{"product_id":"heidenhain-ern-1387","title":"HEIDENHAIN ERN 1387 Encoder | Service \u0026 Technical Guide | Book UAE Location Factory Visit- Service\/Align","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eNeed an engineer on site for an ERN 1387 fault?\u003c\/strong\u003e SpareFaber offers field visits to troubleshoot the encoder, feedback cable and drive. We can install a replacement encoder and check or restore its commutation alignment using the motor manufacturer’s procedure.\u003c\/p\u003e\n\u003cp\u003eOn supported setups, we use the Mitchell TI-5000JX to check the 1 Vpp A\/B signals, reference pulse and C\/D commutation track. If your encoder or Encoder Fitted Servo motor is Not Working, Behaving Erratically or unreliably then ask about and Order a bench evaluation and a TI-3000JX run test for a compatible motor assembly.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest an on-site visit or bench test\u003c\/a\u003e \u003ca href=\"#identify\"\u003eGo to encoder IDs and wiring\u003c\/a\u003e \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eVisits are available for AbuDhabi, Dubai, Ajman Sharjah, Ras Al Khaima, Fuairah and Al Ain.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"ERN 1387 technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eOrder an on-site visit or bench evaluation of Heidenhain ERN1387?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRequest an on-site diagnosis\u003c\/strong\u003e when the fault occurs only in the machine or the encoder, wiring and drive need to be checked together. Include the encoder ID, motor order code, drive model, fault code and when the fault occurs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest bench evaluation\u003c\/strong\u003e if the encoder or motor is already out. Describe any work already done and have label and connector photos ready for follow-up. Ask for packing and shipping instructions before dispatching it. Keep the coupling and spacers identified with the original assembly.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eSend an ERN 1387 service enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eTesting of Heidenhain ERN 1387 at your Site. What can be tested with Mitchell equipment ?\u003c\/h2\u003e\n\u003ch3\u003eTI-5000JX · Encoder bench test\u003c\/h3\u003e\n\u003cp\u003eMitchell documents the ERN 1387 under \u003cstrong\u003eGeneric Incremental\u003c\/strong\u003e with the \u003cstrong\u003eTI-5101\u003c\/strong\u003e 1 Vpp adapter. Use the \u003cstrong\u003eTI-5090\u003c\/strong\u003e on the matching direct encoder connector or the \u003cstrong\u003eTI-5010\u003c\/strong\u003e on the documented Siemens motor feedback connection. Verify the exact cable and motor connector before testing. Mitchell calls for TI-5101 DIP switch 1 \u003cstrong\u003eclosed\u003c\/strong\u003e to select the C\/D channels in the software. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4409340233371-Siemens-motors-with-Heidenhain-ERN1387-or-Hengstler-S21-RS53-encoders\"\u003eMitchell’s ERN 1387 procedure\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\" role=\"region\" aria-label=\"TI-5000JX test coverage\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eWhat the bench tests tell you\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTest\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to look for\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA\/B motion and R index\u003c\/th\u003e\n\u003ctd\u003eIn Normal Commutation, check that the count changes consistently with direction, totals \u003cstrong\u003e8,192 quadrature counts per mechanical revolution\u003c\/strong\u003e from 2,048 signal cycles, and detects the R reference mark (called Z in Mitchell’s software).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eC\/D commutation track\u003c\/th\u003e\n\u003ctd\u003eIn Sin\/Cos Commutation, check the differential levels and angle progression at the test angles in Mitchell’s guide. C and D each complete one cycle per mechanical turn and are about 90° apart.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog signal quality\u003c\/th\u003e\n\u003ctd\u003eUse Mitchell’s 1 Vpp line-level method and the specified termination to check A\/B differential amplitude. The generic square-wave line-level check is intended for TTL\/HTL. For intermittent dropouts, a properly terminated differential scope measurement can capture what a steady meter reading misses.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlignment on a motor\u003c\/th\u003e\n\u003ctd\u003eCompare the index-based angle in Normal Commutation with the exact motor’s alignment reference using the OEM procedure. A loose encoder on the bench can verify its outputs. Motor alignment requires the assembled motor and its reference. \u003ca href=\"#alignment\"\u003eSee the Siemens bench targets and OEM check\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eTI-3000JX · Can it run the motor?