{"product_id":"keba-lti-lst-097-4-g6-1m-srm50-feedback-technical-guide","title":"KEBA \/ LTi LST-097-4 \/ G6.1M SRM50 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eKEBA \/ LTi LST-097-4 \/ G6.1M\u003c\/strong\u003e uses the documented SRM50 multiturn classic HIPERFACE option. This guide helps identify the fitted feedback, distinguish an encoder fault from a cable or setup issue, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting scope\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted configuration\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ motor base\u003c\/td\u003e\n\u003ctd\u003eKEBA \/ LTi LST-097-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelected OEM feedback option\u003c\/td\u003e\n\u003ctd\u003eG6.1M — SRM50, multiturn classic HIPERFACE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentifier scope\u003c\/td\u003e\n\u003ctd\u003eMotor base plus feedback selection; not a complete motor order. Confirm every fitted suffix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraked representative\u003c\/td\u003e\n\u003ctd\u003eB — 24 V holding-brake option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService reference\u003c\/td\u003e\n\u003ctd\u003eTCG1514 — SpareFaber reference, not an OEM part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eConfirm the complete motor order, encoder suffix\/serial, drive model and connector revision. The catalogue connects this base and option to the named feedback family; an exact Mitchell entry for this motor was not found in the reviewed material. That does not prevent scoped testing of the positively identified feedback.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX: identified SRS50 \/ SRM50 classic HIPERFACE feedback. Evaluate serial position and analogue signals; retain incoming alignment\/memory.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting connection:\u003c\/strong\u003e TI-5069 direct to verified SRS\/SRM 8-pin encoder plug; TI-5104 after label\/supply check. Motor-bulkhead adapter is not established by this proposal.\u003c\/p\u003e\n\u003cp\u003eMatch the actual encoder selection and lead in the installed Athena software. Check identity\/status and serial position, then evaluate the analogue path separately. A clean position count alone does not prove correct analogue amplitude or installed commutation alignment. Record the equipment, cable, software version and fitted encoder label with the result; no minimum firmware version is asserted for this exact assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor-run scope:\u003c\/strong\u003e Unestablished for this exact motor. Confirm motor parameters, fixture, phase order, brake, alignment and installed TI-3000JX profile before run testing.\u003c\/p\u003e\n\u003cp\u003eThe MOOG reference is used only because it documents the identified encoder families and their direct connectors. It does not authorize a MOOG motor profile, machine cable or alignment value for this application.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSignals and specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented value \/ boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor base\u003c\/td\u003e\n\u003ctd\u003eKEBA \/ LTi LST-097-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelected feedback\u003c\/td\u003e\n\u003ctd\u003eG6.1M — SRM50, multiturn classic HIPERFACE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eSerial RS-485 absolute position plus analogue sine\/cosine paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial position per revolution\u003c\/td\u003e\n\u003ctd\u003e32,768 positions (15 bits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue periods per revolution\u003c\/td\u003e\n\u003ctd\u003e1,024 sine\/cosine periods; not drive-scaled counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-revolution information\u003c\/td\u003e\n\u003ctd\u003e4,096 revolutions (12-bit turn range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback supply\u003c\/td\u003e\n\u003ctd\u003e7–12 V DC in the scoped OEM table; verify the fitted encoder label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake selection\u003c\/td\u003e\n\u003ctd\u003eB — 24 V DC holding-brake option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue stall torque\u003c\/td\u003e\n\u003ctd\u003e7.5 Nm at the catalogue conditions; not continuous torque at every speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG6.1x motor length with brake\u003c\/td\u003e\n\u003ctd\u003e274 mm, catalogue p.87; match shaft and connection options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding brake\u003c\/td\u003e\n\u003ctd\u003e24 V DC option B; 9 Nm catalogue braking torque, ±10%; p.87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power \/ speed order\u003c\/td\u003e\n\u003ctd\u003eNot assigned by this guide; read the complete motor nameplate and winding suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eAnalogue periods, serial positions, multi-revolution range and drive-scaled counts are different quantities. A catalogue period count is not an assumed controller resolution. Feedback supply, motor DC-link\/drive supply and brake supply are separate circuits.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eLST-097-4\u003c\/strong\u003e has 7.5 Nm catalogue stall torque. Its G6.1x motor length with the B brake option is 274 mm in the p.87 dimensional table. This is a catalogue motor-housing dimension, not an encoder body length or shaft diameter.\u003c\/p\u003e\n\u003cp\u003eUse the LST-097 drawing on p.87 to compare the fitted shaft, flange, pilot and connection selection. A common frame or feedback family does not establish interchangeability between different motor lengths, S\/K connection variants or special X builds. Confirm the complete speed\/DC-link\/winding fields rather than creating separate winding-only feedback guides.