{"product_id":"keba-lti-lst-190-1-resolver-feedback-technical-guide","title":"KEBA \/ LTi LST-190-1 Resolver 1R \/ 3R Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eKEBA \/ LTi LST-190-1\u003c\/strong\u003e with Resolver 1R \/ 3R is covered in this technical guide. Use it to identify the fitted assembly, compare the documented feedback branches, preserve incoming alignment and readable data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mechanical-fit\"\u003eMechanical fit\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDocuments\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted motor and feedback\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eIdentification item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eScoped information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ grouped base\u003c\/td\u003e\n\u003ctd\u003eKEBA \/ LTi LST-190-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTCG1711; SpareFaber service-guide reference, not an OEM part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame \/ family\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue M0 \/ stall reference\u003c\/td\u003e\n\u003ctd\u003e27 Nm; match the selected catalogue row, conditions and complete fitted order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ assembly\u003c\/td\u003e\n\u003ctd\u003eCatalogue LST build; identify any fitted external fan, brake and thermal option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor-data source\u003c\/td\u003e\n\u003ctd\u003eKEBA LSN\/LST motor table p.100; resolver compatibility p.14 and LST order code pp.66–67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical source\u003c\/td\u003e\n\u003ctd\u003ep.101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoverage boundary\u003c\/td\u003e\n\u003ctd\u003eresolver branch; base identifier omits complete speed\/winding\/shaft\/brake\/factory suffixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePhotograph the complete motor plate, serial, encoder label, feedback connector face and drive nameplate before disturbing the assembly. Record the actual brake, shaft, mounting, cooling, thermal sensor and speed\/winding fields. 1R \/ 3R — separate 1-pole-pair and 3-pole-pair subcases is the documented branch grouping used here; it is not a full factory order or an authorization to exchange devices.\u003c\/p\u003e\n\u003cp\u003e1R and 3R stay together in one motor-base resolver guide while their electrical cycle counts, scaling and actual device details remain distinct. Do not confuse resolver pole pairs with motor poles. Identify a fitted 1RY safety option separately; this guide does not validate a machine safety function.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDevice-level test scope:\u003c\/strong\u003e Use TI-5000JX resolver hardware with the lead verified for the fitted KEBA 1R or 3R connector and device. Record actual resolver speed, excitation and sine\/cosine pair polarity before interpreting the angle. A 3R resolver gives three electrical cycles per mechanical revolution, so a one-speed selection can give a misleading mechanical-angle display. TI-3011 may expose resolver signals for observation; it does not identify the correct motor-bulkhead lead or excitation by itself.\u003c\/p\u003e\n\u003cp\u003eRecord the tester hardware, lead\/module, software version, selected feedback type and actual fitted label with the report. First record the incoming fitted-device configuration and relevant position\/signal observations. Preserve supported readable identity and data before any write. A changing count or angle alone does not prove correct mechanical installation, signal quality, commutation sequence or drive configuration.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTest record\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat the observation establishes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabel and setup match\u003c\/td\u003e\n\u003ctd\u003eThe selected device, electrical interface and supply\/excitation match the identified branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlow manual movement\u003c\/td\u003e\n\u003ctd\u003eDirection, continuity, cyclic behaviour and the applicable index\/turn transition can be compared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation and secondaries\u003c\/td\u003e\n\u003ctd\u003eRecord primary excitation, secondary pairs, angle and vector behaviour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndependent signal checks\u003c\/td\u003e\n\u003ctd\u003eVerify sine\/cosine secondary polarity and behaviour through the actual cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBefore\/after report\u003c\/td\u003e\n\u003ctd\u003eIncoming configuration and each approved service change remain traceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eMotor-run scope:\u003c\/strong\u003e TI-5000JX feedback evaluation and TI-3000JX motor-run approval are separate decisions. Establish full motor parameters, pole count, phase convention, fixture\/load, brake handling and speed\/current limits before a run. A supported feedback protocol does not approve a run profile for this complete motor. No universal minimum firmware or exact motor-bulkhead adapter is asserted here.