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eYes, for compatible motor assemblies.\u003c\/strong\u003e Mitchell documents a run test for some Siemens \u003cstrong\u003e1FT6, 1FK6, 1FT7 and 1FK7\u003c\/strong\u003e motors fitted with this type of incremental feedback. The documented setup uses \u003cstrong\u003eGeneric Incremental\u003c\/strong\u003e, the \u003cstrong\u003eTI-5010\u003c\/strong\u003e feedback cable and the \u003cstrong\u003eTI-5101\u003c\/strong\u003e adapter with both DIP switches \u003cstrong\u003eopen\u003c\/strong\u003e so it passes A\/B\/Z. Confirm the full motor order code, feedback and power cables, and compatible servo amplifier before applying that setup. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/42346415920027-Siemens-Motors\"\u003eMitchell’s Siemens run-test setup\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eVerify the encoder signals and motor alignment on the TI-5000JX first. The TI-3000JX run test then checks rotation, direction and speed stability of the assembled motor on a guarded, secured bench. A smooth bench run leaves OEM-drive compatibility and intermittent feedback faults to be checked separately. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/36991527055003-Always-Test-with-the-TI-5000JX-Before-the-TI-3000JX-Run-Test\"\u003eMitchell’s run-test limits and test sequence\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eKnowledge BASE for ERN1387 Encoder; Data, Specifications, Dimensions, Mounting, Dismantling procedure, Manuals etc. \u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eShop-floor reference · Incremental rotary encoder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ERN 1387 gives the drive two kinds of feedback. Its A\/B tracks report motion, while its once-per-revolution C\/D tracks help the drive establish rotor position for commutation. If a drive reports a feedback fault, check the full encoder ID and the cable before ordering a replacement.\u003c\/p\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my ID\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eOn-machine checks\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eMitchell testing\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment angles\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind the ID on your label\u003c\/h2\u003e\n\u003cp\u003eRecord the full HEIDENHAIN ID, including the suffix, and the full motor and drive model codes. The mounting and supplied hardware can differ by ID.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\" role=\"region\" aria-label=\"Searchable encoder ID comparison\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eDocumented ERN 1387 configurations\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eHEIDENHAIN ID\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eStator mounting\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSupplied hardware\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eListed output\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/749144-01\"\u003e749144-01\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eType 06 expanding ring, Ø65 mm motor-side mating bore\u003c\/td\u003e\n\u003ctd\u003eMounting kit with M5×50 and M5×47 screws\u003c\/td\u003e\n\u003ctd\u003e≈1 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/749144-05\"\u003e749144-05\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eType 06 expanding ring, Ø65 mm motor-side mating bore\u003c\/td\u003e\n\u003ctd\u003eEncoder exchange kit\u003c\/td\u003e\n\u003ctd\u003e≈1 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"#specifications\"\u003e749146-xx\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003ePlane-surface stator coupling for elevator servo drives\u003c\/td\u003e\n\u003ctd\u003eConfirm the supplied hardware for your full ID\u003c\/td\u003e\n\u003ctd\u003e≈1 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/749147-02\"\u003e749147-02\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eSupplied without a coupling\u003c\/td\u003e\n\u003ctd\u003eSpacer plates and central screw\u003c\/td\u003e\n\u003ctd\u003e≈1.05 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eShared by 749144-01, 749144-05 and 749147-02.\u003c\/strong\u003e 2,048 lines per revolution, an additional one-cycle sine\/cosine track, nominal 5 V DC supply (±5%), IP40, a listed operating range of −40 to +120 °C, and a locking straight two-row 14-pin plug with configuration D319274. HEIDENHAIN lists a 210 kHz (−3 dB) cutoff on both 749144 records. Check the exact record for any other ID.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFind an ID quickly.\u003c\/strong\u003e Search the full ID in the table. If your label begins with 749146, search \u003cstrong\u003e749146\u003c\/strong\u003e to find the family entry. The \u003cstrong\u003exx\u003c\/strong\u003e stands for the suffix on your label.