{"product_id":"posital-ixarc-ucd-ca01b-canopen","title":"POSITAL IXARC UCD-CA01B-1312-HATS-2AW CANopen Encoder  | Technical Guide| Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eCANopen node offline or returning the wrong position?\u003c\/strong\u003e SpareFaber can visit your UAE site to check the IXARC mount, supply, bus wiring, node setup and position. Ask about bench communication and turn-count checks for the exact part.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"POSITAL IXARC UCD-CA01B-1312-HATS-2AW CANopen Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full encoder order code, controller, node ID and bit rate, current symptoms, bus layout and installation photos. Capture any existing presets and resolution settings before replacing the encoder. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA compatible CANopen master can check boot-up, heartbeat, error messages and position PDOs. A qualified technician can compare bus waveforms, supply voltage under load and repeatable position over multiple turns. Test a spare on an isolated service bus with the appropriate configuration before reconnecting it to production. Exact Mitchell TI-5000JX and TI-3000JX support was not verified for this CANopen encoder. \u003ca href=\"https:\/\/www.posital.com\/media\/posital_fsimg\/manual-ixarc-ucd-ca.pdf\"\u003ePOSITAL CANopen commissioning and diagnostics (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003ePOSITAL IXARC UCD-CA01B-1312-HATS-2AW CANopen Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead \u003cstrong\u003eUCD-CA01B-1312-HATS-2AW\u003c\/strong\u003e and product number \u003cstrong\u003e1618782\u003c\/strong\u003e. In this build, the 1312 field corresponds to 13 multiturn and 12 singleturn bits. Match the complete housing and termination fields before ordering or applying a wire map.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Exact IXARC CANopen examples\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eExact IXARC CANopen examples\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eOrder code \/ item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePosition and mounting\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eConnection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUCD-CA01B-1312-HATS-2AW · 1618782\u003c\/th\u003e\n\u003ctd\u003e13 MT + 12 ST, Ø10 mm blind bore, Ø58 mm body\u003c\/td\u003e\n\u003ctd\u003eAxial 2 m factory PVC flying lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUCD-CA01B-1312-HBS0-PRR · 1645162\u003c\/th\u003e\n\u003ctd\u003e13 MT + 12 ST. Read the separate HBS0 shaft dimensions.\u003c\/td\u003e\n\u003ctd\u003eM23 12-pin connection, separate pin map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUCD-CA01B-0016-H8PS-PRV · 1770216\u003c\/th\u003e\n\u003ctd\u003eSingleturn, 16-bit, Ø8 mm blind bore\u003c\/td\u003e\n\u003ctd\u003eM12 build, separate pin map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HATS-2AW\/1618782\"\u003e1618782 exact catalogue\u003c\/a\u003e · \u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HBS0-PRR\/1645162\"\u003e1645162 exact catalogue\u003c\/a\u003e · \u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-0016-H8PS-PRV\/1770216\"\u003e1770216 exact catalogue\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003ePOSITAL marks exact product 1618782 \u003cstrong\u003eEstablished\u003c\/strong\u003e on its Product Life Cycle line. Confirm orderability and delivery for the full part code. Reviewed 7 November 2026. \u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HATS-2AW\/1618782\"\u003ePOSITAL exact lifecycle record\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"POSITAL 1618782 exact data\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003ePOSITAL 1618782 exact data\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eMagnetic absolute. Self-powered multiturn pulse counter, no backup battery or gear.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition range\u003c\/th\u003e\n\u003ctd\u003e12 bits per turn (4096 positions), 13 multiturn bits (8192 turns), binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus\u003c\/th\u003e\n\u003ctd\u003eCANopen DS-406, 20 kbit\/s–1 Mbit\/s, galvanically isolated transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply and current\u003c\/th\u003e\n\u003ctd\u003e9–30 V DC. ≤70 mA at 10 V DC and ≤50 mA at 24 V DC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit and speed\u003c\/th\u003e\n\u003ctd\u003eØ58 mm body, Ø10 mm blind bore × 28 mm depth, ≤3000 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMisalignment\u003c\/th\u003e\n\u003ctd\u003eStatic axial ±0.3 mm and radial ±0.5 mm. Dynamic axial ±0.1 mm and radial ±0.2 mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment and lead\u003c\/th\u003e\n\u003ctd\u003eIP66\/IP67, fixed lead −30 to +80 °C and flexing lead −5 to +80 °C. 2 m PVC, 46 mm minimum bend radius fixed or 61 mm flexing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HATS-2AW\/1618782\"\u003eExact POSITAL technical data and drawings\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eSlide the encoder’s blind bore onto the measured shaft and use the specified clamping arrangement and housing restraint. Match the shaft insertion length and mounting geometry to the Drawings tab. The housing restraint keeps the encoder body fixed while allowing the intended movement within the static and dynamic misalignment limits. Check for a bottomed-out shaft or an overconstrained mounting before tightening. The drawing and machine installation instructions govern fasteners and torque. \u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HATS-2AW\/1618782\"\u003ePOSITAL exact drawing and accessories\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe encoder publishes a digital position on a shared CANopen bus. The controller can receive a process data object (PDO) by the configured trigger and use service data objects (SDOs) for approved parameters. The controller and encoder need a unique node ID, matching bit rate and compatible EDS\/configuration. A node can be visible and still report wrong travel if the scaling, direction, PDO mapping or preset differs.