{"product_id":"kubler-sendix-5863-ssi","title":"Kübler Sendix 5863 SSI Multiturn Encoder  | Technical Guide| Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eSSI link active but the position is wrong?\u003c\/strong\u003e SpareFaber can visit your UAE site to check the Sendix 5863 supply, clock and data pairs, coupling and receiver settings. Ask about bench checks of the exact encoder and cable.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Kübler Sendix 5863 SSI Multiturn Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the full 8.5863 order number, shaft and connector photos, SSI receiver model and your current clock, code, singleturn and multiturn settings. Note if the position jumps at a turn boundary or after a replacement. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA compatible SSI reader or controller can check position, direction and repeatability over several turns. A qualified technician can compare CLOCK and DATA with an appropriate differential scope and check that the receiver uses the same bit length and code. Compare behavior at a slower supported clock to help isolate a cable or termination problem. Exact Sendix 5863 support for Mitchell TI-5000JX and a TI-3000JX run profile were not verified. \u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=3\"\u003eKübler SSI timing and ratings (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/download.beckhoff.com\/download\/document\/io\/ethercat-terminals\/EL500x_en.pdf\"\u003eBeckhoff SSI commissioning (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eKübler Sendix 5863 SSI Multiturn Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead the full Kübler order code. \u003cstrong\u003e8.5863\u003c\/strong\u003e is the solid-shaft series. In \u003cstrong\u003e8.5863.112A.G323.0030\u003c\/strong\u003e, the illustrated code selects the IP65 clamping flange, Ø6 × 10 mm shaft, 10–30 V interface, axial special-length lead, SSI Gray format, 13 singleturn and 12 multiturn bits, and the SET button\/status LED option. The final 0030 is a 3 m lead.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference SSI build and order-code differences\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eReference SSI build and order-code differences\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or ordering field\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat it selects\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePractical implication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8.5863.112A.G323.0030\u003c\/th\u003e\n\u003ctd\u003eManufacturer order example. Gray SSI, 13 ST + 12 MT, 10–30 V DC, 3 m lead.\u003c\/td\u003e\n\u003ctd\u003eUse the cable map for interface 2 and connection A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8.5863 · code B \/ G\u003c\/th\u003e\n\u003ctd\u003eSSI binary \/ SSI Gray in the code position\u003c\/td\u003e\n\u003ctd\u003eSelect the corresponding format in the receiver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8.5863 · code C\u003c\/th\u003e\n\u003ctd\u003eBiSS binary in the same code position\u003c\/td\u003e\n\u003ctd\u003eUse the BiSS documentation for the full unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8.5883\u003c\/th\u003e\n\u003ctd\u003eHollow-shaft companion series\u003c\/td\u003e\n\u003ctd\u003eSeparate coupling and flange drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eRead the interface and connector fields together. Some 5863s have extra SinCos or RS422 incremental signals and others have remote supply sense. \u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=1\"\u003eKübler order-code and length example (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eKübler lists Sendix 5863 and publishes a December 2025 data sheet. Ask for current orderability and an approved successor for the full code and any special length or approval. Reviewed 7 November 2026. \u003ca href=\"https:\/\/www.kuebler.com\/en\/products\/measurement\/encoders\/product-finder\/product-details\/5863\"\u003eKübler 5863 product page\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"5863 reference build and SSI ratings\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003e5863 reference build and SSI ratings\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue \/ scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eOptical absolute with mechanical multiturn gearing, battery-free turn counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWord capacity\u003c\/th\u003e\n\u003ctd\u003e13 singleturn bits (8192 positions) plus 12 multiturn bits (4096 turns) on the reference build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e10–30 V DC for interface code 2, maximum 50 mA without load per the data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSSI clock\u003c\/th\u003e\n\u003ctd\u003e50 kHz–2 MHz encoder range. Use a supported value for the receiver and cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition timing\u003c\/th\u003e\n\u003ctd\u003e≤1 µs data refresh for singleturn resolutions up to 14 bits. SSI monoflop time ≤15 µs in the datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical reference\u003c\/th\u003e\n\u003ctd\u003eØ58 mm IP65 clamping flange, Ø6 h7 × 10 mm shaft with flat. The cited cable-version temperature is −30 to +75 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=3\"\u003eMechanical and electrical specifications (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=6\"\u003eSolid-shaft drawing (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eFix the clamping flange to the machine register and connect the solid encoder shaft to the machine with an appropriate flexible coupling. Use the actual shaft diameter, exposed length and flat. Check that the coupling has room to flex within its alignment limits and cannot slide. Side load from a misaligned coupling can give intermittent motion and shorten bearing life. Confirm the correct fixing pattern from flange type 1\/3 or the other drawing if the label specifies a different flange.\u003c\/p\u003e\n\u003cp\u003eThe 5883 hollow-shaft series uses a separate arrangement. Its clamp-ring torque does not describe the 5863 coupling. Record shaft and machine datum before removal. \u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=6\"\u003e5863 solid-shaft mating drawings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eSSI is a clocked, point-to-point link. The receiver supplies differential CLOCK and the encoder shifts its position word back on differential DATA. The receiver interprets the singleturn and turn fields using the configured bit length and code. A live DATA signal can still decode to jumping or doubled counts if the Gray\/binary selection or field alignment is wrong.