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore buying a substitute.\u003c\/strong\u003e Compare the taper, stator attachment, connector and pin assignment, included hardware, and the motor maker’s approved feedback and alignment requirements. The shared electrical layout alone cannot establish interchangeability. If your ID is absent, look it up on HEIDENHAIN’s site or send a clear label photo with the motor nameplate.\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eCurrent production and end-of-life status\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm by full HEIDENHAIN ID.\u003c\/strong\u003e As of 7 November 2026, public manufacturer sources confirm documentation for several ERN 1387 IDs, including an April 2025 product sheet for \u003cstrong\u003e749144-58\u003c\/strong\u003e. Current production and end-of-life status are unconfirmed. Ask HEIDENHAIN or the motor maker whether your full ID is available as new production, a service spare or an approved successor. \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/ECN1313_ERN1326_ERN1387_Kundenspezifisch_ID1460370_en.pdf#page=5\"\u003eHEIDENHAIN product information 1460370 (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.heidenhain.com\/service\/technical-support\"\u003eHEIDENHAIN support\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eERN 1387 specifications\u003c\/h2\u003e\n\u003cp\u003eThese specifications apply to \u003cstrong\u003eID 749146-xx\u003c\/strong\u003e, the ERN 1387 with a plane-surface stator coupling for elevator servo drives. For other IDs, use the matching product record and motor documentation.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Produktinformationen\/PI_ECN1313_ECN1325_ERN1387_Elevator_Drive_Control_ID1085677_en.pdf#page=3\"\u003eHEIDENHAIN product information 1085677, page 3 (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Produktinformationen\/PI_ECN1313_ECN1325_ERN1387_Elevator_Drive_Control_ID1085677_en.pdf#page=2\"\u003e749146-xx mounting drawing, page 2 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\" role=\"region\" aria-label=\"Specifications for ERN 1387 ID 749146-xx\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eHEIDENHAIN ERN 1387 · ID 749146-xx\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eManufacturer specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncremental output\u003c\/th\u003e\n\u003ctd\u003eApprox. 1 Vpp analog sine\/cosine (A and B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLine count and system accuracy\u003c\/th\u003e\n\u003ctd\u003e2,048 lines per revolution. System accuracy ±20 arcseconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommutation track (Z1)\u003c\/th\u003e\n\u003ctd\u003eOne sine cycle and one cosine cycle per revolution (C and D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference mark (R)\u003c\/th\u003e\n\u003ctd\u003eOne per revolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCutoff frequency (−3 dB)\u003c\/th\u003e\n\u003ctd\u003e≥210 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder connection\u003c\/th\u003e\n\u003ctd\u003e14-pin PCB connector. See the \u003ca href=\"#wiring\"\u003epin assignments\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDC supply\u003c\/th\u003e\n\u003ctd\u003e5 V ±0.25 V (4.75–5.25 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent draw\u003c\/th\u003e\n\u003ctd\u003e≤130 mA without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStator coupling\u003c\/th\u003e\n\u003ctd\u003ePlane-surface coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft geometry\u003c\/th\u003e\n\u003ctd\u003eØ9.25 mm tapered shaft, 1:10 taper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical speed limit\u003c\/th\u003e\n\u003ctd\u003e2,000 rpm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft starting torque\u003c\/th\u003e\n\u003ctd\u003e≤0.01 N·m at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRotor inertia\u003c\/th\u003e\n\u003ctd\u003e2.6 × 10\u003csup\u003e−6\u003c\/sup\u003e kg·m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAxial allowance of measured shaft\u003c\/th\u003e\n\u003ctd\u003e±1.5 mm for mounting tolerance and thermal expansion only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRadial runout of measured shaft\u003c\/th\u003e\n\u003ctd\u003e0.13 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVibration (55–2,000 Hz)\u003c\/th\u003e\n\u003ctd\u003e≤300 m\/s² through +100 °C. ≤150 m\/s² above +100 °C through +120 °C. EN 60068-2-6.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShock (6 ms)\u003c\/th\u003e\n\u003ctd\u003e≤2,000 m\/s². EN 60068-2-27.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−40 to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress protection\u003c\/th\u003e\n\u003ctd\u003eIP40 when mounted (EN 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMass\u003c\/th\u003e\n\u003ctd\u003eApprox. 