\u003c\/p\u003e\n\u003cp\u003eBefore loosening retention, preserve the incoming shaft reference and record the encoder locating seat, coupling, anti-rotation support and cable route. Exact internal fastener torques, air gap and fitted loom number remain specific to the complete assembly; obtain the relevant assembly drawing before replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eKEBA catalogue p.115 distinguishes the \u003cstrong\u003e17-pin M23 optical-encoder socket\u003c\/strong\u003e from the 12-pin resolver socket. Use the G6.x column below and the original connector drawing to establish view and keying.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eOEM motor feedback contact\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSignal \/ scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003ctd\u003eA+ \/ A−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 \/ 4\u003c\/td\u003e\n\u003ctd\u003eB+ \/ B−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eGND \/ 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eVCC 7–12 V \/ 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 \/ 11\u003c\/td\u003e\n\u003ctd\u003eDATA+ \/ DATA−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8, 12, 13, 16, 17\u003c\/td\u003e\n\u003ctd\u003eNot used for G6.x in this table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5, 6, 14, 15\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eIn the adjacent SSI\/EnDat column, pin 8 is +5 V and separate clock\/sense contacts are present. Those assignments do not belong to G6.1S\/G6.1M. Do not bridge pins 8 and 9 or substitute the neighbouring table. Match the complete S\/K connection option and motor power\/brake drawing independently.\u003c\/p\u003e\n\u003cp\u003eUse the original drawing to confirm contact view, keying and revision before wiring. No pin assignment here is a terminal-block map for the Mitchell tester.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eInternal, machine and test cables\u003c\/h2\u003e\n\u003cp\u003eTI-5069 direct to verified SRS\/SRM 8-pin encoder plug; TI-5104 after label\/supply check. Motor-bulkhead adapter is not established by this proposal.\u003c\/p\u003e\n\u003cp\u003eThe direct-to-encoder lead is an internal bench connection. The motor bulkhead connector, machine extension and drive-end connector form separate interfaces. No verified internal loom or complete machine-cable part number is established for this exact full order. Record both-end connector photos, cable markings, routing and required length before selecting a replacement harness.\u003c\/p\u003e\n\u003cp\u003eCheck the manufacturer drawing and current Mitchell lead sheet together before adapting a connection. A compatible communication protocol does not make a physical plug or pinout interchangeable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cp\u003eBefore physical checks, secure the driven load, isolate and lock out relevant energy sources, observe the specified discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short checks and account for intentional shield bonds. Powered measurement, rotation, brake release and alignment require the applicable specialist procedure.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eUseful next check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo serial position or incorrect encoder identity\u003c\/td\u003e\n\u003ctd\u003eVerify the fitted model and software choice, approved supply and serial pair, then inspect connector seating and cable condition. Separate cable and encoder tests before replacing the sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial position reads but analogue path is weak or noisy\u003c\/td\u003e\n\u003ctd\u003eConfirm the correct sine\/cosine pairs and source amplitude using the approved signal test. Inspect shielding, contamination and cable damage; an incrementing serial count does not clear the analogue channels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition or direction changes after refitting\u003c\/td\u003e\n\u003ctd\u003eCompare full feedback option, drive scaling\/direction, preserved offset and mechanical reference. Do not copy an offset from a similar motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn information is unexpected after service\u003c\/td\u003e\n\u003ctd\u003eCompare the saved incoming turn value, machine reference and actual shaft history under the approved test procedure. Preserve motor data before any reset or write; do not assume a turn discrepancy is a battery fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault follows cable movement\u003c\/td\u003e\n\u003ctd\u003eWith the installation isolated, inspect strain relief, pin retention, moisture and both-end cable continuity against the actual wiring drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor will not turn or reports a run fault\u003c\/td\u003e\n\u003ctd\u003eCheck load\/brake condition and the separately approved motor-run setup. A feedback pass does not prove correct brake release, winding connection or phase order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eIncoming alignment, offsets and memory\u003c\/h2\u003e\n\u003cp\u003eBefore loosening, removing, resetting or programming the feedback, record the incoming mechanical reference, supported commutation\/alignment reading, motor pole count, direction and phase convention. Preserve drive offsets and parameters with readable encoder identity, memory\/status and offset data. Tie the record to the motor and encoder serials and the test setup.\u003c\/p\u003e\n\u003cp\u003eRetain or reproduce a \u003cstrong\u003evalid incoming alignment\u003c\/strong\u003e under the applicable specialist method, then verify it after refitting. Memory retention alone does not prove physical alignment. Where motor-specific memory decoding is unavailable, keep readable data without labelling a raw backup as a verified alignment value.