{"product_id":"mts-custom-servo-mpm-unico-319-663-ssi-feedback-technical-guide","title":"MTS \/ Custom Servo MPM \/ Unico 319-663 SSI SSI absolute | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eMTS \/ Custom Servo MPM \/ Unico 319-663 SSI — SSI absolute. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eMTS \/ Custom Servo MPM \/ Unico 319-663 SSI — Motor application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eUnico 319-663\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer MPN \/ full suffix\u003c\/th\u003e\n\u003ctd\u003eMPM \/ Unico 319-663 SSI is the scoped family\/designation. Match every additional character on the fitted label before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM service ID \/ motor order\u003c\/th\u003e\n\u003ctd\u003eNot established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eSSI absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented starting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5636 drawing, reversed 12-contact M23 orientation. Mitchell says a ready cable is not currently offered; verify connector view and 10–30 V external supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial distinction\u003c\/th\u003e\n\u003ctd\u003eTCG362 is MPM resolver\/tach; TCG388 is incremental. TCG119 is the standalone Unico device.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eConditional bench scope: Identify MPM’s Unico SSI option and verify code format and clock\/data connections. Exact fixture, supply and drawing must agree before connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5636 drawing, reversed 12-contact M23 orientation. Mitchell says a ready cable is not currently offered; verify connector view and 10–30 V external supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eMatch exact profile, supply, connector and installed software. A named cable is not a complete test procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eBench serial count\/data scope. Mitchell supplies no Unico motor direction or alignment data; exact MPM motor-run setup remains open.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe admission evidence is Mitchell Test Cable Index by Manufacturer Support — PDF pages 4,9,15, TI-5636. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eCurrent production status, exact-order stock and an approved successor have not been confirmed in the cited evidence. Retain the installed label and ask for an exact-order check before selecting a replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSSI word\u003c\/th\u003e\n\u003ctd\u003e12 position bits + 12 revolution bits in a 24-bit Gray word, followed by an alarm bit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply and signaling\u003c\/th\u003e\n\u003ctd\u003e10–30 V external encoder supply; 5 V serial signal levels. Use the original diagram for the shared 0 V reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCounts and retention\u003c\/th\u003e\n\u003ctd\u003e4,096 positions per revolution and 4,096 revolutions; the documented device does not use battery backup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ output compatibility\u003c\/th\u003e\n\u003ctd\u003eUse the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact dimensions, torque and pins\u003c\/th\u003e\n\u003ctd\u003eUse the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eSSI shifts a clocked absolute data word. This Unico example uses a 24-bit Gray word comprising 12 position bits and 12 revolution bits, followed by an alarm bit. Power supply and serial signal levels are different: the cited external supply is 10–30 V while data\/clock use 5 V levels. Follow the original diagram and common-reference arrangement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003ePhotograph the incoming shaft\/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model.\u003c\/p\u003e\n\u003cp\u003eMPM is named in the cable index with Unico SSI and TI-5636. Mitchell’s Unico article describes a reversed-orientation 12-contact connection and says a ready cable is not currently offered. Its 10–30 V encoder supply is external; the serial signals remain 5 V levels. No Unico motor direction\/alignment data are provided.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eMap five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive\/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5636 drawing, reversed 12-contact M23 orientation. Mitchell says a ready cable is not currently offered; verify connector view and 10–30 V external supply.. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eTI-5636 identifies the documented test connection, not an OEM internal loom. Mitchell describes reversed contact orientation compared with the similar Indramat-style connector and says a ready cable is not currently offered. Obtain the MPM internal assembly and external machine-cable drawings before sourcing a loom or building a matched fixture.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration-specific check\u003c\/th\u003e\n\u003ctd\u003eMPM is named in the cable index with Unico SSI and TI-5636. Mitchell’s Unico article describes a reversed-orientation 12-contact connection and says a ready cable is not currently offered. Its 10–30 V encoder supply is external; the serial signals remain 5 V levels. No Unico motor direction\/alignment data are provided.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault appears when the machine cable moves\u003c\/th\u003e\n\u003ctd\u003eWith the system isolated and both ends disconnected, inspect flex points, connector engagement and repaired sections. Check end-to-end continuity and unintended shorts against the actual pin map, accounting for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo feedback or intermittent loss at the drive\u003c\/th\u003e\n\u003ctd\u003eAfter label and fixture verification, have a qualified technician check the specified supply or excitation through an approved breakout. Compare at the source and load under the OEM procedure; never assume a voltage from the connector shell.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition reads but status or retained reference is wrong\u003c\/th\u003e\n\u003ctd\u003eSave detected identity, status and incoming position. Check the documented profile and retention arrangement before a reset, battery intervention or data transfer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003ePreserve machine zero, direction and the incoming SSI position before removal. Mitchell explicitly states that it has no Unico motor alignment or forward armature information. A serial count pass cannot supply the missing MPM phase relationship or a complete motor-run procedure.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMPM \/ Unico 319-663 SSI. \u003ca href=\"https:\/\/www.sparefaber.com\/products\/mts-custom-servo-mpm-resolver-tachometer-feedback\"\u003eTCG362\u003c\/a\u003e is MPM resolver\/tach; \u003ca href=\"https:\/\/www.sparefaber.com\/products\/control-techniques-custom-servo-mpm-incremental-feedback-technical-guide\"\u003eTCG388\u003c\/a\u003e is incremental. \u003ca href=\"https:\/\/www.sparefaber.com\/products\/unico-319-663-ssi\"\u003eTCG119\u003c\/a\u003e is the standalone Unico device.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMitchell Test Cable Index by Manufacturer Support\u003c\/a\u003e — PDF pages 4,9,15, TI-5636\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26657551576603-Unico-SSI-Serial-Encoders\" target=\"_blank\" rel=\"noopener\"\u003eUnico SSI Serial Encoders\u003c\/a\u003e — Named model, option or connection; see the proposal locator. Bench evidence and motor-run scope remain separate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExact OEM technical PDF remains to obtain. The Mitchell reference establishes only the documented device or motor\/feedback connection; it does not fill missing ratings or pins.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a MPM \/ Unico 319-663 SSI enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eBench serial count\/data scope. Mitchell supplies no Unico motor direction or alignment data; exact MPM motor-run setup remains open. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51144084816037,"sku":"TCG508","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/mts-custom-servo-mpm-unico-319-663-ssi-service-guide.jpg?v=1794326847","url":"https:\/\/www.sparefaber.com\/ar\/products\/mts-custom-servo-mpm-unico-319-663-ssi-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}