0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eHow Heidenhain ERN 1387 mounts - installation | Dimension Details\u003c\/h2\u003e\n\u003cp\u003eIDs 749144-01, 749144-05 and 749147-02 use HEIDENHAIN’s 65B shaft with a 1:10 taper and 9.25 mm functional diameter. That dimension describes the taper geometry. Use the mating drawing for the actual seat dimensions and tolerances. The product records also list M10 and M6 back-off threads. On the 749144 variants, the shaft locates on the motor’s tapered seat and the expanding ring restrains the encoder body in the motor-side bore. For 749147-02, confirm the motor’s coupling arrangement before ordering or dismantling.\u003c\/p\u003e\n\u003cp\u003eThe linked 65B\/06 drawing calls out a Ø65 mm mating bore with +0.10\/0 mm tolerance. That is a bore dimension on the documented configuration. Match the drawing revision to the supplied unit before using it for fit, extraction or screw selection.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/ERN_1381_1387_65B_1073758-91.pdf\"\u003e749147-02 mounting sheet for ERN 1387.035 (PDF)\u003c\/a\u003e. If the link shows HEIDENHAIN’s download maintenance notice, use document number 1073758-91 when requesting a copy.\u003c\/p\u003e\n\u003cp\u003eBefore removal, record the cable routing, spacer stack and existing installation with photographs. Use the applicable motor and encoder instructions to select the extraction method, hardware and tightening sequence. If the old unit has already moved on its taper, its witness marks cannot establish the correct commutation angle. Use the motor maker’s commissioning procedure after replacement or any suspected movement.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/ERN_1387_65B07B_37D_1033640-91.pdf\"\u003eHEIDENHAIN 65B\/06 drawing and mounting instructions (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/749147-02\"\u003e749147-02 record with its own mounting-document listing\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface · How the ERN 1387 sends feedback to the drive\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring method:\u003c\/strong\u003e incremental. \u003cstrong\u003eInterface:\u003c\/strong\u003e analog sinusoidal incremental voltage signals, nominally \u003cstrong\u003e1 Vpp\u003c\/strong\u003e. The drive powers the encoder and reads the changing voltages as the shaft turns.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\/B track.\u003c\/strong\u003e The versions documented here produce 2,048 sine\/cosine cycles per mechanical turn. A and B are a quarter-cycle apart. The drive uses their order for direction, their frequency for speed and their relative voltages to estimate position within each cycle. That last step is interpolation. The receiver determines the effective measuring step.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR reference mark.\u003c\/strong\u003e A once-per-turn reference lets the drive identify a repeatable shaft position as it passes the mark.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC\/D commutation track (Z1).\u003c\/strong\u003e One sine cycle and one cosine cycle per shaft revolution give a compatible drive the coarse rotor angle it uses for commutation, including at standstill. Machine position is established by the machine’s referencing procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOn a test bench.\u003c\/strong\u003e Vpp is the peak-to-peak signal swing. HEIDENHAIN characterizes A and B across each differential pair at a 120 Ω termination, with the specified supply at the encoder. Compare a differential scope reading with the exact ID’s data and the approved test setup. A DC supply reading tells you about the power feed. Evaluating signal quality requires observing the waveforms.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_Interfaces_ID1078628_en.pdf#page=18\"\u003eHEIDENHAIN encoder interfaces, 1 Vpp signals and interpolation (PDF)\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eERN 1387 connector pin assignments\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eWiring, Pin Out and signal checks for Heidenhain ERN 1387 \u003c\/h2\u003e\n\u003cp\u003eUse it for Signal checking, manufacturing Cable, ordering Cables\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMatch the connector before probing.\u003c\/strong\u003e The PCB column uses the manufacturer’s lettered positions for the 14-pin encoder connector. Identify row letters, latch and viewing side from the \u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Produktinformationen\/PI_ECN1313_ECN1325_ERN1387_Elevator_Drive_Control_ID1085677_en.pdf#page=5\"\u003econnector illustration on PDF page 5\u003c\/a\u003e. The M23 column describes HEIDENHAIN’s documented 17-pin cable\/flange arrangement. Use your motor maker’s connector drawing at the motor and drive ends, where the assignment can differ.