000 reference T301, FANUC descriptions and maintenance\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eαiA1000 reference T301, FANUC descriptions and maintenance\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue \/ scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eMotor-mounted absolute serial Pulsecoder. 1,000,000 divisions per motor revolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply functions\u003c\/th\u003e\n\u003ctd\u003eThe αiA1000 connector drawing identifies +5 V main power and a separate +6 V backup contact. Follow the exact amplifier and battery specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial connection\u003c\/th\u003e\n\u003ctd\u003e10-contact JAE JN2AS10UL1-R motor receptacle in the documented αi series.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical connection\u003c\/th\u003e\n\u003ctd\u003eOldham coupling and motor pocket with O-ring on the documented αi assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironmental and speed limits\u003c\/th\u003e\n\u003ctd\u003eUse the motor’s service and outline data. The IP67 variant is T321 in the documented list.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.mroelectric.com\/static\/app\/product\/pdfs\/A06B-0061-B203-0100.pdf\"\u003eFANUC B-65262EN\/06 section 8.1, Pulsecoder specifications (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe Pulsecoder fits in the rear motor pocket. An Oldham coupling transfers shaft rotation to it. FANUC’s illustrated assembly uses four M4 fixing bolts and a seated O-ring. During authorized service, use the motor’s correct coupling orientation and engage the teeth before seating the housing. The adjacent cover screws are separate. Check for damaged coupling teeth, a pinched O-ring and debris in the seat. Do not force the Pulsecoder into the pocket.\u003c\/p\u003e\n\u003cp\u003eFANUC lists \u003cstrong\u003eA290-0501-V535\u003c\/strong\u003e as the Oldham coupling for the documented A06B-02 motor group. Obtain the exact motor’s approved fastener and commissioning instructions before internal service. \u003ca href=\"https:\/\/www.mroelectric.com\/static\/app\/product\/pdfs\/A06B-6150-H075.pdf\"\u003eFANUC B-65285EN\/03 sections 1.4–1.5, coupling and assembly (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.mroelectric.com\/static\/application\/product\/pdfs\/A20B-2101-0390.pdf\"\u003eFANUC αi replacement tables (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe amplifier receives digital position and alarm information on the complementary RD pair. The αiA1000 has a separate backup circuit for absolute position retention. It is possible to have a valid serial link but lose the machine’s absolute reference after feedback or battery work. Read alarms and verify the CNC reference separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"FANUC αiA1000 motor receptacle, B-65262EN\/06 section 8.1\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eFANUC αiA1000 motor receptacle, B-65262EN\/06 section 8.1\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConnector pin(s)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8 and 9\u003c\/th\u003e\n\u003ctd\u003e+5 V main supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7 and 10\u003c\/th\u003e\n\u003ctd\u003e0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e6 \/ 5\u003c\/th\u003e\n\u003ctd\u003eRD \/ complementary RD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eFrame ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003e+6 V backup contact on the documented absolute configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the connector view for the keyed motor receptacle and the separate amplifier diagram for the cable end. Keep unassigned contacts clear and use the OEM battery arrangement. This table does not give a universal CNC connector map. \u003ca href=\"https:\/\/www.mroelectric.com\/static\/app\/product\/pdfs\/A06B-0061-B203-0100.pdf\"\u003eFANUC motor-side connector view and signals (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Verified FANUC connector and specialist lead examples\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eVerified FANUC connector and specialist lead examples\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePart or kit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRole\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJN2DS10SL1-R\u003c\/th\u003e\n\u003ctd\u003eJAE straight mating plug in the αi connector list, for the documented cable diameter range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJN2DS10SL2-R\u003c\/th\u003e\n\u003ctd\u003eJAE straight mating option for the larger cable diameter in the same list.