{"product_id":"hengstler-ad36-ssi-feedback-technical-guide","title":"Hengstler AD36 SSI | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eHengstler AD36 SSI — SSI absolute, order-specific. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eHengstler AD36 SSI — Standalone device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eAD36 SSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain designation\u003c\/th\u003e\n\u003ctd\u003eAD36 SSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented motor example\u003c\/th\u003e\n\u003ctd\u003eNo complete fitted motor order has been verified; retain every nameplate suffix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eSSI absolute, order-specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eMatch the fitted connector and OEM drawing; exact lead assignment remains open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration distinction\u003c\/th\u003e\n\u003ctd\u003eGTY2 covers AD36 BiSS-C; the SSI branch has a different electrical setup and order code.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eTI-5000JX feedback evaluation is conditional on the exact fitted option and verified fixture. Read the SSI interface code, singleturn\/multiturn resolution, shaft option and connector orientation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eMatch the fitted connector and OEM drawing; exact lead assignment remains open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eVerify exact supply, profile, connector and installed software. Named model evidence does not establish a complete fitted setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eMotor-run setup conditional on exact motor, feedback, poles, wiring, alignment, lead\/module and installed TI-3000JX profile.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe documented test reference is Hengstler Encoders — AD36 SSI. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eCurrent order availability and a verified successor for the exact fitted item remain to confirm. Technical documentation does not establish stock or a drop-in replacement. Match mechanical fit, interface, connector, memory and motor\/drive requirements before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface \/ feedback option\u003c\/th\u003e\n\u003ctd\u003eSSI absolute, order-specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder-dependent fields\u003c\/th\u003e\n\u003ctd\u003eSSI Gray\/binary, position word length, turn field, supply and optional analogue signals must be decoded from the full order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector drawing\u003c\/th\u003e\n\u003ctd\u003eUse the correct 12-pole PCB contact view and axial\/radial orientation. Do not borrow AD58 wire colours.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact dimensions and fastening\u003c\/th\u003e\n\u003ctd\u003eUse the matching manufacturer outline, shaft drawing and revision. No universal shaft torque, air gap or fastener setting is assigned.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eSSI uses separate clock and data paths. Decode the exact Gray\/binary format, position bits, turn field and timing from the order documentation. Where TTL or sine\/cosine tracks are present, inspect them independently from the serial position. A plausible number from guessed word framing is not proof of a healthy matched installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003ePhotograph the incoming reference, locating seat, shaft restraint, fasteners and cable exit before removal. Inspect accessible looseness, contamination, rubbing and bearing condition after isolation. Use the fitted outline for shaft engagement, retention and rear clearance. Preserve the incoming alignment and do not force an encoder or apply a torque from a similar-looking assembly.\u003c\/p\u003e\n\u003cp\u003eAD36 is a family with SSI and BiSS variants. The linked technical datasheet identifies SSI Gray and binary options and separate optional sine\/cosine outputs. Match the complete order rather than assigning the headline 22-bit capability to every SSI unit. Hub-shaft and through-hollow-shaft drawings, supply options and 12-pole connector orientation must be read together.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eTreat the sensor plug, internal motor loom, bulkhead, external machine cable and receiver as separate interfaces. Confirm contact numbering, keying, gender and the drawing view before tracing conductors. Identify supply\/return, signal pairs, temperature, shield and any separate brake wiring individually. Obtain the contact diagram for the actual connector before wiring an adapter. The linked datasheet supplies connector drawings; preserve the selected SSI option and drawing revision. Do not mix AD36 and AD58 contact numbering or wire-colour columns.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: Match the fitted connector and OEM drawing; exact lead assignment remains open. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eAn exact internal OEM loom part number has not been established for the fitted unit. Record both loom ends and obtain the motor assembly drawing. External cable choice depends on receiver, length, shielding and fixed\/flexing installation. A Mitchell test lead identifies a bench connection, not an OEM machine-cable replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentify the configuration first\u003c\/th\u003e\n\u003ctd\u003eAD36 is a family with SSI and BiSS variants. The linked technical datasheet identifies SSI Gray and binary options and separate optional sine\/cosine outputs. Match the complete order rather than assigning the headline 22-bit capability to every SSI unit. Hub-shaft and through-hollow-shaft drawings, supply options and 12-pole connector orientation must be read together.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault while the cable moves\u003c\/th\u003e\n\u003ctd\u003eAfter isolation and disconnection at both ends, inspect flex points, repairs, pin engagement and contamination. Compare continuity and unintended shorts against the exact drawing, allowing for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo signal or communication\u003c\/th\u003e\n\u003ctd\u003eVerify full order, interface, fixture and supply range. A qualified technician can compare source and load voltages with the approved breakout and OEM procedure; connector shape alone does not specify supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition reads but the drive still rejects feedback\u003c\/th\u003e\n\u003ctd\u003eCheck the independent signal paths, direction, motor identity and any supported reference\/turn status. Record the original alarm before changing settings. A data reset is not a substitute for identifying the fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming shaft datum, direction, motor phase convention and recoverable data before disturbing feedback. Use the exact OEM procedure and supported equipment for alignment or replacement. Matching electrical signals alone does not establish the correct motor pairing or machine origin.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eAD36 SSI fitted application to verify. GTY2 covers AD36 BiSS-C; the SSI branch has a different electrical setup and order code.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/45936997944347-Hengstler-Encoders\" target=\"_blank\" rel=\"noopener\"\u003eHengstler Encoders\u003c\/a\u003e — AD36 SSI\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=5c0120c6-4e09-427c-85c3-c999c3fefe9b\" target=\"_blank\" rel=\"noopener\"\u003eHengstler AD36 BiSS\/SSI datasheet 081123 EN\u003c\/a\u003e — Exact family, feedback option, connection drawing and revision only\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.hengstler.com\/products\/rotary-encoders\/absolute-encoders\/ad36\" target=\"_blank\" rel=\"noopener\"\u003eHengstler ACURO AD36 family\u003c\/a\u003e — SSI\/BiSS family; match exact interface, shaft, resolution and connector code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eObtain the complete fitted order, internal loom drawing, connector contact view and approved fixture before fitted-unit work. The linked family document does not establish interchangeability for every order.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a AD36 SSI enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eMotor-run setup conditional on exact motor, feedback, poles, wiring, alignment, lead\/module and installed TI-3000JX profile. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51146692296869,"sku":"TCG581","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/hengstler-ad36-ssi-service-guide.jpg?v=1794342275","url":"https:\/\/www.sparefaber.com\/ar\/products\/hengstler-ad36-ssi-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}