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\" role=\"region\" aria-label=\"Connector pin assignments\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eERN 1387 pin assignments by connector\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e14-pin encoder PCB\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHEIDENHAIN 17-pin M23\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply U\u003csub\u003eP\u003c\/sub\u003e \/ 0 V\u003c\/th\u003e\n\u003ctd\u003e1b \/ 5b\u003c\/td\u003e\n\u003ctd\u003e7 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSense U\u003csub\u003eP\u003c\/sub\u003e \/ sense 0 V\u003c\/th\u003e\n\u003ctd\u003e7a \/ 3a\u003c\/td\u003e\n\u003ctd\u003e1 \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA+ \/ A−\u003c\/th\u003e\n\u003ctd\u003e6b \/ 2a\u003c\/td\u003e\n\u003ctd\u003e15 \/ 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eB+ \/ B−\u003c\/th\u003e\n\u003ctd\u003e3b \/ 5a\u003c\/td\u003e\n\u003ctd\u003e12 \/ 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference R+ \/ R−\u003c\/th\u003e\n\u003ctd\u003e4b \/ 4a\u003c\/td\u003e\n\u003ctd\u003e3 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommutation C+ \/ C−\u003c\/th\u003e\n\u003ctd\u003e7b \/ 1a\u003c\/td\u003e\n\u003ctd\u003e14 \/ 17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommutation D+ \/ D−\u003c\/th\u003e\n\u003ctd\u003e2b \/ 6a\u003c\/td\u003e\n\u003ctd\u003e9 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal shield\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature T+ \/ T−, where fitted in the documented internal motor cable\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e5 \/ 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eHEIDENHAIN shows each sense lead tied internally to its corresponding supply rail. Disconnect the encoder for cable-only continuity testing so those internal links are excluded. Cable shield bonding follows the applicable assembly drawing. Keep spare contacts vacant and identify wires by connector position and drawing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat the signals tell you.\u003c\/strong\u003e A\/B provide 2,048 cycles per mechanical revolution. R is the reference-mark channel. C\/D give one sine\/cosine cycle per mechanical revolution and carry the commutation position information. A usable A\/B trace can coexist with a C\/D fault or incorrect commutation alignment. For qualified waveform testing, use the approved fixture, receiver termination and a differential measurement across each +\/− pair. A handheld meter reading on one leg cannot validate amplitude, quadrature or alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Produktinformationen\/PI_ECN1313_ECN1325_ERN1387_Elevator_Drive_Control_ID1085677_en.pdf#page=5\"\u003eHEIDENHAIN electrical reference (PDF, p. 5)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"motor-cables\" style=\"scroll-margin-top: 6rem;\"\u003eStandard ERN 1387 cables inside the motor\u003c\/h3\u003e\n\u003cp\u003eHEIDENHAIN lists these AGK output leads for the \u003cstrong\u003eERN 1387 with a 14-pin FCI PCB connection\u003c\/strong\u003e. Match the motor flange, pin map, cable length and temperature-sensor wiring to your motor’s drawing before ordering.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\" role=\"region\" aria-label=\"ERN 1387 internal motor cable part numbers\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eHEIDENHAIN internal motor leads\u003cbr\u003e\u003cbr\u003e\n\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eHEIDENHAIN cable ID\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eLength\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEnds and use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e332199-01\u003c\/th\u003e\n\u003ctd\u003e0.3 m\u003c\/td\u003e\n\u003ctd\u003e14-pin PCB plug to 17-pin M23 right-angle flange socket with male contacts. Includes two temperature-sensor wires.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e332200-01\u003c\/th\u003e\n\u003ctd\u003e0.3 m\u003c\/td\u003e\n\u003ctd\u003e14-pin PCB plug to an unstripped cable end for the motor maker’s termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e332200-04\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003ctd\u003e14-pin PCB plug to an unstripped cable end for the motor maker’s termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.heidenhain.us\/wp-content\/uploads\/2022\/09\/PR_Cables_and_Connectors_ID1206103_en.pdf\"\u003eHEIDENHAIN Cables and Connectors 1206103 (PDF). Search for 332199-01 in the cable list.\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eHeidenhain ERN 1387 Troubleshooting DoitYourself : What you can check on the machine\u003c\/h2\u003e\n\u003cp\u003eRecord the exact drive alarm, when it occurs and any recent work on the encoder, motor, cable or drive. Start with the connector and cable. A fault that changes when the machine moves may be in the cable or its termination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore touching the assembly.