{"product_id":"heidenhain-eci-1319","title":"HEIDENHAIN ECI 1319 EnDat22 Encoder |  | Technical Guide| Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeedback trouble after an encoder or bearing change?\u003c\/strong\u003e SpareFaber can visit your UAE site to check ECI 1319 wiring, rotor seating, flange clamping and drive feedback, and assist with installation and alignment verification.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"HEIDENHAIN ECI 1319 EnDat22 Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder label and complete motor order code, drive model, alarms and the work done just before the fault. For bench diagnosis of a clearance or commutation problem, keep the motor, original encoder and mating loom together. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA compatible \u003cstrong\u003eMitchell TI-5000JX\u003c\/strong\u003e EnDat setup can compare serial position, direction and communication on the correct profile and lead. Confirm the current software profile for this ID. The 810661-02 has digital feedback. For mechanical installation, HEIDENHAIN lists the \u003cstrong\u003ePWM 21 with ATS mounting interface\u003c\/strong\u003e for the 810661-xx family. Check mounting quality through that documented workflow in addition to reading serial position.\u003c\/p\u003e\n\u003cp\u003eMitchell describes a \u003cstrong\u003eTI-3000JX Generic EnDat RunSer\u003c\/strong\u003e method for supported motors. Confirm the motor profile and fixture before using it. Any run test requires verified motor phase order, pole count, direction and commutation, with the motor secured and guarded. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26653326767387-Heidenhain-Serial-Encoders\"\u003eMitchell EnDat test reference\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26656224782235-Generic-Endat\"\u003eMitchell serial run-test setup\u003c\/a\u003e · \u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_Encoders_for_Servo_Drives_ID208922_en.pdf#page=35\"\u003eHEIDENHAIN mounting interface (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eHEIDENHAIN ECI 1319 EnDat22 Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead the complete ID and its suffix, then record the motor and drive order codes. This guide focuses on \u003cstrong\u003e810661-02\u003c\/strong\u003e and the documented 810661-xx EnDat22 family. HEIDENHAIN also uses ECI 1319 on an EnDat 3 product sheet. Compare the interface before applying a wiring table.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"ECI 1319 full IDs in HEIDENHAIN 1000353, September 2022\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eECI 1319 full IDs in HEIDENHAIN 1000353, September 2022\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFull ID\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eShaft and flange\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical \/ order details\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e810661-02\u003c\/th\u003e\n\u003ctd\u003e44C Ø12.7 mm blind bore, 0YA flange\u003c\/td\u003e\n\u003ctd\u003eEnDat22 singleturn, keyed 12+4-pin PCB, D533166\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e810661-03\u003c\/th\u003e\n\u003ctd\u003e44A Ø12 mm blind bore, 0YA flange\u003c\/td\u003e\n\u003ctd\u003eEnDat22 singleturn, same document family. Check the smaller mating shaft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e810661-06\u003c\/th\u003e\n\u003ctd\u003e44C Ø12.7 mm blind bore, 0YA flange\u003c\/td\u003e\n\u003ctd\u003eEnDat22 singleturn. Manufacturer lists this ID in a collective package.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe alternative \u003cstrong\u003eEnDat 3 E30-R2\u003c\/strong\u003e product sheet has a different electrical interface. Use the exact ID sheet and hardware configuration for the unit in hand. \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/ECI1319_EQI1331_EBI1335_FS_ID1000353_05_A_02_en.pdf#page=3\"\u003eEnDat22 ID table (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Produktinformationen\/PI_ECI1319_EQI1331_ID1303979_en.pdf\"\u003eSeparate EnDat 3 product information (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eHEIDENHAIN provides a current catalogue record for 810661-02. Exact-ID production, stock and last-time-buy status require confirmation from the manufacturer. Reviewed 7 November 2026. \u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/810661-02\"\u003e810661-02 catalogue record\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"810661-02, exact catalogue and EnDat22 product data\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003e810661-02, exact catalogue and EnDat22 product data\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented value\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eInductive absolute singleturn, without integral bearing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition and accuracy\u003c\/th\u003e\n\u003ctd\u003e524,288 binary values per turn (19 bits), ±65 arcseconds system accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e3.6–14 V DC at encoder. Typical 95 mA at 5 V without load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum power\u003c\/th\u003e\n\u003ctd\u003e650 mW at 3.6 V and 700 mW at 14 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial timing\u003c\/th\u003e\n\u003ctd\u003eCalculation time ≤5 µs, encoder clock limit ≤16 MHz, cable and receiver may lower the usable clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical speed and axial motion\u003c\/th\u003e\n\u003ctd\u003e≤15,000 rpm encoder limit. Permissible axial motion ±0.5 mm per the 1000353 specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical interface\u003c\/th\u003e\n\u003ctd\u003e0YA flange, 44C Ø12.7 mm blind bore. IP20, −40 to +115 °C operating temperature.