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eMotor data and resolver reference\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e1R branch\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e3R branch\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolver pole pairs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolver electrical cycles per mechanical turn\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScoped OEM compatibility\u003c\/td\u003e\n\u003ctd\u003eAll LST\u003c\/td\u003e\n\u003ctd\u003eFrom LST-050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal type\u003c\/td\u003e\n\u003ctd\u003eAnalogue excited resolver\u003c\/td\u003e\n\u003ctd\u003eAnalogue excited resolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAngle scaling\u003c\/td\u003e\n\u003ctd\u003eMatch the actual one-pole-pair setup\u003c\/td\u003e\n\u003ctd\u003eDo not apply one-pole-pair mechanical-angle scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation \/ fitted device\u003c\/td\u003e\n\u003ctd\u003eVerify actual label and matching device specification\u003c\/td\u003e\n\u003ctd\u003eVerify actual label and matching device specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn memory \/ serial identity\u003c\/td\u003e\n\u003ctd\u003eNo retained absolute ST\/MT claim\u003c\/td\u003e\n\u003ctd\u003eNo retained absolute ST\/MT claim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate options\u003c\/td\u003e\n\u003ctd\u003e1RY safety variant needs its own identification\u003c\/td\u003e\n\u003ctd\u003e5R is not listed as applicable to LST in the compatibility table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe catalogue torque reference for this grouped base is 27 Nm. It is used for identification and priority, not as momentary peak torque or a guaranteed rating for every speed\/winding\/cooling condition. Keep catalogue stall M0, rated Mn and short-duration Mmax separate. The selected 27 Nm row retains its published winding, thermal, mounting and cooling conditions.\u003c\/p\u003e\n\u003cp\u003eResolver 1R\/3R is analogue feedback rather than an ST\/MT serial absolute encoder. The 3R cycle count describes resolver speed, not three retained machine turns.\u003c\/p\u003e\n\u003cp\u003e1R and 3R stay together in one motor-base resolver guide while their electrical cycle counts, scaling and actual device details remain distinct. Do not confuse resolver pole pairs with motor poles. Identify a fitted 1RY safety option separately; this guide does not validate a machine safety function.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit, cooling and removal reference\u003c\/h2\u003e\n\u003cp\u003eCompare the 190-frame resolver\/1R\/3R length and drawing column on p.101. Brake, shaft, sealing, raised\/angled connector and feedback-holder options can alter the fitted assembly. Do not borrow a G6.x, G7.x or G12.x encoder length merely because the motor base matches.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFit item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRecord and compare\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange \/ pilot \/ mounting holes\u003c\/td\u003e\n\u003ctd\u003eUse the exact drawing and mounting version, including connector clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft \/ key \/ coupler\u003c\/td\u003e\n\u003ctd\u003eRecord actual dimensions, insertion depth and machine reference before removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder mounting\u003c\/td\u003e\n\u003ctd\u003eIdentify holder, coupling, fasteners and mechanical reference from the fitted device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake and fan\u003c\/td\u003e\n\u003ctd\u003eIdentify options and added envelope; verify their separate electrical circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeals \/ coolant \/ enclosure\u003c\/td\u003e\n\u003ctd\u003eMatch the actual cooling arrangement and ingress-protection build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eMark the incoming relationship between motor housing, feedback body, shaft and machine reference. Support the assembly without loading the encoder shaft or bearing through an improvised puller. Use the documented removal and assembly method for the fitted device; no unreviewed taper, fastening torque, air gap or insertion force is supplied by this grouped guide.\u003c\/p\u003e\n\u003cp\u003eMechanical drawings to compare: p.101. Connector orientation and holder variants can change practical clearance even where the nominal frame is the same. A similar-looking donor motor does not establish identical shaft, brake or encoder fit.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the actual 1R\/3R resolver connection and fitted connector build. The selected 190-frame drawing has a resolver length column; it is not a G6.x, G7.x or G12.x encoder pinout. The p.14 compatibility table lists 1R for all LST and 3R from LST-050; it marks 5R not applicable to LST despite a flattened generic order list containing 5R text.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCircuit \/ branch\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation and secondaries\u003c\/td\u003e\n\u003ctd\u003eTrace the actual primary, sine and cosine pairs using the fitted resolver drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1R versus 3R\u003c\/td\u003e\n\u003ctd\u003eConfirm resolver pole-pair count from the label\/order before setting mechanical-angle scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply assumptions\u003c\/td\u003e\n\u003ctd\u003eDo not apply the G3\/G5\/G12.x +5 V optical or G6.x classic-HIPERFACE supply table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor \/ feedback contacts\u003c\/td\u003e\n\u003ctd\u003eMatch connector keying, contact-side view, internal loom and screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther circuits\u003c\/td\u003e\n\u003ctd\u003eKeep brake, fan, thermal sensor, phases and protective earth separately identified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eRead connector drawings in their stated contact-side view and verify numbering, keyway, male\/female contacts and shell position. Check continuity with both ends isolated before applying feedback power. Photograph and label any repaired or custom loom so the test report identifies the actual route used.\u003c\/p\u003e\n\u003cp\u003eKeep motor phase conductors, brake supply, fan supply, protective earth, thermal circuits, encoder supply\/return and signal pairs distinct. Do not infer a pinout from wire colour, a shared connector shell, another manufacturer's motor or an electrically different feedback option. If a diagram caption and an order table disagree, resolve the actual fitted branch before energizing it.