\u003c\/strong\u003e Authorized technicians should follow the machine and site lockout procedure. Isolate all energy sources, secure loads against motion, handle stored energy including drive capacitors, and verify isolation and de-energization before disconnecting anything. Elevator and suspended-load work requires the applicable site and OEM procedures. \u003ca href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.147\"\u003eHazardous-energy control reference\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"connector-check\"\u003eConnector condition and seating\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eWith power isolated, inspect both mating faces in good light. Look for bent or recessed pins, cracked inserts, corrosion, moisture and debris. A metal chip or stray shield strand can bridge adjacent contacts. Use the connector maker’s approved cleaning method. Replace damaged contacts or housings before mating them.\u003c\/li\u003e\n\u003cli\u003eCheck the cable for crushed sections, abrasion or a loose backshell or strain relief. Align the key, seat the feedback plug squarely on the motor socket, then engage the latch or coupling collar as specified by the motor maker. A tight collar alone does not prove the plug is seated. Confirm the motor socket is secure and the cable’s weight is supported by the strain relief.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 id=\"cable-check\"\u003eElectrical check with power off · Cable continuity and shorts\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect the passive feedback cable at \u003cstrong\u003eboth ends\u003c\/strong\u003e and separate it from any inline electronics or sensors. Use the drawing for that exact harness. Set a multimeter to resistance or continuity, touch the probes together to establish lead resistance, and use adapters that fit the contacts.\u003c\/li\u003e\n\u003cli\u003eCheck each intended path end to end. A good path has low, stable resistance consistent with the cable length and specification. An open indication (usually \u003cstrong\u003eOL\u003c\/strong\u003e) or a reading that jumps when you gently flex the isolated cable suggests a broken conductor or contact problem.\u003c\/li\u003e\n\u003cli\u003eCheck for shorts between adjacent pins and other conductors that the drawing shows as isolated. Check U\u003csub\u003eP\u003c\/sub\u003e to 0 V and each signal lead to 0 V. Also check each signal lead to the shield and to the metal shell where accessible. An isolated pair normally reads open. A stable low resistance on a pair that should be isolated points to a bridge in the cable or plug. A documented shield-to-shell bond can read low by design. 0 V is the encoder supply return. The shield and shell serve a separate purpose.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eKeep resistance and insulation testers off connected feedback electronics. The encoder ties its sense leads to the corresponding supply rails internally. The isolated-cable check avoids mistaking those internal paths for a cable short. A cable can pass these checks and still have noise or signal-quality problems. \u003ca href=\"https:\/\/www.fluke.com\/en-us\/learn\/blog\/digital-multimeters\/how-to-test-for-continuity\"\u003eFluke continuity guide\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"mounting-check\"\u003eMechanical check · Center screw and stator coupling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCenter screw.\u003c\/strong\u003e With the motor isolated and secured, inspect the fastener and spacer stack where the OEM procedure allows access. Look for a backed-out screw, shifted witness marks or evidence the shaft has moved on the taper. The center screw retains the encoder rotor on the motor shaft. Tightening by feel cannot establish that the taper is seated or that the encoder is still aligned.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStator coupling.\u003c\/strong\u003e The encoder body should be held rigidly against rotation relative to the motor housing. On \u003cstrong\u003e749144-01\u003c\/strong\u003e and \u003cstrong\u003e749144-05\u003c\/strong\u003e, check that the Type 06 expanding ring is seated in its mating bore and that there is no visible shift or looseness. For \u003cstrong\u003e749147-02\u003c\/strong\u003e, inspect the actual OEM stator attachment. HEIDENHAIN supplies that ID without a coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the shaft or body has shifted, record what moved and keep the motor out of service until the fit, fasteners and commutation alignment have been verified against the applicable OEM instructions. \u003ca href=\"#mounting\"\u003eMounting drawings by ID\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"supply-check\"\u003eElectrical check with feedback powered · 5 V supply under load\u003c\/h3\u003e\n\u003cp\u003eThis check is for a qualified