{"product_id":"kollmorgen-akm-ab-biss-b-multiturn-feedback","title":"Kollmorgen AKM AB BiSS-B Multiturn Servo Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eRead AB in the feedback field of the complete Kollmorgen AKM order. The BiSS-B multiturn option carries a turn field as well as position within one revolution.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Kollmorgen AKM AB BiSS-B Multiturn Servo Feedback technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Mitchell lists BiSS for AKM. Confirm the exact encoder, BiSS-B selection and fixture on TI-5000JX.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Mitchell lists AKM BiSS among supported motor options. Verify the actual encoder profile, motor poles and fixture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e Use the verified AKM AB connector and fitted BiSS-B encoder fixture.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eKollmorgen AKM AB BiSS-B Multiturn Servo Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAKM AB\u003c\/th\u003e\n\u003ctd\u003eKollmorgen’s BiSS-B multiturn optical option. Confirm the exact fitted Hengstler label and drive.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAKM AA\u003c\/th\u003e\n\u003ctd\u003eSingleturn BiSS-B branch in the same model key. Compare the full order and field structure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAKM DA \/ DB\u003c\/th\u003e\n\u003ctd\u003eThe EnDat 2.1 family has its own wiring and setup. Use the model key to select the actual protocol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eBiSS-B on AB in the OEM code table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition data\u003c\/th\u003e\n\u003ctd\u003eAbsolute within-turn position and a turn field. Confirm the fitted encoder resolution and frame.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical and connection scope\u003c\/th\u003e\n\u003ctd\u003eAKM motor frame, connector option and encoder model are separate fields. Verify all three.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe receiver exchanges clock and data with the BiSS-B encoder and decodes its position and turn fields. Verify exact frame and word lengths before treating unexpected counts as a fault.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the actual AKM motor outline and fitted Hengstler drawing for shaft, restraint and connector position. Record the original installation before changing the reference.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eChoose the AKM connectivity view for the actual motor, drive and connector code. Identify clock\/data, supply and return and any fitted analogue channels. Confirm the configured protocol on the receiver.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eFind the machine cable from the exact motor and drive pairing. Identify the OEM internal loom from the fitted feedback plug and motor revision.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWithin-turn position reads and revolutions are wrong\u003c\/th\u003e\n\u003ctd\u003eCheck that AB is fitted and that the drive expects the corresponding turn field.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo valid data frame\u003c\/th\u003e\n\u003ctd\u003eVerify BiSS-B profile, matching connector and clock\/data paths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition jumps after service\u003c\/th\u003e\n\u003ctd\u003eCheck shaft engagement, mounting and saved reference before changing drive parameters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003ePreserve original reference, turn data and motor settings. Verify both within-turn position and rollover under the OEM commissioning procedure after fitting.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eKollmorgen AKM with AB code\u003c\/p\u003e\n\u003cp\u003eObtain full motor order, exact Hengstler ID, frame format and starting lead.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/ar\/products\/hengstler-ad58-0547029-biss-b\"\u003eHengstler AD58\/0022E1.0KBI0 0547029 BiSS-B Encoder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ar\/products\/beckhoff-am3-biss-motor-feedback\"\u003eBeckhoff AM3 BiSS Servo Motor Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4409347607963-Kollmorgen-AKM-support\"\u003eKollmorgen AKM support\u003c\/a\u003e. Supported feedback and linked AKM code table\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/public_downloads\/akm_connectivity_en_1.pdf\"\u003eKollmorgen AKM connectivity manual\u003c\/a\u003e. Feedback code and connector scope for the fitted AKM.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kollmorgen.com\/en-us\/developer-network\/akm-motor?page=0\"\u003eKollmorgen AKM product and feedback key\u003c\/a\u003e. AA and AB code mapping.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/article_attachments\/5104769779867\"\u003eMitchell-linked AKM feedback table\u003c\/a\u003e. Model-dependent BiSS-B branches.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51128919752869,"sku":"TCG246","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/kollmorgen-akm-ab-biss-b-multiturn-feedback-service-guide.jpg?v=1794253078","url":"https:\/\/www.sparefaber.com\/ar\/products\/kollmorgen-akm-ab-biss-b-multiturn-feedback","provider":"SpareFaber","version":"1.0","type":"link"}