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the tighter limit of the encoder, motor and drive. Functional safety depends on the complete installed system, safety-rated evaluation and the documented mechanical assembly. \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/ECI1319_EQI1331_EBI1335_FS_ID1000353_05_A_02_en.pdf#page=3\"\u003eElectrical specifications (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/ECI1319_EQI1331_EBI1335_FS_ID1000353_05_A_02_en.pdf#page=4\"\u003eMechanical specifications (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe motor bearings locate the rotor. Seat the rotor’s blind bore on the prepared motor shaft shoulder, and seat the 0YA stator flange on the motor register and flange face. The central screw retains the rotor. Three axial screws secure the stator. Check both contact faces for burrs, debris, witness marks and fretting before reassembly. Bearing float can move the rotor relative to the stator even if the connector is sound.\u003c\/p\u003e\n\u003cp\u003eThe 1000353 drawing specifies a DIN 6912 M5×30–08.8–MKL central screw at \u003cstrong\u003e5 N·m, +0.5 N·m\u003c\/strong\u003e, and ISO 4762 M4×10–8.8–MKL flange screws at \u003cstrong\u003e2 ±0.1 N·m\u003c\/strong\u003e for the illustrated 0YA assembly. Confirm the fasteners, locking features, mating dimensions and final OEM procedure on your motor. The drawing has a separate access plug. Keep its specification distinct from the rotor screw. \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/ECI1319_EQI1331_EBI1335_FS_ID1000353_05_A_02_en.pdf#page=2\"\u003eMating dimensions and fasteners (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/ECI1319_without_housing_EnDat22_0YA_FS_ba_1388764_Ver00_01_mu.pdf\"\u003eECI 1319 EnDat22 operating instructions (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUse the mounting interface after a bearing or encoder replacement.\u003c\/strong\u003e Serial position can be readable even when the mounting clearance is near a limit. HEIDENHAIN’s mounting table lists a mounting interface for 810661-xx and a separate ExI wizard for certain other IDs. Verify a full revolution under the OEM-approved diagnostic procedure. \u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_Encoders_for_Servo_Drives_ID208922_en.pdf#page=35\"\u003eMounting diagnostics and supported IDs (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe inductive sensor encodes the shaft position within one revolution. The receiver drives the differential CLOCK pair. It uses the bidirectional DATA pair for commands and replies, including position and protocol integrity checks. This exact EnDat22 type has serial position and status, with no A\/B analog position pair. A singleturn position wraps once per mechanical revolution. The drive or machine must track travel across turns if the application requires it.\u003c\/p\u003e\n\u003cp\u003eThe optional external temperature sensor uses its own contacts at the encoder, separate from the serial pairs. The receiver and installed harness determine which temperature information is available. A valid serial reply, good mounting clearance and good motor commutation are separate checks.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe table follows the EnDat22 ECI\/EQI drawing in 1000353. Use the manufacturer connector view and housing key to locate the a\/b rows. The M23 column applies to the documented HEIDENHAIN 9-pin SpeedTEC connection, after matching the harness at both ends.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"810661-02 PCB D533166 and documented EnDat22 M23 assignments\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003e810661-02 PCB D533166 and documented EnDat22 M23 assignments\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePCB\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e9-pin M23\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUₚ \/ 0 V\u003c\/th\u003e\n\u003ctd\u003e1b \/ 4b\u003c\/td\u003e\n\u003ctd\u003e3 \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply sense \/ return sense\u003c\/th\u003e\n\u003ctd\u003e6a \/ 3a\u003c\/td\u003e\n\u003ctd\u003e7 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDATA \/ complement\u003c\/th\u003e\n\u003ctd\u003e6b \/ 1a\u003c\/td\u003e\n\u003ctd\u003e5 \/ 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCLOCK \/ complement\u003c\/th\u003e\n\u003ctd\u003e2b \/ 5a\u003c\/td\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal sensor T+ \/ T−\u003c\/th\u003e\n\u003ctd\u003e8a \/ 8b in 4-pin section\u003c\/td\u003e\n\u003ctd\u003eSeparate routing. No allocation in this feedback table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eKeep