\u003c\/p\u003e\n\u003cp\u003eIf the feedback was already disturbed, the reference is invalid, or memory is absent\/corrupt\/unreadable, record that limitation and obtain the motor-specific recovery method. No universal angle, automatic recovery, or default transfer from another motor is established here. Confirm hardware, data format and the complete motor order before any memory write.\u003c\/p\u003e\n\u003cp\u003eFor this multiturn SRM50 branch, preserve and assess the revolution count as well as the single-revolution reference.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe reviewed OEM-authored catalogue is KEBA document 0814.25B.8-00, 11\/2022. The current manufacturer motor page provides an LSN\/LST catalogue download. These references document the configuration; they do not establish stock, production status of every complete order, or a drop-in encoder successor. Confirm the complete motor and feedback labels and the applicable current drawing with the supplier before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor applications and related guides\u003c\/h2\u003e\n\u003cp\u003eG6.1S identifies SRS50 singleturn; G6.1M identifies SRM50 multiturn. The separate G6.2 family uses SKS36\/SKM36 with 128 analogue periods, while G7 options are HIPERFACE DSL. A generic “HIPERFACE” description is not enough to substitute those branches. LST and LSN are distinct motor families even where encoder options have the same names.\u003c\/p\u003e\n\u003cp\u003eRelated pages below provide additional identification context. A related guide is not a replacement or compatibility approval for this complete motor order.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.sparefaber.com\/products\/lti-lust-lsn-stegmann-hiperface-servo-feedback\" target=\"_blank\" rel=\"noopener\"\u003eLTI \/ Lust LSN Stegmann HIPERFACE Feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings and primary documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.parkem.ch\/fileadmin\/user_upload\/CrossData\/KEBA\/Catalogue_KEBA_LSN-LST_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKEBA LSN\/LST Servomotors Order Catalogue 0814.25B.8-00, 11\/2022\u003c\/a\u003e — K1 p.14 Table 1.3 (G6.1S\/M device\/fit), pp.66–67 (LST order and brake codes), pp.70–71 Table 3.15 (motor bases), p.87 (LST-097 G6.1x dimensions and brake), p.115 (G6.x M23 connector).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.keba.com\/download\/x\/78cef3992f\/0814-25b_lsn-lst-motor_kat_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKEBA official LSN\/LST catalogue download\u003c\/a\u003e — Manufacturer-hosted download; apply the document revision printed in the catalogue.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.keba.com\/en\/industrial-automation\/products\/motors\/overview-detail\" target=\"_blank\" rel=\"noopener\"\u003eKEBA synchronous servo motor page\u003c\/a\u003e — Manufacturer family context and catalogue download entry.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26697502947227-SICK-Stegmann-Hiperface-Serial-Encoders\" target=\"_blank\" rel=\"noopener\"\u003eMitchell: SICK Stegmann HIPERFACE Serial Encoders\u003c\/a\u003e — Device testing, connection, commutation, memory\/status and analogue signal assessment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/48944747309339-MOOG-Motors\" target=\"_blank\" rel=\"noopener\"\u003eMitchell: MOOG Motors\u003c\/a\u003e — Stegmann Absolute Encoders section; direct-to-encoder leads only, not a motor-specific adapter or alignment approval.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExact application evidence:\u003c\/strong\u003e K1 p.14 Table 1.3 (G6.1S\/M device\/fit), pp.66–67 (LST order and brake codes), pp.70–71 Table 3.15 (motor bases), p.87 (LST-097 G6.1x dimensions and brake), p.115 (G6.x M23 connector).\u003c\/p\u003e\n\u003cp\u003eSource scope reviewed 23 November 2026. Match the document revision, complete fitted labels and actual connector before using a drawing, replacement or test connection.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFAQ and service enquiry\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan this feedback be evaluated without an exact Mitchell motor entry?\u003c\/summary\u003e\u003cp\u003eYes, once the fitted device, supply and connection are positively identified within the documented feedback scope. Evaluate serial position and analogue signals and preserve valid incoming alignment\/memory. Motor-run approval remains a separate setup decision.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan I replace this option with the paired singleturn\/multiturn version?\u003c\/summary\u003e\u003cp\u003eG6.1S identifies SRS50 singleturn; G6.1M identifies SRM50 multiturn. The separate G6.2 family uses SKS36\/SKM36 with 128 analogue periods, while G7 options are HIPERFACE DSL. A generic “HIPERFACE” description is not enough to substitute those branches. LST and LSN are distinct motor families even where encoder options have the same names. Verify drive support, mounting, wiring, exact suffix and motor data before considering substitution.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information should accompany a service enquiry?\u003c\/summary\u003e\u003cp\u003eSend the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and service history. Include the cable labels and any saved incoming alignment\/data record. SpareFaber can then scope a UAE site investigation or send-in evaluation.\u003c\/p\u003e\u003c\/details\u003e\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or send-in evaluation\u003c\/a\u003e. Scope, parts and turnaround are confirmed after reviewing the fitted configuration and fault.\u003c\/p\u003e\u003c\/section\u003e","brand":"KEBA\/LTi","offers":[{"title":"Default Title","offer_id":51290446528677,"sku":"TCG1514","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/keba-lti-lst-097-4-g6-1m-srm50-feedback-technical-guide-service-card.png?v=1795407539","url":"https:\/\/www.sparefaber.com\/ar\/products\/keba-lti-lst-097-4-g6-1m-srm50-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}