{"product_id":"kollmorgen-akm21e-bnm2c-00-sfd-internal-resolver-feedback","title":"Kollmorgen AKM21E-BNM2C-00 Legacy SFD Internal Resolver | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eOn this AKM21E, the resolver and the legacy SFD converter form two different diagnostic paths. Mitchell shows how the internal resolver can be assessed during specialist alignment work.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Kollmorgen AKM21E-BNM2C-00 Legacy SFD Internal Resolver technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e TI-5000JX on the isolated internal resolver with TI-5928 and the documented setup. The proprietary four-wire SFD data remains a separate diagnostic path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e The exact linked case establishes direct resolver checks and alignment. Confirm the motor, fixture and approved run setup with a specialist before any powered rotation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e TI-5928 at the documented internal resolver connector. Module Resolver input via the verified TI-5928 fixture.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eKollmorgen AKM21E-BNM2C-00 Legacy SFD Internal Resolver technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAKM21E-BNM2C-00\u003c\/th\u003e\n\u003ctd\u003eExact legacy SFD motor in Mitchell’s linked case. Verify the full label and converter assembly before opening the feedback end.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal 8-contact resolver plug\u003c\/th\u003e\n\u003ctd\u003eMitchell identifies this as the TI-5928 diagnostic connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal four-wire SFD connection\u003c\/th\u003e\n\u003ctd\u003eThe fitted converter produces a proprietary serial output. Mitchell documents the direct resolver path separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFitted feedback architecture\u003c\/th\u003e\n\u003ctd\u003ePassive resolver feeds a converter PCB in the legacy SFD assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDirect connection\u003c\/th\u003e\n\u003ctd\u003eInternal 8-contact resolver connection and the TI-5928 drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive-side output\u003c\/th\u003e\n\u003ctd\u003eLegacy four-wire SFD serial. The direct resolver test assesses a different circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eAC excitation and the resolver’s sine and cosine returns are processed by the SFD board. A good resolver trace can coexist with an SFD drive alarm. Continue with the converter, external harness and drive receiver if the internal path checks out.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the exact AKM motor case and feedback assembly drawing. Record the original resolver relationship and cable dressing before a bearing change. Support the motor and avoid loading the connector or the converter PCB during service.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the TI-5928 drawing for the internal resolver plug. Use the Kollmorgen wiring for the external SFD connector. Trace the excitation and return windings as separate circuits on the approved fixture.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eThe internal resolver-to-PCB link and the external motor-to-drive feedback cable carry different signals. Record both plug views and the external cable assembly. The TI-5928 part number identifies the Mitchell diagnostic lead.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eA resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSFD alarms with stable internal resolver returns\u003c\/th\u003e\n\u003ctd\u003eCheck the converter, external cable and drive receiver with the correct SFD documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoth resolver returns weak\u003c\/th\u003e\n\u003ctd\u003eVerify excitation and the internal harness first. Check the isolated winding circuit against the case drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault started after a bearing change\u003c\/th\u003e\n\u003ctd\u003eReview resolver seating, cable routing and the incoming alignment record.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eKeep the incoming reference and compare it with the AKM21E-BNM2C-00 case. Record polarity, direction and the actual resolver setting before disturbing the assembly. A specialist can verify alignment on the documented direct-resolver setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eKollmorgen AKM legacy SFD\u003c\/p\u003e\n\u003cp\u003eIsolate a resolver or alignment problem from a possible SFD converter fault.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/ar\/products\/kollmorgen-akm2g-sfd3\"\u003eKollmorgen AKM2G SFD3 CA Motor Feedback- Technical Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/ar\/products\/kollmorgen-akm-da-db-endat-2-1-feedback\"\u003eKollmorgen AKM DA \/ DB EnDat 2.1 Servo Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4410195398811-Kollmorgen-AKM-motors-with-SFD-feedback\"\u003eKollmorgen AKM motors with SFD feedback\u003c\/a\u003e. Linked AKM21E-BNM2C-00 example and 8-contact resolver connection\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.dropbox.com\/s\/l0uryyexg1jccyk\/Kollmorgen_AKM21E-BNM2C-00_SFD.pdf?dl=0\"\u003eMitchell AKM21E-BNM2C-00 SFD motor case\u003c\/a\u003e. Supplementary reference for the stated model or setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bobcat-mei.nyc3.digitaloceanspaces.com\/part_pdf\/561_TI-5928.pdf?u=20241212103121\"\u003eMitchell TI-5928 resolver test cable drawing\u003c\/a\u003e. Use the documented internal plug and pin view for the AKM SFD resolver.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4409347607963-Kollmorgen-AKM-support\"\u003eMitchell AKM support\u003c\/a\u003e. AKM option and resolver-path scope, including legacy SFD and SFD3.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51131190509733,"sku":"TCG258","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/kollmorgen-akm21e-bnm2c-00-sfd-internal-resolver-feedback-service-guide.jpg?v=1794277520","url":"https:\/\/www.sparefaber.com\/ar\/products\/kollmorgen-akm21e-bnm2c-00-sfd-internal-resolver-feedback","provider":"SpareFaber","version":"1.0","type":"link"}