technician with protected low-voltage test points or an OEM-approved breakout harness. Fit the breakout while isolated and keep the encoder connected so the reading is under load. Use the approved test state that powers feedback while preventing motor motion and keeping loads secured. Leave exposed live cabinet parts and closely spaced plug contacts to specialist testing. \u003ca href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.333\"\u003eElectrical work practices\u003c\/a\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eSet the meter to \u003cstrong\u003eDC volts\u003c\/strong\u003e. Put the black lead in \u003cstrong\u003eCOM\u003c\/strong\u003e and the red lead in the \u003cstrong\u003eV\/Ω\u003c\/strong\u003e socket. A current jack can short the supply during a voltage measurement.\u003c\/li\u003e\n\u003cli\u003eMeasure at the encoder end with black on \u003cstrong\u003e0 V\u003c\/strong\u003e and red on \u003cstrong\u003eU\u003csub\u003eP\u003c\/sub\u003e\u003c\/strong\u003e. Through the breakout for the documented 14-pin layout, use \u003cstrong\u003eblack on 5b, red on 1b\u003c\/strong\u003e. For HEIDENHAIN’s documented 17-pin M23 arrangement, use \u003cstrong\u003eblack on 10, red on 7\u003c\/strong\u003e. Use the exact motor drawing for any OEM external connector and confirm its viewing side. Use the supply return as the meter reference.\u003c\/li\u003e\n\u003cli\u003eExpect \u003cstrong\u003e4.75–5.25 V DC at the encoder\u003c\/strong\u003e for the three IDs above. If the reading is low at the encoder, compare with the drive’s documented supply test point under the same conditions. A healthy source with a low reading at the encoder points toward a voltage drop in the supply or return path, including a poor contact. A low reading at both ends calls for checking the drive supply, protection state and connected load. If the reading is high, stop and verify the supply setting and pin assignment. A good steady reading confirms the supply only at the time of the test.\u003c\/li\u003e\n\u003cli\u003eReturn the equipment to its isolated state before removing the breakout or disturbing a plug.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.fluke.com\/en-ie\/learn\/blog\/digital-multimeters\/how-to-measure-dc-voltage-with-a-digital-multimeter\"\u003eFluke DC voltage guide\u003c\/a\u003e · \u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Produktinformationen\/PI_ECN1313_ECN1325_ERN1387_Elevator_Drive_Control_ID1085677_en.pdf#page=5\"\u003eHEIDENHAIN connector reference (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eWhat you observe\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to check next\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault changes with cable position\u003c\/th\u003e\n\u003ctd\u003e\n\u003ca href=\"#connector-check\"\u003eInspect strain relief and contacts\u003c\/a\u003e, then \u003ca href=\"#cable-check\"\u003eflex-test the disconnected cable\u003c\/a\u003e. If the symptom stays with a known-good cable, inspect the motor-side connector and internal pigtail.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDropout mainly during motion or high load\u003c\/th\u003e\n\u003ctd\u003eCheck feedback-cable routing, documented shield bonds, connector condition and \u003ca href=\"#supply-check\"\u003esupply under load\u003c\/a\u003e. Ask a technician to capture waveforms during the fault under an approved test setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault began after replacement or mechanical work\u003c\/th\u003e\n\u003ctd\u003eCompare the complete IDs, \u003ca href=\"#mounting-check\"\u003etaper seating, coupling and spacer stack\u003c\/a\u003e, and connector map. Verify C\/D and OEM commutation alignment before returning the axis to service.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo position feedback with a known-good cable\u003c\/th\u003e\n\u003ctd\u003eA controlled bench test can separate an encoder fault from machine wiring or a drive input problem. If the encoder passes on the bench, check the machine-side supply, receiver and drive configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf these checks pass and the fault remains, a differential waveform or bench test can check signal quality and commutation. Capture the original alignment before disturbing the assembly when the OEM procedure calls for it. \u003ca href=\"#mitchell-tests\"\u003eSee the specialist test options\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eWhere Heidenhain ERN 1387 is USED on Servo Motor applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens.\u003c\/strong\u003e Mitchell documents ERN 1387-style sine\/cosine commutation feedback on some 1FT6, 1FK6, 1FT7 and 1FK7 motors. Read the complete motor order code and feedback option before using an external connector drawing. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/42346415920027-Siemens-Motors\"\u003eMitchell’s Siemens motor guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoog.\u003c\/strong\u003e Mitchell identifies ERN 1387 as one possible HEIDENHAIN incremental option alongside ERN 1185. Match the actual label and motor code. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/48944747309339-MOOG-Motors\"\u003eMitchell’s Moog motor guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHEIDENHAIN QSY and elevator servo applications.\u003c\/strong\u003e Manufacturer literature lists QSY 96, 130 and 260 cable applications with ERN 1387 and documents its use in elevator servo-drive control. Match the assembly and drawing to the actual motor. \u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_HEIDENHAIN-Motors_OEM_ID208893_en.pdf\"\u003eQSY motor brochure (PDF)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eEncoder angle adjustment · Siemens servo motors\u003c\/h2\u003e\n\u003cp\u003eCommutation alignment ties the encoder’s position reference to the motor rotor’s electrical phase. Use the complete motor order code, encoder version and OEM instructions to select the reference. Mitchell documents this feedback on some Siemens 1FT6, 1FK6, 1FT7 and 1FK7 builds.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\" role=\"region\" aria-label=\"Siemens bench alignment reference angles\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMitchell TI-5000JX Siemens bench targets · Normal Commutation mode\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eDocumented static rotor lockup\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical angle on tester\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e+U \/ −V\u003c\/th\u003e\n\u003ctd\u003e150° electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e+U \/ −W\u003c\/th\u003e\n\u003ctd\u003e210° electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese are tester readings at two specific rotor lockups on the documented Siemens setup. Confirm phase identification, feedback direction and the motor pole count. Use \u003cstrong\u003eNormal Commutation\u003c\/strong\u003e for the bench alignment reference and \u003cstrong\u003eSin\/Cos Commutation\u003c\/strong\u003e to inspect C\/D signals. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4409340233371-Siemens-motors-with-Heidenhain-ERN1387-or-Hengstler-S21-RS53-encoders\"\u003eMitchell’s Siemens ERN 1387 procedure\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/sections\/26370850277403-TI-5000JX-Training-Manual\"\u003eTI-5000JX training manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens OEM verification.\u003c\/strong\u003e In §4.6.1, Siemens specifies a dynamic check for the listed 1FT6, 1FK6 and 1FK7 configurations with ERN 1387.001, .003 or .020. The encoder reference mark coincides with the rising zero crossing of the phase-U back EMF measured to neutral in Siemens’ setup. Use the motor-specific procedure for other builds, including 1PH, Moog and elevator motors. \u003ca href=\"https:\/\/cache.industry.siemens.com\/dl\/files\/645\/57245645\/att_23246\/v1\/Geber_ERN1387_BE_0105_en_de.pdf\"\u003eSiemens assembly and adjustment instructions 610.41 304.02 (PDF, printed p. 20)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQualified bench work.\u003c\/strong\u003e Secure the motor and load, isolate the machine drive and follow the approved fixture and commissioning procedure. A back-driven permanent-magnet motor generates voltage. Verify alignment on the assembled motor before returning the axis to service.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings and manuals relevant to Heidenhain ERN 1387\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Produktinformationen\/PI_ECN1313_ECN1325_ERN1387_Elevator_Drive_Control_ID1085677_en.pdf\"\u003eERN 1387 product information (PDF)\u003c\/a\u003e — application-specific specifications and drawings on pp. 2–3, connector views and pin table on p. 5.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/ERN_1387_65B07B_37D_1033640-91.pdf\"\u003e65B\/06 mounting instructions (PDF)\u003c\/a\u003e — check the configuration codes on the cover before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/ECN1313_ERN1326_ERN1387_06%2065B_BA_1460657_Ver00_09_mu.pdf\"\u003eHEIDENHAIN 06\/65B operating instructions (PDF)\u003c\/a\u003e — applicability and instructions for the encoder.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/sections\/26370850277403-TI-5000JX-Training-Manual\"\u003eMitchell TI-5000JX Training Manual\u003c\/a\u003e — specialist feedback testing reference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51114511499429,"sku":"STP45","price":98.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/HEIDENHAIN_ERN_1387_Encoder_Service_Technical_Guide_Book_UAE_Location_Factory_Visit-_ServiceAlign.jpg?v=1794045612","url":"https:\/\/www.sparefaber.com\/ar\/products\/heidenhain-ern-1387","provider":"SpareFaber","version":"1.0","type":"link"}