{"product_id":"parker-nx310e-r-sks36-feedback-technical-guide","title":"Parker NX310E \/ R SKS36 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eParker NX310E \/ R\u003c\/strong\u003e uses the documented SKS36 singleturn classic HIPERFACE option. This guide helps identify the fitted feedback, distinguish an encoder fault from a cable or setup issue, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting scope\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted configuration\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ motor base\u003c\/td\u003e\n\u003ctd\u003eParker NX310E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelected OEM feedback option\u003c\/td\u003e\n\u003ctd\u003eR — SKS36, singleturn classic HIPERFACE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentifier scope\u003c\/td\u003e\n\u003ctd\u003eMotor base plus feedback selection; not a complete motor order. Confirm every fitted suffix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParker feedback part number\u003c\/td\u003e\n\u003ctd\u003e220174P0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraked representative\u003c\/td\u003e\n\u003ctd\u003e4 — brake + PTC on power connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService reference\u003c\/td\u003e\n\u003ctd\u003eTCG1525 — SpareFaber reference, not an OEM part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eConfirm the complete motor order, encoder suffix\/serial, drive model and connector revision. The catalogue connects this base and option to the named feedback family; an exact Mitchell entry for this motor was not found in the reviewed material. That does not prevent scoped testing of the positively identified feedback.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX: identified SKS36 \/ SKM36 classic HIPERFACE feedback. Evaluate serial position and analogue signals; retain incoming alignment\/memory.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting connection:\u003c\/strong\u003e TI-5094 direct to verified SKS\/SKM encoder plug; TI-5104 after label\/supply check. Motor-bulkhead adapter is not established by this proposal.\u003c\/p\u003e\n\u003cp\u003eMatch the actual encoder selection and lead in the installed Athena software. Check identity\/status and serial position, then evaluate the analogue path separately. A clean position count alone does not prove correct analogue amplitude or installed commutation alignment. Record the equipment, cable, software version and fitted encoder label with the result; no minimum firmware version is asserted for this exact assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor-run scope:\u003c\/strong\u003e Unestablished for this exact motor. Confirm motor parameters, fixture, phase order, brake, alignment and installed TI-3000JX profile before run testing.\u003c\/p\u003e\n\u003cp\u003eThe MOOG reference is used only because it documents the identified encoder families and their direct connectors. It does not authorize a MOOG motor profile, machine cable or alignment value for this application.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSignals and specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented value \/ boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor base\u003c\/td\u003e\n\u003ctd\u003eParker NX310E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelected feedback\u003c\/td\u003e\n\u003ctd\u003eR — SKS36, singleturn classic HIPERFACE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eSerial RS-485 absolute position plus analogue sine\/cosine paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial position per revolution\u003c\/td\u003e\n\u003ctd\u003e4,096 positions (12 bits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue periods per revolution\u003c\/td\u003e\n\u003ctd\u003e128 sine\/cosine periods; not drive-scaled counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-revolution information\u003c\/td\u003e\n\u003ctd\u003eSingleturn; no retained multi-revolution count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback supply\u003c\/td\u003e\n\u003ctd\u003e7–12 V DC in the scoped OEM table; verify the fitted encoder label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake selection\u003c\/td\u003e\n\u003ctd\u003e4 — holding brake with PTC on power connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue stall torque\u003c\/td\u003e\n\u003ctd\u003e2 Nm at the catalogue conditions; not continuous torque at every speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParker feedback part number\u003c\/td\u003e\n\u003ctd\u003e220174P0003 — encoder reference, not a complete motor MPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor poles\u003c\/td\u003e\n\u003ctd\u003e10 poles (5 pole pairs), NX series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding brake\u003c\/td\u003e\n\u003ctd\u003e24 V DC; 2 Nm \/ 11 W for NX3 at the catalogue conditions; p.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue feedback speed limit\u003c\/td\u003e\n\u003ctd\u003e12,000 min⁻¹ for SKS36; not an allowed motor run speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor winding \/ rated speed\u003c\/td\u003e\n\u003ctd\u003eNot selected by this motor-base guide; verify the complete motor order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eAnalogue periods, serial positions, multi-revolution range and drive-scaled counts are different quantities. A catalogue period count is not an assumed controller resolution. Feedback supply, motor DC-link\/drive supply and brake supply are separate circuits.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNX310E\u003c\/strong\u003e is a natural-cooled NX motor base with 2 Nm catalogue stall torque. The selected feedback service reference is 220174P0003. Winding remains unspecified; a different winding alone does not define another feedback guide.