{"product_id":"jtekt-koyo-trd-sh1024vd","title":"JTEKT Koyo TRD-SH1024VD Differential Hollow-Shaft Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for TRD-SH1024VD installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"JTEKT Koyo TRD-SH1024VD Differential Hollow-Shaft Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eCheck count per turn, differential levels, A\/B phase and index in a suitable fixture and under the documented load. Compare signals at the controller to find a wiring or input problem. Exact Mitchell adapter support remains unverified.\u003c\/p\u003e\n\u003ch2\u003eJTEKT Koyo TRD-SH1024VD Differential Hollow-Shaft Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eTRD-SH1024VD\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTRD-SH1024VD\u003c\/th\u003e\n\u003ctd\u003eØ38 mm body, 8 mm hollow shaft, 2 m integral cable.\u003c\/td\u003e\n\u003ctd\u003e1,024 pulses\/rev, 5 V differential line driver, A\/B\/Z.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTRD-S1024VD\u003c\/th\u003e\n\u003ctd\u003eSeparate solid-shaft model in the TRDV declaration.\u003c\/td\u003e\n\u003ctd\u003e1,024 P\/R VD line-driver variant. Verify shaft fit and installation drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTRD-SH … AD or BD\u003c\/th\u003e\n\u003ctd\u003eRelated hollow-shaft versions.\u003c\/td\u003e\n\u003ctd\u003eDifferent open-drain output and supply requirements. Use the AD or BD column.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eAutomationDirect lists the exact TRD-SH1024VD in its Retired Products catalogue. Confirm current JTEKT production or a supported successor with the manufacturer.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for TRD-SH1024VD\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for TRD-SH1024VD\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit \/ lead\u003c\/th\u003e\n\u003ctd\u003e38 mm body, 8 mm hollow bore, 2 m integral lead, IP40 in the exact cutsheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e5 V nominal. VD diagram gives 4.75–5.25 V DC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003eDifferential line-driver A\/B\/Z. 1,024 pulses per revolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical limits\u003c\/th\u003e\n\u003ctd\u003eFamily installation sheet states up to 6,000 rpm and uses the lower frequency-derived or mechanical limit. Exact cutsheet lists 20 N radial and 10 N axial load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/cdn.automationdirect.com\/static\/manuals\/encoderinserts\/trd-s_series.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the TRD-SH hollow-shaft diagram and mating shaft requirements. Check the 8 mm shaft fit, retaining arrangement, runout and bracket alignment. Keep the lead clear of the moving shaft. Follow the installation diagram for seating and fastening.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe VD differential driver sends A\/B quadrature and Z index. The receiving counter determines direction from the phase relation and can count one, two or four edges per cycle depending on its configuration. Set the receiver for the documented 5 V line-driver circuit.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the \u003cstrong\u003eVD line-driver\u003c\/strong\u003e connection drawing on the installation sheet. The following colours refer to the original encoder lead. Map them independently through any OEM plug.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"TRD-SH1024VD integral lead\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eTRD-SH1024VD integral lead\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWire\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e+5 V \/ 0 V\u003c\/th\u003e\n\u003ctd\u003eBrown \/ blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA+ \/ A−\u003c\/th\u003e\n\u003ctd\u003eBlack \/ purple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eB+ \/ B−\u003c\/th\u003e\n\u003ctd\u003eWhite \/ grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ+ \/ Z−\u003c\/th\u003e\n\u003ctd\u003eOrange \/ yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScreen\u003c\/th\u003e\n\u003ctd\u003eFollow the machine scheme. At 1,024 P\/R the sheet shows no internal screen-to-housing bond.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe exact cut sheet describes the integral 2 m lead. For an extension, use the suitable differential pairs, screen and supply conductors per the receiver and machine drawings. Keep away from motor and power cabling. Obtain the exact remote connector from the machine loom.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMissing all signals\u003c\/th\u003e\n\u003ctd\u003eVerify 4.75–5.25 V across brown\/blue under approved conditions. Confirm the driven shaft and receiver mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCount runs in the wrong direction\u003c\/th\u003e\n\u003ctd\u003eCheck A\/B mapping and polarity from both ends, then confirm the PLC direction setting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise or losses when a drive switches\u003c\/th\u003e\n\u003ctd\u003eInspect routing, screen, pair integrity and the receiver differential termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse on compatible machine counters and drive inputs with an 8 mm mating shaft and a 5 V differential receiver. The related AD and BD output variants require their own circuit and supply check.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eInstall the encoder in the documented mechanical orientation, verify count direction and re-establish machine zero via the approved homing procedure. The Z channel aids reference recovery. Use the OEM motor instructions if the machine also requires motor commutation setup.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.automationdirect.com\/static\/manuals\/encoderinserts\/trd-s_series.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.automationdirect.com\/adc\/shopping\/catalog\/retired_products\/sensors_-z-_encoders\/trd-sh1024vd\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.automationdirect.com\/static\/specs\/cutsheet\/TRD-SH1024VD_cutsheet.pdf\"\u003eTRD-SH1024VD exact cut sheet\u003c\/a\u003e. Confirms ID, body, bore, output and lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.automationdirect.com\/adc\/shopping\/catalog\/retired_products\/sensors_-z-_encoders\/trd-sh1024vd\"\u003eDistributor retirement record\u003c\/a\u003e. Use to distinguish distributor orderability from manufacturer lifecycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.automationdirect.com\/docs\/ce-encoder-trdv.pdf\"\u003eTRDV declaration and model list\u003c\/a\u003e. Lists the separate TRD-S1024VD solid-shaft model.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118432878757,"sku":"TCG69","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/JTEKTKoyoTRD-SH1024VDDifferentialHollow-ShaftEncoder.jpg?v=1794131754","url":"https:\/\/www.sparefaber.com\/ar\/products\/jtekt-koyo-trd-sh1024vd","provider":"SpareFaber","version":"1.0","type":"link"}