{"product_id":"heidenhain-ecn-1113-803427-01-endat01-encoder","title":"HEIDENHAIN ECN 1113 803427-01 EnDat01 Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for ECN 1113 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"HEIDENHAIN ECN 1113 803427-01 EnDat01 Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eFeedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eAn EnDat-capable bench can read identification and stable position and evaluate the analog tracks where the fixture supports them. Mitchell documents the ECN 1113 family on TI-5000JX with TI-5668 for direct connection. A powered TI-3000JX run needs a separately verified motor setup.\u003c\/p\u003e\n\u003ch2\u003eHEIDENHAIN ECN 1113 803427-01 EnDat01 Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003e803427-01\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cp\u003eManufacturer device order code\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eECN 1113 · 803427-01\u003c\/th\u003e\n\u003ctd\u003e1KA 6 mm blind hollow shaft and 75A recessed face coupling.\u003c\/td\u003e\n\u003ctd\u003eSingleturn EnDat01 and 512 analog periods per turn. Double-row R8 PCB plug.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEQN 1125 · 803428-01\u003c\/th\u003e\n\u003ctd\u003eRelated ECN\/EQN 1100 mounting family. Check the exact drawing.\u003c\/td\u003e\n\u003ctd\u003eAdds multiturn position. A similar plug and signal class do not establish replacement compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eECN 1123 · 803429-01\u003c\/th\u003e\n\u003ctd\u003eRelated 1100 family. Verify the motor mating drawing.\u003c\/td\u003e\n\u003ctd\u003eEnDat22 without the ECN 1113 analog track output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for 803427-01\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for 803427-01\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute positions\u003c\/th\u003e\n\u003ctd\u003e8,192 per revolution, singleturn, binary.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncremental output\u003c\/th\u003e\n\u003ctd\u003e512 sin\/cos periods per revolution, nominal 1 Vpp. −3 dB cutoff 190 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e3.6–14 V DC at the encoder, exact ID product record.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCoupling and bore\u003c\/th\u003e\n\u003ctd\u003e75A, M3 on Ø43 mm pitch circle. 1KA Ø6 mm axial-fastened blind hollow shaft with a 2 mm drive lug protruding 2.6 mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector and environment\u003c\/th\u003e\n\u003ctd\u003eStraight double-row 15-contact R8, map D533387. IP40. Operating −40 to +115 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_Encoders_for_Servo_Drives_ID208922_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eInspect the motor pilot, drive lug, shaft end and coupling face for burrs, fretting and signs of slip. The lug locates the rotor and the flexible stator coupling restrains the housing while accommodating the specified movement.\u003c\/p\u003e\n\u003cp\u003eUse the mating drawing for the 1KA and 75A combination and the motor service instructions for the fastener, preload and tightening sequence. Avoid using the stator screws to pull a reluctant rotor into place.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe receiver reads absolute position over the EnDat clock and data lines. The paired analog tracks also let compatible electronics interpolate motion between the 512 periods.\u003c\/p\u003e\n\u003cp\u003eIf the drive can read position but reports loss of speed feedback, check whether it uses the analog tracks. If the analog tracks look plausible but absolute position cannot be read, trace the clock and data path separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eAt the 15-contact R8 device header use HEIDENHAIN map D533387 as indexed by 803427-01. Match the drawing view and key before identifying supply and return, clock pair, data pair and the two analog pairs.\u003c\/p\u003e\n\u003cp\u003eThe published product page identifies the map but its direct download currently redirects. Obtain the map or the motor builder’s verified connector drawing before probing individual contacts. The motor bulkhead has its own map.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eHEIDENHAIN lists 606079-01 and 605090-xx in the ECN 1113 \/ EQN 1125 JAE output-cable catalogue. These are catalogue assemblies for the documented topology. Match the R8 termination, length and motor bulkhead to the machine drawing.\u003c\/p\u003e\n\u003cp\u003eMitchell lists TI-5668 at the encoder for the ECN 1113 and EQN 1125 in its MOOG coverage. Identify the connector on the motor before selecting the separate motor-side lead.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition is present but unstable while moving\u003c\/th\u003e\n\u003ctd\u003eCheck both analog pairs using the approved receiver or differential measurement. Inspect the lead restraint and shaft seating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo serial response with clean analog tracks\u003c\/th\u003e\n\u003ctd\u003eCheck the receiver’s EnDat mode, the clock\/data path and supply at the correct ends.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback changes after remounting\u003c\/th\u003e\n\u003ctd\u003eCheck lug seating, stator coupling and the original motor commutation reference before enabling motion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMitchell identifies ECN 1113 on some MOOG servo motors. Record the full MOOG motor order and drive feedback option before using that example. The HEIDENHAIN ID alone does not establish which motor is fitted.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the original rotor-to-encoder relationship and capture supported OEM position data before removal. Re-establish the motor-specific commutation reference by the manufacturer’s procedure. There is no universal ECN 1113 angle.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_Encoders_for_Servo_Drives_ID208922_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e. ECN 1100 series comparison and mating geometry. Use the exact ID page for the 803427-01 configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/803427-01\"\u003eManufacturer reference\u003c\/a\u003e. Match the exact order code or the identified motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/48944747309339-MOOG-Motors\"\u003eMitchell MOOG motor guide\u003c\/a\u003e. Documents ECN 1113 and the direct TI-5668 lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_Cables_and_Connectors_ID1206103_en.pdf\"\u003eHEIDENHAIN cable catalogue\u003c\/a\u003e. See the EnDat01 output-cable table for ECN 1113 (JAE).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/803428-01\"\u003eEQN 1125 803428-01\u003c\/a\u003e. Check the multiturn comparison.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/803429-01\"\u003eECN 1123 803429-01\u003c\/a\u003e. Check the distinct EnDat22 version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51126566486181,"sku":"TCG147","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/heidenhain-ecn-1113-803427-01-endat01-encoder-service-guide.jpg?v=1794220936","url":"https:\/\/www.sparefaber.com\/ar\/products\/heidenhain-ecn-1113-803427-01-endat01-encoder","provider":"SpareFaber","version":"1.0","type":"link"}