{"product_id":"mitsubishi-obe102-hc-pq","title":"Mitsubishi Electric OBE102 HC-PQ Servo Feedback Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for OBE102 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Mitsubishi Electric OBE102 HC-PQ Servo Feedback Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eWe can isolate a harness or drive fault in the HC-PQ system before any work on the motor's built-in feedback assembly. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell documents the TI-5637 cable relationship. Confirm the exact OBE102 test profile, module, supply and pinout with Mitchell before a TI-5000JX test. Obtain separate TI-3000JX motor run confirmation. Use the MR-C manufacturer's diagnostic procedure for the fitted drive.\u003c\/p\u003e\n\u003ch2\u003eMitsubishi Electric OBE102 HC-PQ Servo Feedback Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eOBE102\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOBE102\u003c\/th\u003e\n\u003ctd\u003eMitchell lists this device with HC-PQ and a 20-pin Honda test connection. Verify the label and motor build.\u003c\/td\u003e\n\u003ctd\u003eHC-PQ feedback with TI-5637 test lead. Obtain the exact electrical specification for the fitted unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOSA18 \/ 191247\u003c\/th\u003e\n\u003ctd\u003eSeparate Mitsubishi encoder used on applicable HF-SP builds.\u003c\/td\u003e\n\u003ctd\u003eDifferent encoder and connection. Identify by full motor order and PCB label.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eMitsubishi identifies the MR-C\/HC-PQ platform as legacy and documents migration options. Confirm OBE102's exact service availability separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for OBE102\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for OBE102\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact device designation\u003c\/th\u003e\n\u003ctd\u003eOBE102 in Mitchell's HC-PQ cable listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest connection\u003c\/th\u003e\n\u003ctd\u003eTI-5637, 20-pin Honda\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM motor platform\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric HC-PQ with MR-C, per the OEM legacy and renewal records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExamples from OEM combination table\u003c\/th\u003e\n\u003ctd\u003eHC-PQ033(B), HC-PQ053(B), HC-PQ13(B), HC-PQ23(B) and HC-PQ43(B). The encoder suffix still needs verification for the exact motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOBE102 detail still needed\u003c\/th\u003e\n\u003ctd\u003eSerial format, supply limits, PCB pin map, encoder geometry and internal loom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/us.mitsubishielectric.com\/fa\/en\/support\/technical-support\/knowledge-base\/getdocument\/?docid=3E26SJWH3ZZR-38-1513\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe service starting point is the fitted motor and its built-in feedback assembly. Photograph the rear cover, encoder support, shaft retention and wiring before disassembly. On an isolated motor, inspect for rubbing, trapped wires or movement of the retention. Obtain the exact OBE102 mechanical drawing and motor procedure before adjusting the assembly.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe motor feedback reaches the MR-C system through its encoder lead. Confirm the serial signal format and differential connection on the motor drawing and drive interface before interpreting a data fault. Mitsubishi’s other servo families use different serial connections. A matching connector alone is insufficient to set the tester.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe Mitchell catalogue identifies a 20-pin Honda plug for the HC-PQ \/ OBE102 test setup. Read the correct cavity numbers and view from the TI-5637 sheet and Mitsubishi motor drawing. Determine the operating supply, return, data and shield paths before any live checks. Keep the encoder PCB, motor harness and amplifier connector maps separate.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eUse the exact HC-PQ order, including brake, shaft or gearbox suffixes, to identify the in-motor lead and cable to the amplifier. TI-5637 is the Mitchell fixture. Mitsubishi's MR-C renewal table separately identifies cable changes for motor and amplifier upgrades.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder alarm after cable or amplifier replacement\u003c\/th\u003e\n\u003ctd\u003eCompare the original and replacement motor\/drive combination, cable and connector key against the Mitsubishi table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent alarm when cable moves\u003c\/th\u003e\n\u003ctd\u003eInspect the Honda contacts, latch and strain relief. Check the isolated harness conductors and specified shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback is present but position changes after motor repair\u003c\/th\u003e\n\u003ctd\u003eCompare the rotor-to-encoder seating and original reference before commissioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo response at the controller\u003c\/th\u003e\n\u003ctd\u003eVerify the exact Mitsubishi serial option and the documented loaded supply at both ends before replacing the device.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMitsubishi lists HC-PQ as an MR-C motor platform. Mitchell cross-references OBE102 for HC-PQ. The OEM list names the compatible motor and amplifier combinations. Use the fitted label to determine which OBE102 revision is present. For the separate HF-SP family, see the \u003ca href=\"\/ar\/products\/mitsubishi-osa18-hf-sp\"\u003eOSA18 guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003ePreserve the encoder's installed orientation and the drive settings. The motor OEM must supply the procedure for rotor reference, initial offset and any stored settings. Match the motor and encoder before moving the feedback assembly or restoring data.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/us.mitsubishielectric.com\/fa\/en\/support\/technical-support\/knowledge-base\/getdocument\/?docid=3E26SJWH3ZZR-38-1513\"\u003eMain technical PDF\u003c\/a\u003e. Mitsubishi MR-C renewal table. Lists the supported motor and amplifier combinations and migration scope. Obtain a separate OBE102 encoder drawing for fit and pinout.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/us.mitsubishielectric.com\/fa\/en\/support\/parts\/legacy-products\/ac-servos\/mr-c\/\"\u003eManufacturer reference\u003c\/a\u003e. Mitsubishi's MR-C legacy product record names the HC-PQ and HC-KQ motor families.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell manufacturer cable index\u003c\/a\u003e. HC-PQ and OBE102 with the TI-5637 fixture.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4404782857755-Mitsubishi-Serial-Connections-4-wire-or-2-wire-data\"\u003eMitchell Mitsubishi serial connection note\u003c\/a\u003e. Connection families differ. Use the exact OBE102 drawing for service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51124704051365,"sku":"TCG124","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/mitsubishi-obe102-hc-pq-service-guide.jpg?v=1794210440","url":"https:\/\/www.sparefaber.com\/ar\/products\/mitsubishi-obe102-hc-pq","provider":"SpareFaber","version":"1.0","type":"link"}