unused contacts vacant and use the specified housing shield bond. Obtain the OEM drawing for other motor connectors and drive ends. HEIDENHAIN specifies completely assembled qualified cables for safety-related use. \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/ECI1319_EQI1331_EBI1335_FS_ID1000353_05_A_02_en.pdf#page=7\"\u003eEnDat22 ECI\/EQI pin drawing (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Verified cables from HEIDENHAIN 1000353\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eVerified cables from HEIDENHAIN 1000353\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEndpoints and role\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1120948-xx\u003c\/th\u003e\n\u003ctd\u003eIn-motor 16-pin PCB to 9-pin M23 SpeedTEC angled flange socket. Confirm length and external sensor routing for the exact motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e745796-xx\u003c\/th\u003e\n\u003ctd\u003eExternal lead from 9-pin M23 female to 8-pin M12 male coupling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e524599-xx\u003c\/th\u003e\n\u003ctd\u003eExternal 8-pin M12 female to 15-pin D-sub male adapter. Verify tester or receiver compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe listed internal lead is for the HEIDENHAIN connection in the drawing. For a different OEM harness, read its label and confirm both endpoint maps, strain relief and shield before ordering. Use the approved assembled lead on a safety axis. \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/ECI1319_EQI1331_EBI1335_FS_ID1000353_05_A_02_en.pdf#page=6\"\u003eCables and adapters (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore opening the motor.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check the locking PCB plug, motor bulkhead, pin retention, oil or debris, crushed conductors and cable support. Look for loose rotor retention, uneven flange contact and signs of bearing movement before adjusting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity and shorts.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower under load.\u003c\/strong\u003e With an approved breakout fitted while off, a qualified technician can measure DC supply from PCB 1b to 4b on the documented unit. Compare the drive’s specified voltage at its output and at the encoder. A drop across a loaded harness can reveal a connection defect that an unloaded meter misses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate the symptoms.\u003c\/strong\u003e A missing serial reply points first to supply, protocol selection or clock\/data wiring. Intermittency after shaft or bearing work calls for mechanical inspection and mounting diagnostics. Stable position with a torque or safety alarm calls for checking the drive configuration, safety commissioning and motor angle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThe 0YA\/44C assembly is an internal motor feedback option. An exact OEM motor using 810661-02 was not verified for this guide. Beckhoff’s AX5000 hardware reference distinguishes pure-digital EnDat 2.2 on its AX572x option from analog-assisted EnDat configurations. Its ECI 1319 table also lists an analog-assisted version. Match the exact drive hardware and the encoder label before applying that example. \u003ca href=\"https:\/\/infosys.beckhoff.com\/content\/1033\/ax5000_system_doku_hw2\/644606603.html\"\u003eBeckhoff AX5000 EnDat feedback configurations\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThe 0YA mounting clearance locates the sensor relative to the rotor. The motor’s commutation angle relates the reported position to the motor phase reference. Record the incoming drive settings and OEM-approved offset or memory before removal, if the equipment supports reading it. Restore only approved motor-specific data to a compatible replacement, then read it back and verify direction, physical alignment and drive commissioning. The encoder ID by itself supplies no fixed motor angle.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/ECI1319_EQI1331_EBI1335_FS_ID1000353_05_A_02_en.pdf\"\u003eHEIDENHAIN 1000353, EnDat22 product information (PDF)\u003c\/a\u003e. Pages 2–4 for fit and specifications, 6 for the leads and 7 for ECI\/EQI wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/ECI1319_without_housing_EnDat22_0YA_FS_ba_1388764_Ver00_01_mu.pdf\"\u003eHEIDENHAIN 1388764 operating instructions (PDF)\u003c\/a\u003e. 0YA \/ 44C EnDat22 functional-safety assembly. If a direct download redirects, request the number from HEIDENHAIN.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_Encoders_for_Servo_Drives_ID208922_en.pdf\"\u003eHEIDENHAIN Encoders for Servo Drives, 208922 (PDF)\u003c\/a\u003e. See 810661-xx and the mounting-interface compatibility table.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/810661-02\"\u003e810661-02 exact catalogue record\u003c\/a\u003e. Catalogue downloads include the exact pin-layout number D533166.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51116960383141,"sku":"drg56","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/HEIDENHAINECI1319EnDat22.jpg?v=1794125538","url":"https:\/\/www.sparefaber.com\/ar\/products\/heidenhain-eci-1319","provider":"SpareFaber","version":"1.0","type":"link"}