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eTest leads, internal loom and machine cable\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConnection layer\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat must be established\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect encoder plug\u003c\/td\u003e\n\u003ctd\u003eExact device connector and compatible bench lead; not automatically a motor-bulkhead connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor internal loom\u003c\/td\u003e\n\u003ctd\u003eContinuity, shielding, strain relief and any changes made during earlier repairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor feedback \/ hybrid bulkhead\u003c\/td\u003e\n\u003ctd\u003eCorrect socket, contact view, branch and separate power\/brake\/thermal circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine cable\u003c\/td\u003e\n\u003ctd\u003eBoth endpoint pinouts, length\/routing, drag-chain damage and shield termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive \/ tester end\u003c\/td\u003e\n\u003ctd\u003eCorrect installed selection, supply module and interface-specific lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eA device that reads correctly with a direct plug but fails through the motor can point to the internal loom or bulkhead route. A device that works at the motor but fails through the machine harness requires an endpoint-by-endpoint cable check. Document which layer was bypassed; do not report a complete motor or machine harness as proven from a direct encoder test.\u003c\/p\u003e\n\u003cp\u003eKeep excitation and both secondary pairs identified through each cable layer. Check winding continuity and polarity against the fitted drawing; do not apply a DC encoder-supply assumption to the resolver.\u003c\/p\u003e\n\u003cp\u003eNo complete machine-cable part number or universal lead is assigned to every configuration in this guide. Select or document the cable only after the complete motor\/encoder labels and both connector endpoints are known.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eDiagnostic symptoms and useful comparisons\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eReported symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEvidence to collect before changing parts\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo angle \/ unstable angle\u003c\/td\u003e\n\u003ctd\u003eFitted excitation, primary\/secondary continuity, polarity, resolver speed and lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition changes but drive faults remain\u003c\/td\u003e\n\u003ctd\u003eStatus codes, configuration, motor-data interpretation and phase\/alignment relationship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent or noisy behaviour\u003c\/td\u003e\n\u003ctd\u003eConnector contact, strain\/routing, shield integrity and signal quality through each cable layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncorrect direction or scaling\u003c\/td\u003e\n\u003ctd\u003eRecorded device direction, selected protocol\/word format and drive scaling; do not rewrite offsets to hide it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine reference \/ scaling unexpected\u003c\/td\u003e\n\u003ctd\u003eResolver speed, controller offset, direction and machine multi-revolution reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault appeared after removal\u003c\/td\u003e\n\u003ctd\u003eOriginal reference marks, mechanical holder\/shaft relationship, supported offsets and before\/after reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eCompare one identified path at a time: direct encoder, internal loom, motor bulkhead, then machine cable\/drive. Retain the original symptom, fault codes and setup with each result. An isolated cable fault, an unsupported test selection and a damaged encoder can present a similar initial symptom.\u003c\/p\u003e\n\u003cp\u003eA resolver angle is affected by excitation, winding polarity and resolver speed. Keep resolver speed independent of motor poles, and compare secondary\/vector behaviour before changing a controller offset.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, offsets and memory preservation\u003c\/h2\u003e\n\u003cp\u003eCapture the incoming shaft\/machine reference, device label, drive offsets, direction and the relevant angle\/index\/commutation relationship before removal. Preserve controller configuration and the homing\/reference method with a report identifying the fitted device, fixture, lead and selected test setup.\u003c\/p\u003e\n\u003cp\u003eAfter mechanical work, check the fitted encoder's mounting and signal quality before interpreting an angle. A wrong cable\/selection or an unstable mechanical fit can make an otherwise valid offset appear incorrect. Do not copy an angle, memory image or motor profile from another motor merely because its frame or protocol matches.\u003c\/p\u003e\n\u003cp\u003eThe resolver\/incremental interface does not establish serial encoder memory or a retained multiturn turn counter. Preserve available controller offsets, reference\/homing data and mechanical alignment through the application-specific workflow. Do not apply an absolute-encoder memory image to this device.\u003c\/p\u003e\n\u003cp\u003eIf the original relationship or data is unavailable, define a motor-specific recovery method from documented motor\/feedback information and the installed test system. This guide does not prescribe a universal lock-up angle, firmware threshold, phase convention or replacement memory file. Record the before\/after evidence and the exact change performed.