{"product_id":"motor-power-t180-35-17-r1-feedback-technical-guide","title":"Motor Power T180 35 17 \/ R1 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eMotor Power T180 35 17 \/ R1 — Two-pole resolver. This technical service guide helps identify the fitted feedback and prepare a scoped installation, repair or alignment assessment. SpareFaber accepts UAE site-service enquiries and send-in bench evaluation requests after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eOEM documents\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted motor and feedback\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eT180 35 17 \/ R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder-number scope\u003c\/th\u003e\n\u003ctd\u003eScoped TETRA 180 model and feedback option. Brake, shaft, connection, rotor-inertia option and remaining order details require the complete fitted specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback interface\u003c\/th\u003e\n\u003ctd\u003eTwo-pole resolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eService scope\u003c\/th\u003e\n\u003ctd\u003eMotor feedback assessment; this listing is not an offer of a stocked replacement motor or encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePhotograph the complete motor label, encoder label, connectors and mounting arrangement. Record the drive model and actual alarm text. The guide describes a selected configuration; the received assembly must still match it, especially after an earlier repair.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: confirm the connection first\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX scope\u003c\/th\u003e\n\u003ctd\u003eEvaluate resolver angle, sine\/cosine balance and direction with a compatible excitation and supported resolver setup. This analogue R selection does not provide a serial encoder identity, memory clone or retained multiturn count.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable \/ fixture boundary\u003c\/th\u003e\n\u003ctd\u003eConfirm excitation frequency, voltage units, transformation ratio, resolver speed and the actual connector. The TI-5000JX built-in excitation is specified up to 8 V peak; this must not be treated as 8 V RMS or assumed to meet a 7 V RMS catalogue condition. Document the actual excitation and any test limitation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX run scope\u003c\/th\u003e\n\u003ctd\u003eUse the matching generic resolver run setup with the actual winding, six-pole motor data, direction and verified alignment. A motor-run assessment depends on the exact supported selection, successful prior feedback checks, winding data, power fixture and tester current\/voltage limits. Catalogue power, frame size or speed does not establish that the whole motor can be run at full speed or full load on a particular bench.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eConfirm the installed software selection, fitted feedback and fixture before applying power. Family support establishes a route for evaluation; acceptance of the received winding, connector and encoder combination follows inspection. Record what the test actually covered and any excluded functions.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe linked manufacturer document identifies this catalogue configuration. Current production, availability and any approved successor require confirmation against the complete fitted order. A downloadable manual does not prove present stock. Compare voltage, winding, mounting, shaft, brake, feedback, connector and stored motor-data requirements before accepting a replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSelected motor \/ feedback\u003c\/th\u003e\n\u003ctd\u003eT180 35 17 \/ R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback interface\u003c\/th\u003e\n\u003ctd\u003eTwo-pole resolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor voltage \/ poles\u003c\/th\u003e\n\u003ctd\u003e400 VAC \/ 6 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eContinuous stall torque\u003c\/th\u003e\n\u003ctd\u003e39 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal torque \/ power\u003c\/th\u003e\n\u003ctd\u003e21 Nm \/ 6.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal speed\u003c\/th\u003e\n\u003ctd\u003e3000 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMass without holding brake\u003c\/th\u003e\n\u003ctd\u003e36 kg; verify feedback and option allowances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRating condition\u003c\/th\u003e\n\u003ctd\u003eSpecified metallic heat-sink flange coupling; oil-seal derating applies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback option\u003c\/th\u003e\n\u003ctd\u003eR1 — two-pole resolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM evidence\u003c\/th\u003e\n\u003ctd\u003eTETRA 180 ratings PDF 37; dimensions PDF 38; feedback PDF 40; connections PDF 44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder-number scope\u003c\/th\u003e\n\u003ctd\u003eScoped TETRA 180 model and feedback option. Brake, shaft, connection, rotor-inertia option and remaining order details require the complete fitted specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe A1 and R1 codes identify distinct feedback systems. The A1 analogue period count, serial singleturn resolution and revolution range are separate quantities. R1 is a one-speed resolver; its two poles are separate from the motor’s six poles.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eUse the T180 drawing for T180 35 17 and its selected brake, shaft and inertia arrangement. The catalogue rates this motor with a 500 × 500 × 30 mm metallic heat-sink flange coupling; oil-seal fitting requires derating. Confirm lifting and support from the actual assembled mass.\u003c\/p\u003e\n\u003cp\u003eRecord the shaft datum, coupling position, pilot fit and feedback retention before disassembly. Inspect bearing play, shaft damage, contamination and moisture. Motor flange and shaft dimensions do not define the encoder coupling or its tightening torque. Use the actual assembly drawing for fasteners, retention and sealing, and record any previous modifications.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eMatch the A1 or R1 feedback drawing to the actual connector and contact view. A1 uses the documented HIPERFACE supply\/data and analogue paths; R1 uses excitation and resolver outputs. Do not transfer pin assignments between those options.\u003c\/p\u003e\n\u003cp\u003eSeparate motor power, protective earth, low-voltage feedback and temperature circuits. Verify contact numbering, gender, keying and mating-face versus wire-side view. A connector that mates mechanically does not prove electrical compatibility. Verify the sensor supply from its own documentation; the motor voltage class is a different quantity.\u003c\/p\u003e\n\u003cp\u003eBrake presence, brake supply and shaft structure are determined by the remaining order suffixes. Confirm the actual brake label and release condition before movement. Feedback testing does not certify holding torque or the machine holding arrangement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the internal encoder-to-motor loom separately from the external machine cable and bench fixture. The internal loom part number is not established by the frame or interface alone. Obtain both connector faces, the assembly diagram and the correct contact view. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation. A Mitchell test lead identifies a test connection; it is not an OEM replacement machine cable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks and useful observations\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo feedback communication\u003c\/th\u003e\n\u003ctd\u003eConfirm the exact interface, fixture, supply and contact orientation. Check the selected connection boundary before concluding that the sensor is defective.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition jumps or intermittent alarms\u003c\/th\u003e\n\u003ctd\u003eRecord direction, movement range, cable position and temperature. Compare a stationary cable check with controlled movement where the supported setup permits it.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault after encoder or bearing work\u003c\/th\u003e\n\u003ctd\u003eCompare the incoming memory\/reference record, fitted sensor identity, mechanical retention and phase relationship. A stable position display does not establish correct commutation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBench result differs from the machine\u003c\/th\u003e\n\u003ctd\u003eCheck which loom, connector, drive interface and operating conditions the bench bypassed. Reproduce the actual symptom before recommending a component change.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor motion or holding issue\u003c\/th\u003e\n\u003ctd\u003eBrake presence, brake supply and shaft structure are determined by the remaining order suffixes. Confirm the actual brake label and release condition before movement. Feedback testing does not certify holding torque or the machine holding arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eKeep each observation separate from the conclusion. State whether a fault is repeatable, which connection was tested and what changed after cleaning or adjustment. Avoid replacing an encoder solely because the drive reports a feedback alarm; a damaged cable, incorrect parameter or mechanical problem can produce a similar report.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and stored data\u003c\/h2\u003e\n\u003cp\u003eRecord the resolver-to-motor relationship before removal. Confirm motor pole count, one-speed resolver behaviour, direction and the correct OEM alignment procedure. A two-pole resolver is not a statement that the motor itself has two poles. Machine home and motor commutation are separate; there is no serial memory to clone in this resolver option.\u003c\/p\u003e\n\u003cp\u003eAn alignment operation concerns the motor\/feedback relationship; machine home, travel limits and process offsets remain separate. Preserve original records, use the fitted procedure and document the measured result after reassembly.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor, drive and replacement matching\u003c\/h2\u003e\n\u003cp\u003eMatch the complete chain: full motor order, feedback option, internal loom, external cable and drive configuration. Similar frame size, wattage or interface wording does not establish interchangeability. Confirm shaft and flange fit, brake requirements, thermal sensing, winding and stored-data requirements before approving a substitute.\u003c\/p\u003e\n\u003cp\u003eUse the matching generic resolver run setup with the actual winding, six-pole motor data, direction and verified alignment. A motor-run assessment depends on the exact supported selection, successful prior feedback checks, winding data, power fixture and tester current\/voltage limits. Catalogue power, frame size or speed does not establish that the whole motor can be run at full speed or full load on a particular bench.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and supporting evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26578514023963-Generic-Resolvers\" target=\"_blank\" rel=\"noopener\"\u003eFeedback support and connection reference\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26594756325275-Generic-Resolvers\" target=\"_blank\" rel=\"noopener\"\u003eFeedback support and connection reference\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.motorpowerco.com\/media\/l1sdzdob\/tetra_tetra_compact_34_10_2022_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOEM motor documentation — TETRA 180 ratings PDF 37; dimensions PDF 38; feedback PDF 40; connections PDF 44\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource review: 21 November 2026. Dimensions and model codes refer to the cited catalogue scope. Confirm the document revision and complete fitted nameplate before extending wiring, replacement or motor-run claims. A catalogue or test-support entry does not establish current stock or a repair outcome.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon service questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIs this a complete replacement order number?\u003c\/summary\u003e\u003cp\u003eScoped TETRA 180 model and feedback option. Brake, shaft, connection, rotor-inertia option and remaining order details require the complete fitted specification.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a good position reading clear the whole axis?\u003c\/summary\u003e\u003cp\u003eNo. Feedback, motor power, drive behaviour, machine cable, holding arrangements and loaded performance are separate evaluation boundaries.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the original encoder be replaced by another with the same interface?\u003c\/summary\u003e\u003cp\u003eOnly after the mechanical fit, electrical connection, exact sensor\/profile, stored data and alignment requirements have been checked for this motor.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat should accompany a service enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear motor and feedback labels, connector photographs, drive model, alarm text and fault history. Describe recent repair work and whether the problem appears at startup, during motion or after warming up.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"assessment-record\"\u003e\u003ch2\u003eWhat the service record should contain\u003c\/h2\u003e\n\u003cp\u003eRecord the received model, serial or service ID, fitted feedback, mechanical condition and original fault before work begins. Include the test profile, connection boundary, fixture and supply\/excitation used. Preserve readable original memory or parameter reports where relevant. Record evidence before and after each adjustment so an intermittent condition is not reported as a confirmed cure without a repeatable check.\u003c\/p\u003e\n\u003cp\u003eThe assessment should distinguish a confirmed defect, a proposed repair and any unresolved condition. State tests that need the machine, a missing drawing or a different fixture. Replacement availability, service timing and the final repair scope are confirmed after inspection.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51266284159141,"sku":"TCG1224","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/tcg1224-service-guide.png?v=1795269222","url":"https:\/\/www.sparefaber.com\/ar\/products\/motor-power-t180-35-17-r1-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}