\u003c\/p\u003e\n\u003cp\u003eThe p.9 dimensional table gives 71 mm motor dimension A, 60 mm flange centring \/ 75–80 mm hole interaxis and an 11 × 23 mm shaft. These are motor mounting dimensions, not encoder shaft dimensions. Confirm the complete shaft-end, brake and connector build before assessing a replacement.\u003c\/p\u003e\n\u003cp\u003eThe p.12 brake added-length table is explicitly labelled for resolver builds. Do not use that increment to certify the overall length of an R\/S HIPERFACE assembly. Match the full OEM drawing, and record the original encoder locating\/coupling arrangement and cable route before removal. This catalogue does not establish every internal loom, retention torque or fitted SICK suffix.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eUse the separate feedback-connector table for \u003cstrong\u003eletters R\/S\/T\/U\u003c\/strong\u003e on Parker p.14, after matching the actual connector drawing and contact view. R\/S are classic HIPERFACE according to the unambiguous order and encoder tables on pp.11 and 13.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eOEM motor feedback contact\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSignal \/ scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003ctd\u003eSin+ \/ Ref Sin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 \/ 4\u003c\/td\u003e\n\u003ctd\u003eCos+ \/ Ref Cos\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 \/ 6\u003c\/td\u003e\n\u003ctd\u003eThermal contacts only when that feedback-connector option is fitted; option 4 puts PTC on power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 \/ 10\u003c\/td\u003e\n\u003ctd\u003eData+ \/ Data−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eUs supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe p.14 caption labels that R\/S\/T\/U table “Hiperface DSL”, which conflicts with the R\/S definitions on pp.11\/13. Do not use the caption alone: the table has separate Sin\/Cos and Data pairs, whereas P\/Q DSL uses the separate power-connector arrangement. For option 4, the PTC is on the power connection. Obtain the fitted drawing if any label or pin layout differs.\u003c\/p\u003e\n\u003cp\u003eUse the original drawing to confirm contact view, keying and revision before wiring. No pin assignment here is a terminal-block map for the Mitchell tester.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eInternal, machine and test cables\u003c\/h2\u003e\n\u003cp\u003eTI-5094 direct to verified SKS\/SKM encoder plug; TI-5104 after label\/supply check. Motor-bulkhead adapter is not established by this proposal.\u003c\/p\u003e\n\u003cp\u003eThe direct-to-encoder lead is an internal bench connection. The motor bulkhead connector, machine extension and drive-end connector form separate interfaces. No verified internal loom or complete machine-cable part number is established for this exact full order. Record both-end connector photos, cable markings, routing and required length before selecting a replacement harness.\u003c\/p\u003e\n\u003cp\u003eCheck the manufacturer drawing and current Mitchell lead sheet together before adapting a connection. A compatible communication protocol does not make a physical plug or pinout interchangeable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cp\u003eBefore physical checks, secure the driven load, isolate and lock out relevant energy sources, observe the specified discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short checks and account for intentional shield bonds. Powered measurement, rotation, brake release and alignment require the applicable specialist procedure.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eUseful next check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo serial position or incorrect encoder identity\u003c\/td\u003e\n\u003ctd\u003eVerify the fitted model and software choice, approved supply and serial pair, then inspect connector seating and cable condition. Separate cable and encoder tests before replacing the sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial position reads but analogue path is weak or noisy\u003c\/td\u003e\n\u003ctd\u003eConfirm the correct sine\/cosine pairs and source amplitude using the approved signal test. Inspect shielding, contamination and cable damage; an incrementing serial count does not clear the analogue channels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition or direction changes after refitting\u003c\/td\u003e\n\u003ctd\u003eCompare full feedback option, drive scaling\/direction, preserved offset and mechanical reference. Do not copy an offset from a similar motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault follows cable movement\u003c\/td\u003e\n\u003ctd\u003eWith the installation isolated, inspect strain relief, pin retention, moisture and both-end cable continuity against the actual wiring drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor will not turn or reports a run fault\u003c\/td\u003e\n\u003ctd\u003eCheck load\/brake condition and the separately approved motor-run setup. A feedback pass does not prove correct brake release, winding connection or phase order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eIncoming alignment, offsets and memory\u003c\/h2\u003e\n\u003cp\u003eBefore loosening, removing, resetting or programming the feedback, record the incoming mechanical reference, supported commutation\/alignment reading, motor pole count, direction and phase convention. Preserve drive offsets and parameters with readable encoder identity, memory\/status and offset data. Tie the record to the motor and encoder serials and the test setup.\u003c\/p\u003e\n\u003cp\u003eRetain or reproduce a \u003cstrong\u003evalid incoming alignment\u003c\/strong\u003e under the applicable specialist method, then verify it after refitting. Memory retention alone does not prove physical alignment. Where motor-specific memory decoding is unavailable, keep readable data without labelling a raw backup as a verified alignment value.