{"product_id":"georgii-kobold-ksy-q-rc-rj-rf-sin-cos-feedback-technical-guide","title":"Georgii Kobold KSY-Q RC \/ RJ \/ RF sin\/cos 1 Vpp incremental and commutation | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eGeorgii Kobold KSY-Q RC \/ RJ \/ RF sin\/cos — 1 Vpp incremental and commutation. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eGeorgii Kobold KSY-Q RC \/ RJ \/ RF sin\/cos — Motor application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eERN1185 \/ ERN1387\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer MPN \/ full suffix\u003c\/th\u003e\n\u003ctd\u003eKSY-Q RC \/ RJ \/ RF sin\/cos is the scoped family\/designation. Match every additional character on the fitted label before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM service ID \/ motor order\u003c\/th\u003e\n\u003ctd\u003eNot established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003e1 Vpp incremental and commutation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented starting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5090 direct plus TI-5101 on the verified analogue setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial distinction\u003c\/th\u003e\n\u003ctd\u003eKSY-Q resolver, HIPERFACE and EnDat guides do not cover these analogue\/index paths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eConditional bench scope: Compare ERN1185 512\/2,048-period choices with ERN1387 and inspect C\/D commutation separately. Exact fixture, supply and drawing must agree before connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5090 direct plus TI-5101 on the verified analogue setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eMatch exact profile, supply, connector and installed software. A named cable is not a complete test procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eNo complete motor-run approval for every fitted configuration. Verify motor order, poles, power\/brake wiring, phase direction, alignment and installed TI-3000JX profile.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe admission evidence is Georgii Kobold Motors — KSY-Q Encoder Systems, RC\/RJ\/RF. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eCurrent production status, exact-order stock and an approved successor have not been confirmed in the cited evidence. Retain the installed label and ask for an exact-order check before selecting a replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRC\u003c\/th\u003e\n\u003ctd\u003eERN1185, 512 analogue periods\/revolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRJ\u003c\/th\u003e\n\u003ctd\u003eERN1185, 2,048 analogue periods\/revolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRF\u003c\/th\u003e\n\u003ctd\u003eERN1387, 2,048 analogue periods\/revolution, with the separate commutation-track requirement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ output compatibility\u003c\/th\u003e\n\u003ctd\u003eUse the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact dimensions, torque and pins\u003c\/th\u003e\n\u003ctd\u003eUse the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThese options use analogue sine\/cosine tracks. Count physical periods separately from any interpolation or decoded counts. Reference and C\/D commutation information need their own assessment. Use the documented analogue fixture and the exact motor connection drawing; a serial device menu does not test these paths.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003ePhotograph the incoming shaft\/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model.\u003c\/p\u003e\n\u003cp\u003eKSY-Q RC and RJ use ERN1185 at 512 and 2,048 periods respectively; RF uses ERN1387 at 2,048 periods. Their analogue position, reference and commutation paths must be checked separately. A serial EnDat profile is not the correct acquisition method for this branch.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eMap five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive\/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5090 direct plus TI-5101 on the verified analogue setup. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eNo internal OEM harness number or universal extension has been verified for this exact fitted order. Obtain the motor assembly drawing and photograph both loom ends before sourcing it. A fixed installation cable and a cable-carrier extension may have different flex and shielding requirements. Do not convert the Mitchell test-lead number into an OEM replacement part number.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration-specific check\u003c\/th\u003e\n\u003ctd\u003eKSY-Q RC and RJ use ERN1185 at 512 and 2,048 periods respectively; RF uses ERN1387 at 2,048 periods. Their analogue position, reference and commutation paths must be checked separately. A serial EnDat profile is not the correct acquisition method for this branch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault appears when the machine cable moves\u003c\/th\u003e\n\u003ctd\u003eWith the system isolated and both ends disconnected, inspect flex points, connector engagement and repaired sections. Check end-to-end continuity and unintended shorts against the actual pin map, accounting for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo feedback or intermittent loss at the drive\u003c\/th\u003e\n\u003ctd\u003eAfter label and fixture verification, have a qualified technician check the specified supply or excitation through an approved breakout. Compare at the source and load under the OEM procedure; never assume a voltage from the connector shell.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWrong direction, count or reference position\u003c\/th\u003e\n\u003ctd\u003eCompare A\/B ordering, the selected decoding factor and the fitted pulse rating. Verify reference and commutation paths independently; do not swap wires experimentally on an energized servo.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming mechanical datum, direction and motor phase convention before disturbing the sensor. No numerical commutation angle or universal memory image is specified here. A motor-specific alignment requires the exact motor data, supported equipment setup and applicable OEM procedure. Preserve any recoverable offset, identity and parameter data before changes; establish hardware and data compatibility before a specialist transfer or write. Incremental A\/B position alone does not retain a machine origin through power loss. Homing\/reference strategy and any separate Hall\/UVW alignment must be established with the machine builder.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eKSY-Q RC \/ RJ \/ RF sin\/cos. KSY-Q resolver, HIPERFACE and EnDat guides do not cover these analogue\/index paths.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/41443030327195-Georgii-Kobold-Motors\" target=\"_blank\" rel=\"noopener\"\u003eGeorgii Kobold Motors\u003c\/a\u003e — KSY-Q Encoder Systems, RC\/RJ\/RF\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.georgiikobold.de\/uploads\/pics\/ksy_q_221144_090316_02.pdf\" target=\"_blank\" rel=\"noopener\"\u003eGeorgii Kobold ksyq motor catalogue\u003c\/a\u003e — Manufacturer technical document; use the named feedback option and exact frame\/order. Historical revisions do not prove present availability or fitted-unit interchangeability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePrimary family\/application PDF linked; exact fitted order, fixture, internal loom and alignment evidence remain to confirm.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a KSY-Q RC \/ RJ \/ RF sin\/cos enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eNo complete motor-run approval for every fitted configuration. Verify motor order, poles, power\/brake wiring, phase direction, alignment and installed TI-3000JX profile. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51144103559333,"sku":"TCG513","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/georgii-kobold-ksy-q-rc-rj-rf-sin-cos-service-guide.jpg?v=1794326925","url":"https:\/\/www.sparefaber.com\/ar\/products\/georgii-kobold-ksy-q-rc-rj-rf-sin-cos-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}