\u003c\/p\u003e\n\u003cp\u003eFor the reference build, start from 13 singleturn plus 12 multiturn bits and verify framing in the receiver. Set the interval between transactions to allow a new sample. Kübler notes that clocking again within the monoflop window can repeat the same value.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the cable row for interface codes 1\/2 and termination A, and the connector drawing if yours has a plug. The M12 table applies only to the documented 8-pin type 5\/6. Kübler’s connector figure shows the male mating face.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Kübler base SSI interface 1\/2. Reference build uses the flying lead column.\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eKübler base SSI interface 1\/2. Reference build uses the flying lead column.\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCable colour\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eM23 12-pin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eM12 8-pin\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e0 V \/ +V\u003c\/th\u003e\n\u003ctd\u003eWhite \/ brown\u003c\/td\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCLOCK+ \/ CLOCK−\u003c\/th\u003e\n\u003ctd\u003eGreen \/ yellow\u003c\/td\u003e\n\u003ctd\u003e3 \/ 4\u003c\/td\u003e\n\u003ctd\u003e3 \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDATA+ \/ DATA−\u003c\/th\u003e\n\u003ctd\u003eGray \/ pink\u003c\/td\u003e\n\u003ctd\u003e5 \/ 6\u003c\/td\u003e\n\u003ctd\u003e5 \/ 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSET \/ DIR\u003c\/th\u003e\n\u003ctd\u003eBlue \/ red\u003c\/td\u003e\n\u003ctd\u003e7 \/ 8\u003c\/td\u003e\n\u003ctd\u003e7 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eERR status\u003c\/th\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eNot assigned on this 8-pin map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShield\u003c\/th\u003e\n\u003ctd\u003eScreen\u003c\/td\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eKübler specifies tying an unused SET input to encoder 0 V on this family. Verify the intended DIR state and keep unassigned cores isolated. Avoid operating SET during diagnosis until the original datum has been recorded and the machine procedure permits a reset. \u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=4\"\u003eSET and direction behavior (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=5\"\u003eWiring and mating views (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe reference code has a factory 3 m axial PVC open-end lead, ordered as \u003cstrong\u003e.0030\u003c\/strong\u003e on connection A. The data sheet lists special lengths and optional 8-pin M12 or 12-pin M23 builds. This is an externally mounted encoder with a receiver-side loom. For connector versions match the mating connector, shield and cable length and use the receiver drawing for the far end. A 12-pin cable wired for additional A\/B or sense can differ from the base SSI variant. \u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=1\"\u003eFactory cable order codes (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=#page=5\"\u003eVariant cable and connector maps (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate motion and supplies first.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check plug seating, foreign material, damaged pins, a loose coupling and a flexed or pinched cable. Verify that the machine actually turns the encoder shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the separate harness.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure the powered supply safely.\u003c\/strong\u003e With an approved breakout fitted while off, a qualified person can read DC from brown to white on the specified cable, or pins 2 to 1 on the documented base plug. Match 10–30 V versus 5 V to the encoder code. A valid supply alone leaves the CLOCK and DATA paths to check.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate link, setup and position.\u003c\/strong\u003e No clock at the encoder points toward the receiver or cable. Clock without a valid reply calls for power, wiring polarity and encoder checks. Smooth but wrongly scaled or jumping position calls for Gray\/binary, width, turn alignment, SET and DIR settings. Intermittency at high clock calls for inspecting the pairs, shield and receiver timing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eA documented example receiver is \u003cstrong\u003eBeckhoff EL5001\u003c\/strong\u003e, which has differential SSI clock\/data and a configurable word length up to 32 bits. Its clock ceiling is 1 MHz and its encoder supply is 24 V from the power contacts. Confirm code and bit framing, and choose a compatible clock within both limits. A 5 V version needs its specified 5 V supply. \u003ca href=\"https:\/\/infosys.beckhoff.com\/content\/1033\/el500x\/2206810635.html\"\u003eBeckhoff EL5001 SSI technical data\u003c\/a\u003e · \u003ca href=\"https:\/\/download.beckhoff.com\/download\/document\/io\/ethercat-terminals\/EL500x_en.pdf\"\u003eEL500x setup manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCommission the mechanical datum, count direction and SSI preset for the machine. Record the current value and receiver configuration before changing hardware. Check position through a full turn and across a turn boundary. Confirm home and permitted travel after any preset. This stand-alone encoder’s normal installation does not assign a motor commutation angle.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kuebler.com\/en\/pdf?5863-5883_en.pdf=\"\u003eKübler Sendix 5863 \/ 5883 data sheet (PDF)\u003c\/a\u003e. Pages 1, 3–6 for exact order codes, SSI specifications, SET and DIR, connector mapping and solid-shaft dimensions.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/download.beckhoff.com\/download\/document\/io\/ethercat-terminals\/EL500x_en.pdf\"\u003eBeckhoff EL500x SSI sensor interface manual (PDF)\u003c\/a\u003e. Use the EL5001 wiring and commissioning sections for this receiver example.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kuebler.com\/en\/products\/measurement\/encoders\/product-finder\/product-details\/5863\"\u003eKübler Sendix 5863 product page\u003c\/a\u003e. Configure the exact flange, shaft and interface before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51117014417573,"sku":"rtyu23","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/KublerSendix5863SSIMultiturnEncoderTechnicalGuideServiceVisitforInstallation_Repair_Alignment.jpg?v=1794123915","url":"https:\/\/www.sparefaber.com\/ar\/products\/kubler-sendix-5863-ssi","provider":"SpareFaber","version":"1.0","type":"link"}