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eService scope, replacement and availability\u003c\/h2\u003e\n\u003cp\u003eThis is a technical-guide\/service listing for KEBA \/ LTi LST-190-1, not a claim that a complete motor, encoder, brake, fan or cable is held in stock. Parts and service scope follow review of the full fitted labels, connector photos, fault report and required operating conditions.\u003c\/p\u003e\n\u003cp\u003eA replacement decision must compare interface, absolute\/analogue behaviour, supply, mounting, shaft\/holder, connector route, thermal\/brake options, supported motor data and drive compatibility. A motor-base match alone does not establish a drop-in replacement. Catalogue inclusion does not prove current production, exact-order availability, turnaround or certification.\u003c\/p\u003e\n\u003cp\u003eProvide clear label and connector photographs plus the reported symptom and any previous repair changes for a scoped UAE site visit or send-in evaluation. The service quotation can then identify the assessment, repair, alignment or installation work and any parts that require confirmation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eApplications and practical service enquiries\u003c\/h2\u003e\n\u003cp\u003eThe selected 190 frame\/family and 27 Nm catalogue reference place this guide in the identified motor range; they do not rate a new machine duty. Typical enquiries concern feedback faults, connector\/loom repair, motor replacement identification, reinstallation after mechanical work and preservation of existing alignment\/data.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompare the exact motor and feedback branch during a repair intake.\u003c\/li\u003e\n\u003cli\u003eDocument a cable-versus-encoder investigation before replacing an otherwise serviceable assembly.\u003c\/li\u003e\n\u003cli\u003ePrepare an installation or reinstallation visit with complete labels, drive details and machine reference.\u003c\/li\u003e\n\u003cli\u003eAssess an identified replacement against the actual shaft, cooling, brake, connector and data requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse the documents below and the exact fitted-label evidence when comparing another interface or motor base.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest installation, repair or alignment assessment\u003c\/a\u003e and include reference \u003cstrong\u003eTCG1711\u003c\/strong\u003e.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.keba.com\/download\/x\/78cef3992f\/0814-25b_lsn-lst-motor_kat_en.pdf\"\u003eKEBA LSN\/LST order catalogue 0814.25B.8-00, 11\/2022\u003c\/a\u003e — \u003ca href=\"https:\/\/device.report\/m\/56857c9a0a12baa63b826e97ac8d73075a8850168e372b961d65c9dab805164b\"\u003ereadable reproduction of the OEM catalogue\u003c\/a\u003e. KEBA LSN\/LST motor table p.100; resolver compatibility p.14 and LST order code pp.66–67. Mechanical reference: p.101.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26578514023963-Generic-Resolvers\"\u003eMitchell generic resolver testing\u003c\/a\u003e. Verify resolver speed, excitation convention and the actual compatible lead.\u003c\/li\u003e\n\u003cli\u003eResolver compatibility p.14; LST order fields pp.66–67; motor data p.100 and drawing p.101. Resolve the complete actual resolver connector\/device before choosing a cable or excitation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese references support the scoped family and documented options. The complete fitted order and actual device revision determine the final wiring, envelope, software selection and service method. Keep the source edition\/page, nameplate photos and measured setup with the report so a later technician can reproduce the identification.\u003c\/p\u003e\n\u003cp\u003eThe cover is a branded service illustration with concise headings. It is not an OEM dimensional drawing or proof of the exact motor\/encoder installed in a machine.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a complete factory motor order?\u003c\/h3\u003e\n\u003cp\u003eNo. KEBA \/ LTi LST-190-1 is a guide grouping. Match all winding\/speed, shaft, mounting, cooling, brake, feedback and custom-order fields on the actual plates.\u003c\/p\u003e\n\u003ch3\u003eDoes this resolver retain a multiturn position?\u003c\/h3\u003e\n\u003cp\u003eThe resolver supplies angle within its electrical cycle. Controller offsets and machine multi-revolution reference are separate application data.\u003c\/p\u003e\n\u003ch3\u003eCan I use another motor's cable or test selection?\u003c\/h3\u003e\n\u003cp\u003eOnly after the actual device, supply, complete endpoint wiring and installed support are established. A shared shell, frame or protocol name is not enough.\u003c\/p\u003e\n\u003ch3\u003eDoes feedback testing prove a motor-run setup?\u003c\/h3\u003e\n\u003cp\u003eNo. Exact motor parameters, fixture\/load, brake and phase\/alignment conventions require their own motor-specific run-test approval.\u003c\/p\u003e\n\u003ch3\u003eCan the original alignment and data be preserved?\u003c\/h3\u003e\n\u003cp\u003eCapture available incoming identity, mechanical reference, supported angles\/offsets and readable data before removal or writes. Recovery after missing data requires a defined motor-specific method.\u003c\/p\u003e\n\u003ch3\u003eHow do I request service?\u003c\/h3\u003e\n\u003cp\u003eSend full motor and encoder labels, connector photographs, drive details, fault symptoms and previous repair changes with TCG1711. Installation, repair, alignment and site\/send-in scope follow identification.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eSend a service enquiry for TCG1711\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e","brand":"KEBA\/LTi","offers":[{"title":"Default Title","offer_id":51296738869413,"sku":"TCG1711","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/tcg1711-keba-lti-lst-190-1-resolver-feedback-technical-guide-cover.jpg?v=1795446982","url":"https:\/\/www.sparefaber.com\/ar\/products\/keba-lti-lst-190-1-resolver-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}