{"product_id":"kawasaki-he-02-e03007758","title":"Kawasaki HE-02 Sanyo Denki E03007758 Robot Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for HE-02 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Kawasaki HE-02 Sanyo Denki E03007758 Robot Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eWe can compare the HE-02 serial position and quadrature path, then check the robot's motor harness and reference history. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell documents HE-02 serial and separate quadrature tests on TI-5000JX. Its TI-3000JX guide also documents HE-02 run selections by motor pole count. Match the actual motor phases and pole count, 17-pin fixture and selection before any controlled run.\u003c\/p\u003e\n\u003ch2\u003eKawasaki HE-02 Sanyo Denki E03007758 Robot Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eE03007758\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE03007758 \/ HE-02\u003c\/th\u003e\n\u003ctd\u003eMitchell cross-references the Sanyo Denki and Kawasaki designations. Confirm the full encoder label and motor nameplate.\u003c\/td\u003e\n\u003ctd\u003eSerial section plus quadrature pulse section. 8,192 counts per turn in the documented setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eH20\/M21\u003c\/th\u003e\n\u003ctd\u003eOther Kawasaki feedback used on different motors and harnesses.\u003c\/td\u003e\n\u003ctd\u003eMitchell assigns separate direct and motor cables. Match the complete label even where counts per turn agree.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eMitchell documents the installed family. Confirm Kawasaki or Sanyo Denki replacement availability from the actual robot axis and motor serial.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for E03007758\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for E03007758\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback\u003c\/th\u003e\n\u003ctd\u003eKawasaki serial and quadrature per Mitchell HE-02 reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCounts per mechanical turn\u003c\/th\u003e\n\u003ctd\u003e8,192 for HE-02 \/ E03007758 in Mitchell's documented test setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented motor-side lead\u003c\/th\u003e\n\u003ctd\u003eTI-5026 for the 17-pin circular MS variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOther test lead\u003c\/th\u003e\n\u003ctd\u003eTI-5023 is listed with conflicting D-sub sizes in the support article and cable index. Confirm the current cable sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor pole options in run guide\u003c\/th\u003e\n\u003ctd\u003eMitchell lists separate P4, P6 and P8 HE-02 profiles. Verify the specific motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eBefore removing the encoder, record the full robot, axis and servo motor order, the as-found orientation and any reference marks. With the axis secured and isolated, inspect the coupling, rotor retention and encoder housing mounting. Get the motor assembly drawing for fit dimensions and fastening. Preserve the robot reference data through the approved service procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe HE-02 supplies a serial position path and a separate quadrature path. A bench test can compare them over the same shaft movement. A good serial read can coexist with a damaged pulse path or harness conductor. If the readings agree on the bench, compare motor-side and controller-side signals and check the axis reference.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eObtain the exact motor-side drawing and TI-5026 connector sheet before powering the device. Use the plug view and cavity numbers on the actual connector. Separate the serial pair, incremental conductors, supply and shield in the harness checks. Confirm the supply at the approved reference points for the fitted HE-02 build.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eTI-5026 is documented for the 17-pin circular MS connection. Mitchell also lists TI-5023, but its support and index descriptions differ on the D-sub size. Use the latest drawing and actual plug to resolve that conflict. Identify the installed internal lead and the robot axis cable by the full motor and robot serial.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial works, count or speed feedback drops\u003c\/th\u003e\n\u003ctd\u003eCompare the quadrature pair at both ends with the correct receiver and check the disconnected harness.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoth paths disappear when the axis flexes\u003c\/th\u003e\n\u003ctd\u003eCheck supply, plug latch, shell connection and strain points in the cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncorrect axis reference after replacing feedback\u003c\/th\u003e\n\u003ctd\u003eVerify mechanical retention and the OEM reference or mastering procedure before production movement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition runs in the wrong direction or shows the wrong count\u003c\/th\u003e\n\u003ctd\u003eConfirm the precise encoder selection and drive or tester configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMitchell identifies HE-02 on applicable Kawasaki robot motors and cross-references the Sanyo Denki E03007758. The exact axis and motor suffix must be verified from their labels. The H20\/M21 protocol and cable leads are listed separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eKeep the robot's axis reference, rotor commutation and mechanical coupling relationship separate. Record the original assembly and controller state before encoder removal. After any approved replacement, verify the OEM commissioning and reference procedure for that robot, axis and motor.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26662706352411-Kawasaki-Motors-and-Serial-Encoders\"\u003eMitchell Kawasaki serial encoder guide\u003c\/a\u003e. HE-02 identity, count and serial versus pulse checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26663411053851-Kawasaki-Motors\"\u003eMitchell Kawasaki run guide\u003c\/a\u003e. HE-02 motor run options by pole count.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell manufacturer cable index\u003c\/a\u003e. TI-5026 17-pin MS and TI-5023 catalogue entry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese references describe the application and test route. The OEM encoder datasheet is still needed.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51124701331621,"sku":"TCG123","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/kawasaki-he-02-e03007758-service-guide.jpg?v=1794210224","url":"https:\/\/www.sparefaber.com\/ar\/products\/kawasaki-he-02-e03007758","provider":"SpareFaber","version":"1.0","type":"link"}