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJN2FS10SL1-R \/ JN2FS10SL2-R\u003c\/th\u003e\n\u003ctd\u003eRight-angle mating options. Confirm cable diameter and clearance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5047\u003c\/th\u003e\n\u003ctd\u003eMitchell αi bench feedback lead. Match the tester profile and motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe machine feedback cable connects the motor receptacle to the matched amplifier. Obtain the CNC or machine builder’s cable assembly number and end-to-end diagram before making a replacement. The FANUC connector kits above are components. The internal Pulsecoder assembly is ordered by the exact A860 part. \u003ca href=\"https:\/\/www.mroelectric.com\/static\/app\/product\/pdfs\/A06B-0061-B203-0100.pdf\"\u003eFANUC αi signal connector ordering and cable drawings (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26605474038811-Fanuc-Motors\"\u003eMitchell bench lead\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePreserve the CNC reference before disturbing the feedback.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Account for the separate absolute backup supply under the OEM procedure.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check plug engagement, damaged pins, contamination, coolant ingress and cable strain. If the alarm began after a rebuild, inspect the coupling and seating under the authorized motor procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the isolated cable.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Verify any parallel power conductors and the separate backup route in the actual wiring diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure and compare.\u003c\/strong\u003e A qualified technician can use the approved breakout fitted while off to verify nominal +5 V between the documented supply and return contacts. Check backup at the OEM test point, with the specified battery arrangement. Read alarms and serial state using the FANUC system or compatible tester.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse the symptom.\u003c\/strong\u003e No serial data after a cable change calls for power, return and RD checks. Valid position with a lost datum calls for backup and reference checks. Faults synchronized with shaft motion after replacement call for inspecting the coupling and commissioned direction.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eFANUC documents T301 for standard αiA1000 configurations in the \u003cstrong\u003eA06B-02aa-Bcc0\u003c\/strong\u003e motor group and T321 for the IP67 group shown in the replacement table. The αiS 8\/4000 is in the \u003cstrong\u003eA06B-0235-Bxxx\u003c\/strong\u003e motor family. Confirm the entire motor suffix and its replacement table before applying the example. \u003ca href=\"https:\/\/www.mroelectric.com\/static\/application\/product\/pdfs\/A20B-2101-0390.pdf\"\u003eFANUC exact motor group and replacement codes (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.mroelectric.com\/static\/app\/product\/pdfs\/A06B-0061-B203-0100.pdf\"\u003eFANUC motor ordering specifications (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThe coupling’s physical orientation, the motor commutation reference and the CNC absolute machine datum are separate checks. Preserve the incoming reference and configuration before removal. Mitchell’s documented guarded αi verification uses the +U\/−V and +U\/−W phase references and compares the commutation pattern. Use the exact motor and FANUC commissioning procedure for replacement and any reference return. Obtain the motor-specific procedure rather than assuming a fixed angle from T301.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mroelectric.com\/static\/app\/product\/pdfs\/A06B-0061-B203-0100.pdf\"\u003eFANUC B-65262EN\/06 αi motor descriptions (PDF)\u003c\/a\u003e. Section 8.1 for resolution and motor-side signals. Appendix on αi signal connectors for mating parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mroelectric.com\/static\/application\/product\/pdfs\/A20B-2101-0390.pdf\"\u003eFANUC B-65285EN\/04 αi maintenance manual (PDF)\u003c\/a\u003e. See Pulsecoder replacement, ordering and battery instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mroelectric.com\/static\/app\/product\/pdfs\/A06B-6150-H075.pdf\"\u003eFANUC B-65285EN\/03 maintenance manual (PDF)\u003c\/a\u003e. Sections 1.4–1.5 illustrate coupling orientation and the O-ring seat.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26605474038811-Fanuc-Motors\"\u003eMitchell FANUC run-test reference\u003c\/a\u003e. Check the αi selection, cable and guarded verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51117230653605,"sku":"TXG09","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/FANUC_iA1000A860-2000-T301Pulsecoder.jpg?v=1794145497","url":"https:\/\/www.sparefaber.com\/ar\/products\/fanuc-aia1000-a860-2000-t301","provider":"SpareFaber","version":"1.0","type":"link"}