{"product_id":"kollmorgen-akm2g-sfd3","title":"Kollmorgen AKM2G SFD3 CA Motor Feedback- Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eAKD2G fails to recognize an AKM2G motor?\u003c\/strong\u003e SpareFaber can inspect the SFD3 hybrid connector, cable and drive configuration at your UAE site. Send the motor and exact cable details for compatibility and feedback evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Kollmorgen AKM2G SFD3 CA Motor Feedback technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the entire motor code including the connector and feedback characters, AKD2G model and firmware, fault text and the cable marking. Include whether the fault began after a motor, drive or cable change. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a supported Kollmorgen drive and matching cable to read motor identity, feedback type, position and diagnostics. Compare the fault with a verified cable or approved service fixture. Mitchell states that its JX equipment does not directly decode proprietary SFD or SFD3 serial. A published resolver-side bypass applies only where the matching internal assembly and procedure are verified, and it cannot validate the SFD3 serial path. \u003ca href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g_user_manual\/Feedback_About_Types.htm\"\u003eAKD2G supported feedback types\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4409347607963-Kollmorgen-AKM-support\"\u003eMitchell scope for SFD\/SFD3 bench work\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eKollmorgen AKM2G SFD3 CA Motor Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead the full \u003cstrong\u003eAKM2G motor type\u003c\/strong\u003e, the \u003cstrong\u003eCA\u003c\/strong\u003e feedback code and the separate connector code. This guide focuses on CA with the D hybrid connector, with other codes as comparisons. The servo name, SFD family and external connector are each needed to identify a replacement.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"AKM2G feedback and hybrid connector examples\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eAKM2G feedback and hybrid connector examples\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eNameplate combination\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFeedback\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eConnector distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCA · D\u003c\/th\u003e\n\u003ctd\u003eSFD3, two-wire absolute singleturn\u003c\/td\u003e\n\u003ctd\u003eD hybrid under 20 A continuous in the cited pinout. SFD pair H\/L.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCA · A\u003c\/th\u003e\n\u003ctd\u003eSame SFD3 feedback protocol\u003c\/td\u003e\n\u003ctd\u003eLegacy AKM cable pinning on applicable AKM2G. SFD pair C\/D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCA · J\u003c\/th\u003e\n\u003ctd\u003eSame SFD3 feedback protocol\u003c\/td\u003e\n\u003ctd\u003eSeparate J hybrid for AKM2G7 \u0026gt;20 A in the cited pinout. SFD pair 6\/7.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCB · SFD-M\u003c\/th\u003e\n\u003ctd\u003eTwo-wire absolute multiturn\u003c\/td\u003e\n\u003ctd\u003eUse the specific CB motor and connector documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGU · HIPERFACE DSL\u003c\/th\u003e\n\u003ctd\u003eDifferent two-wire feedback system\u003c\/td\u003e\n\u003ctd\u003eConfirm its dedicated connector, drive setup and cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-07\/AKM2G-Install-Manual-Multilingual.pdf\"\u003eAKM2G feedback options (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-01\/AKM2G-SG_KM_000315_RevD_EN.pdf\"\u003eKollmorgen connector drawings (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g_user_manual\/Feedback_About_Types.htm\"\u003eAKD2G feedback types\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eKollmorgen's AKM2G installation and feedback documentation list SFD3 code CA. Confirm current manufacture, repair and replacement for the complete motor and connector code. \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-07\/AKM2G-Install-Manual-Multilingual.pdf\"\u003eKollmorgen AKM2G options (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SFD3 CA application characteristics\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSFD3 CA application characteristics\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eSingleturn absolute feedback. Kollmorgen describes a resolver sensing element with digital electronics in SFD3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive link\u003c\/th\u003e\n\u003ctd\u003eTwo wires carrying DC power and AC-coupled proprietary serial communication on an RS-485 physical link.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData\u003c\/th\u003e\n\u003ctd\u003eShaft position, motor temperature and motor catalog parameters stored in the feedback device as documented by Kollmorgen.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAKD2G feedback type\u003c\/th\u003e\n\u003ctd\u003eSFD3 is type 45 in the cited AKD2G manual. SFD-M is a separate type.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical and supply details\u003c\/th\u003e\n\u003ctd\u003eBuilt into the AKM2G motor. Use the specific motor drawings and Kollmorgen drive\/cable for interface electrical limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.kollmorgen.com\/en-us\/developer-network\/sfd3\"\u003eKollmorgen SFD3 architecture\u003c\/a\u003e · \u003ca href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g_user_manual\/Feedback_About_Types.htm\"\u003eAKD2G type descriptions\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-07\/AKM2G-Install-Manual-Multilingual.pdf\"\u003eAKM2G temperature and option notes (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eSFD3 is internal to the motor. First confirm whether the fault follows the external cable or drive input before opening the motor. Check the hybrid connector key, lock, shell and strain relief under isolation. Preserve the original feedback position and connector arrangement. Request motor-specific internal mechanical and service drawings before moving the resolver, board or motor end cover. \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-07\/AKM2G-Install-Manual-Multilingual.pdf\"\u003eKollmorgen motor installation and handling (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-01\/AKM2G-SG_KM_000315_RevD_EN.pdf\"\u003eExternal connector and configuration (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eSFD3 and the drive share the feedback pair for power and communications. At startup the drive can read the motor's identity and stored parameters. A connector can look similar to a DSL or another SFD version while using a