\u003c\/p\u003e\n\u003cp\u003eThe self-powered turn counter tracks rotation without a backup battery. Check machine reference separately from raw encoder position, especially after replacing or presetting an encoder. \u003ca href=\"https:\/\/www.posital.com\/en\/canopen-encoder\"\u003ePOSITAL CANopen overview\u003c\/a\u003e · \u003ca href=\"https:\/\/www.posital.com\/media\/posital_fsimg\/manual-ixarc-ucd-ca.pdf\"\u003eUCD CANopen user manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Exact 1618782 axial flying lead, POSITAL Connection Plan tab\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eExact 1618782 axial flying lead, POSITAL Connection Plan tab\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eLead colour\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRed\u003c\/th\u003e\n\u003ctd\u003eEncoder power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eYellow\u003c\/th\u003e\n\u003ctd\u003eSupply ground \/ return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWhite\u003c\/th\u003e\n\u003ctd\u003eCAN High\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrown\u003c\/th\u003e\n\u003ctd\u003eCAN Low\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGreen\u003c\/th\u003e\n\u003ctd\u003eCAN GND, bus reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eSupply ground and CAN GND are listed separately. The installed bus drawing determines bonding and any shield treatment. The wire colours above apply to the exact factory lead, not to a generic M12 pinout. Use the connection plan for the other connector codes. \u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HATS-2AW\/1618782\"\u003ePOSITAL 1618782 Connection Plan\u003c\/a\u003e · \u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HBS0-PRR\/1645162\"\u003eSeparate M23 variant connection plan\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThis external unit comes with a 2 m axial PVC lead, 0.14 mm² conductors. It has no in-motor PCB-to-bulkhead harness. Use the network drawing to terminate the lead to the correct CAN branch. The separate HATS-PAV connector versions use a different ordering code and cable accessory. Match any replacement to the label, installation sealing and wire map. \u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HATS-2AW\/1618782\"\u003ePOSITAL exact lead and accessories\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore disturbing the bus or shaft.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Preserve the network configuration and coordinate any isolated bus checks with the machine owner.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check the shaft clamp and restraint, lead entry, bend radius, junction terminals, shield and connector contamination. Check that the encoder actually follows the measured shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated cable checks.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Confirm the CAN High and CAN Low pair and bus-reference continuity on a disconnected branch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork and supply.\u003c\/strong\u003e Confirm the documented terminations at the ends of the bus. A qualified technician using an approved breakout fitted while off can measure the encoder supply from red to yellow. Check that the node uses the right bit rate, a unique ID and the intended NMT state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterpret symptoms.\u003c\/strong\u003e All nodes dropping out suggests bus power, termination, a short or network configuration. One dead node suggests its branch, voltage or ID. Correct network traffic with wrong position suggests scaling, mapping or preset. Changes synchronized with shaft or cable movement call for checking the clamp and harness.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse this standalone encoder with a compatible CANopen master implementing the DS-406 encoder profile. The POSITAL manual distinguishes connector\/cable UCD-CA01 units from connection-cap models with manual address and termination switches. Use the setup and EDS for the actual 2AW device, and confirm the controller’s bit rate and network topology. \u003ca href=\"https:\/\/www.posital.com\/media\/posital_fsimg\/manual-ixarc-ucd-ca.pdf\"\u003ePOSITAL CANopen UCD setup (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eFor this machine-axis encoder, commissioning means mounting alignment, count direction, scaling and machine datum. Read the old node settings and reference before disconnecting. Apply a preset only when permitted by the machine procedure, at standstill, then verify it against a known reference. POSITAL documents preset object 6003h in its UCD manual. A motor commutation angle, if required by a separate servo, belongs to that motor system. \u003ca href=\"https:\/\/www.posital.com\/media\/posital_fsimg\/manual-ixarc-ucd-ca.pdf\"\u003ePOSITAL preset and configuration procedure (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-CA01B-1312-HATS-2AW\/1618782\"\u003ePOSITAL 1618782 exact product page\u003c\/a\u003e. Download the device data sheet and use the Connection Plan and Drawings tabs for the exact lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.posital.com\/media\/posital_fsimg\/manual-ixarc-ucd-ca.pdf\"\u003ePOSITAL IXARC UCD CANopen manual (PDF)\u003c\/a\u003e. See sections on baud rate, node ID, PDO and preset.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.posital.com\/en\/canopen-encoder\"\u003ePOSITAL CANopen technology reference\u003c\/a\u003e. Network roles, messages and encoder integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51117036634277,"sku":"frt3","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/POSITALIXARCUCD-CA01B-1312-HATS-2AWCANopenEncoderTechnicalGuideServiceVisitforInstallation_Repair_Alignment.jpg?v=1794123585","url":"https:\/\/www.sparefaber.com\/ar\/products\/posital-ixarc-ucd-ca01b-canopen","provider":"SpareFaber","version":"1.0","type":"link"}