\u003c\/p\u003e\n\u003cp\u003eIf the feedback was already disturbed, the reference is invalid, or memory is absent\/corrupt\/unreadable, record that limitation and obtain the motor-specific recovery method. No universal angle, automatic recovery, or default transfer from another motor is established here. Confirm hardware, data format and the complete motor order before any memory write.\u003c\/p\u003e\n\u003cp\u003eFor this singleturn SKS36 branch, the encoder identifies position within one revolution; machine-level multi-revolution referencing is a separate control function.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eParker catalogue 192-063002, October 2024, documents this NX R\/S configuration and the encoder part references. It does not establish current stock, exact full-order production status or a drop-in successor. Obtain a current supplier check for the complete motor order, encoder suffix and hardware revision.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor applications and related guides\u003c\/h2\u003e\n\u003cp\u003eR is SKS36 singleturn, Parker 220174P0003; S is SKM36 multiturn, Parker 220174P0004. Both use 128 sine\/cosine periods and 4,096 serial positions per revolution. S adds a 4,096-turn range. P\/Q are EKS36\/EKM36 HIPERFACE DSL and require a different connection and test scope. The SICK suffix of a generic SKS36 guide is not automatically the Parker-fitted suffix.\u003c\/p\u003e\n\u003cp\u003eRelated pages below provide additional identification context. A related guide is not a replacement or compatibility approval for this complete motor order.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sparefaber.com\/products\/sick-sks36-hfa0-k02-1034095\" target=\"_blank\" rel=\"noopener\"\u003eSICK SKS36-HFA0-K02 1034095 HIPERFACE Single-Turn Encoder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sparefaber.com\/products\/parker-hdy-hiperface-feedback-technical-guide\" target=\"_blank\" rel=\"noopener\"\u003eParker HDY HIPERFACE Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings and primary documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Electromechanical-Europe\/Literature\/192_063002_NX_Series_Catalogue.pdf\" target=\"_blank\" rel=\"noopener\"\u003eParker NX Series catalogue 192-063002, October 2024\u003c\/a\u003e — P1 pp.6–7 (base rows), p.9 (motor outline), p.11 (R\/S feedback and brake 4 order codes), p.12 (holding-brake data), p.13 (SKS36\/SKM36 device and Parker IDs), p.14 (feedback connector; caption conflict retained in wiring section).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26697502947227-SICK-Stegmann-Hiperface-Serial-Encoders\" target=\"_blank\" rel=\"noopener\"\u003eMitchell: SICK Stegmann HIPERFACE Serial Encoders\u003c\/a\u003e — Device testing, connection, commutation, memory\/status and analogue signal assessment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/48944747309339-MOOG-Motors\" target=\"_blank\" rel=\"noopener\"\u003eMitchell: MOOG Motors\u003c\/a\u003e — Stegmann Absolute Encoders section; direct-to-encoder leads only, not a motor-specific adapter or alignment approval.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExact application evidence:\u003c\/strong\u003e P1 pp.6–7 (base rows), p.9 (motor outline), p.11 (R\/S feedback and brake 4 order codes), p.12 (holding-brake data), p.13 (SKS36\/SKM36 device and Parker IDs), p.14 (feedback connector; caption conflict retained in wiring section).\u003c\/p\u003e\n\u003cp\u003eSource scope reviewed 23 November 2026. Match the document revision, complete fitted labels and actual connector before using a drawing, replacement or test connection.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFAQ and service enquiry\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan this feedback be evaluated without an exact Mitchell motor entry?\u003c\/summary\u003e\u003cp\u003eYes, once the fitted device, supply and connection are positively identified within the documented feedback scope. Evaluate serial position and analogue signals and preserve valid incoming alignment\/memory. Motor-run approval remains a separate setup decision.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan I replace this option with the paired singleturn\/multiturn version?\u003c\/summary\u003e\u003cp\u003eR is SKS36 singleturn, Parker 220174P0003; S is SKM36 multiturn, Parker 220174P0004. Both use 128 sine\/cosine periods and 4,096 serial positions per revolution. S adds a 4,096-turn range. P\/Q are EKS36\/EKM36 HIPERFACE DSL and require a different connection and test scope. The SICK suffix of a generic SKS36 guide is not automatically the Parker-fitted suffix. Verify drive support, mounting, wiring, exact suffix and motor data before considering substitution.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information should accompany a service enquiry?\u003c\/summary\u003e\u003cp\u003eSend the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and service history. Include the cable labels and any saved incoming alignment\/data record. SpareFaber can then scope a UAE site investigation or send-in evaluation.\u003c\/p\u003e\u003c\/details\u003e\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or send-in evaluation\u003c\/a\u003e. Scope, parts and turnaround are confirmed after reviewing the fitted configuration and fault.\u003c\/p\u003e\u003c\/section\u003e","brand":"Parker","offers":[{"title":"Default Title","offer_id":51290482933925,"sku":"TCG1525","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/parker-nx310e-r-sks36-feedback-technical-guide-service-card.png?v=1795407651","url":"https:\/\/www.sparefaber.com\/ar\/products\/parker-nx310e-r-sks36-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}