different protocol or contact assignment. A normal shaft angle at one position does not establish communication or motor identity across the service range. \u003ca href=\"https:\/\/www.kollmorgen.com\/en-us\/developer-network\/sfd3\"\u003eKollmorgen two-wire interface and data\u003c\/a\u003e · \u003ca href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g_user_manual\/Feedback_About_Types.htm\"\u003eDrive feedback compatibility\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThese are the \u003cstrong\u003emotor-end feedback contacts only\u003c\/strong\u003e in Kollmorgen's named hybrid drawings. The same connector carries motor power and may carry brake wiring. Fit the correct factory cable and read the exact motor and drive diagrams before connecting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SFD3 motor connector feedback contacts\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSFD3 motor connector feedback contacts\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMotor connector option\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSFD3 +\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSFD3 −\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eD hybrid, AKM2G \u0026lt;20 A continuous\u003c\/th\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA legacy hybrid, applicable AKM2G 2–7 ≤20 A\u003c\/th\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJ hybrid, AKM2G7 \u0026gt;20 A\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe D, A and J views in the manufacturer document show different power and brake contacts. The plus and minus above identify the combined feedback circuit. Use only the supported drive and cable for power and test. \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-01\/AKM2G-SG_KM_000315_RevD_EN.pdf\"\u003eKollmorgen hybrid motor connector pinouts (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eFor \u003cstrong\u003eCA with the D SpeedTec connector\u003c\/strong\u003e and the AKD2G drive\/current combinations shown in the Kollmorgen lookup (RMS \u0026lt;15 A in that row), the catalogue gives \u003cstrong\u003eH2-21-015-A1-00-XXXX00\u003c\/strong\u003e PUR and \u003cstrong\u003eH6-21-015-A1-00-XXXX00\u003c\/strong\u003e PVC patterns. Check the exact drive family and current rating and fill the length from the catalogue. The legacy A uses legacy AKM wiring. Internal sensor-to-board parts and machine-specific bulkheads require an OEM lookup. \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/AMC-KM_CA_000246_RevG_EN-mobile.pdf\"\u003eKollmorgen SFD3 2G cable lookup (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-01\/AKM2G-SG_KM_000315_RevD_EN.pdf\"\u003eLegacy A and alternate connector notes (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate the complete hybrid circuit before unplugging it.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. The hybrid connector carries drive power as well as feedback. Follow the manufacturer discharge procedure.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord.\u003c\/strong\u003e Capture the fault, recognized motor type, axis and feedback connector assignment before resetting. Compare the nameplate and full cable code.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check the correct keyed shell, seating, loose pins, damaged seal, strain or coolant ingress. Check the motor and load for a separate coupling or mechanical issue while isolated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the disconnected cable.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Use the exact hybrid cable drawing to identify the feedback pair, including its separation from phase and brake conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate the path by substitution.\u003c\/strong\u003e On an approved drive and test setup, compare with a verified identical cable and intended port. If a known-compatible drive still fails to identify the motor after the cable path is verified, specialist internal evaluation is appropriate. Communication with an incorrect motor identity calls for checking firmware and stored configuration.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eFor AKM2G servomotors built with CA SFD3. Confirm the drive's supported feedback input and hardware revision using the AKD2G manual. Separate SFD, SFD-M and HIPERFACE DSL options have their own drive requirements. \u003ca href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g_user_manual\/Feedback_About_Types.htm\"\u003eKollmorgen AKD2G feedback support\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/AMC-KM_CA_000246_RevG_EN-mobile.pdf\"\u003eMotor-to-drive cable lookup (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCapture motor identity, drive parameters, original feedback orientation and the verified motor-specific commutation reference before repair. Refer internal reinstallation, memory work and commutation verification to the matching Kollmorgen service procedure. After approved work, confirm correct identification, direction and commutation in a controlled test, then establish the machine datum separately. \u003ca href=\"https:\/\/www.kollmorgen.com\/en-us\/developer-network\/sfd3\"\u003eKollmorgen stored motor data\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-07\/AKM2G-Install-Manual-Multilingual.pdf\"\u003eAKM2G commissioning and documentation (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-07\/AKM2G-Install-Manual-Multilingual.pdf\"\u003eKollmorgen AKM2G Installation Manual (PDF)\u003c\/a\u003e. Motor code and feedback options, connector families and installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/2025-01\/AKM2G-SG_KM_000315_RevD_EN.pdf\"\u003eKollmorgen AKM2G motor connector pinouts (PDF)\u003c\/a\u003e. Separate A, D, E and J diagrams.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/AMC-KM_CA_000246_RevG_EN-mobile.pdf\"\u003eKollmorgen 2G cable lookup (PDF)\u003c\/a\u003e. Check motor and drive combination before ordering a hybrid.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g_user_manual\/Feedback_About_Types.htm\"\u003eKollmorgen AKD2G feedback types\u003c\/a\u003e. Verify the intended drive interface and recognition.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4409347607963-Kollmorgen-AKM-support\"\u003eMitchell Kollmorgen AKM support\u003c\/a\u003e. Equipment-specific support boundaries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51118252785829,"sku":"tyu4","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/KollmorgenAKM2GSFD3CAMotorFeedback-TechnicalGuideServiceVisitforInstallation_Repair_Alignment.jpg?v=1794120490","url":"https:\/\/www.sparefaber.com\/ar\/products\/kollmorgen-akm2g-sfd3","provider":"SpareFaber","version":"1.0","type":"link"}