{"product_id":"renishaw-resolute-resa30-drive-cliq","title":"Renishaw RESOLUTE RESA30 DRIVE-CLiQ FS Encoder  | Technical Guide| Service Visit for Installation, Repair, Alignmentdv","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eSignal loss or position error after a ring or readhead change?\u003c\/strong\u003e SpareFaber can visit your UAE site to check RESA30 seating and runout, readhead clearance, interface wiring and drive diagnostics. Ask about alignment verification and bench evaluation of the matching components.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Renishaw RESOLUTE RESA30 DRIVE-CLiQ FS Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the readhead, ring and interface labels, ring diameter and section, controller model, mounting photos and when the alarm occurs. Tell us if the alarm repeats in the same angular region. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse the Renishaw setup LEDs and compatible Siemens diagnostics to check the drive link, head communication and signal quality around the complete ring. A dial indicator checks runout separately from the optical readout. Safety-related commissioning requires the complete validated procedure for the configured axis. Exact Mitchell TI-5000JX and TI-3000JX support for this optical DRIVE-CLiQ system was not verified. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/en\/download\/installation-guide-resolute-functional-safety-siemens-drive-cliq-encoder-system--145252\"\u003eRenishaw signal and safety verification (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eRenishaw RESOLUTE RESA30 DRIVE-CLiQ FS Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead the part numbers of \u003cstrong\u003eall three\u003c\/strong\u003e items. The readhead is ordered for a ring diameter and interface. The A-section and B-section RESA30 rings have separate mounting drawings. The single-input and dual-input interface boxes also differ.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"RESOLUTE FS DRIVE-CLiQ reference codes\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eRESOLUTE FS DRIVE-CLiQ reference codes\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eOrder identifier\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePart\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to match\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSA29DBA052B30S\u003c\/th\u003e\n\u003ctd\u003eRenishaw FS angular-head order example\u003c\/td\u003e\n\u003ctd\u003e29-bit Siemens DRIVE-CLiQ, Ø52 mm ring size, standard outlet, 3 m lead and sealed M12.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSA26D…\u003c\/th\u003e\n\u003ctd\u003e26-bit FS angular head family\u003c\/td\u003e\n\u003ctd\u003eRead the entire code for diameter, outlet, cable and termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA-9796-0575\u003c\/th\u003e\n\u003ctd\u003eSingle-head DRIVE-CLiQ interface\u003c\/td\u003e\n\u003ctd\u003eCheck revision and approved head and ring pair.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA-9796-0590\u003c\/th\u003e\n\u003ctd\u003eDual-head DRIVE-CLiQ interface\u003c\/td\u003e\n\u003ctd\u003eUse the approved dual-head mechanical and commissioning setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe 052 field describes ring diameter. It does not identify the ring’s A\/B cross-section or the required hub by itself. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-resolute-functional-safety-absolute-optical-encoder-system--141734?userLanguage=en\"\u003eRenishaw FS order nomenclature (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-resa-absolute-angle-encoder--129392?userLanguage=en\"\u003eRESA30 sections and sizes (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eRenishaw provides current RESOLUTE FS and RESA30 documentation. Confirm orderability and matching replacement for the exact full head, ring and interface numbers. Reviewed 7 November 2026. \u003ca href=\"https:\/\/www.renishaw.com\/en\/resolute-optical-absolute-encoder-series--37823\"\u003eRenishaw RESOLUTE series\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Renishaw RESOLUTE FS angular system with Ø52 mm RESA30\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eRenishaw RESOLUTE FS angular system with Ø52 mm RESA30\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue \/ condition\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eOptical absolute singleturn readhead with a stainless-steel RESA30 ring. Nominal scale pitch 30 µm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface \/ resolution\u003c\/th\u003e\n\u003ctd\u003eSiemens DRIVE-CLiQ via separate interface. SA29D order example uses 29-bit position. Installed accuracy depends on ring and mounting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e24 V from the DRIVE-CLiQ network to the interface. The sealed readhead connection has a separate 5 V circuit. System power ≤4.3 W in the safety manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHead geometry\u003c\/th\u003e\n\u003ctd\u003eNominal 0.8 mm rideheight, ±0.1 mm for a 52 mm ring in the referenced drawing. Standard rotary drawing gives yaw, pitch and roll tolerances of ±0.5°.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003eStandard head operating 0 to +80 °C and IP64. Interface operating 0 to +55 °C and IP67 with specified connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eResolution is the size of the reported increment. Ring eccentricity, tilt and mounting distortion still affect position accuracy. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/en\/download\/installation-guide-resolute-functional-safety-siemens-drive-cliq-encoder-system--145252\"\u003eRenishaw rotary installation and system specifications (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-resa-absolute-angle-encoder--129392?userLanguage=en\"\u003eRESA30 installed accuracy (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eMount the ring to the correct A- or B-section hub, then check its seating and runout with the method in the relevant drawing. Keep the scale surface clean. Use the readhead mounting drawing to set rideheight, pitch, yaw and roll. The Ø52 mm ring has a tighter rideheight allowance than the general drawing.\u003c\/p\u003e\n\u003cp\u003eFor the standard FS readhead, the rotary drawing specifies M3 mounting and recommended tightening torque \u003cstrong\u003e0.9–1.1 N·m\u003c\/strong\u003e. This value is for the standard readhead, separate from the ring fasteners and the UHV head. Check signal quality around the full ring. An excellent signal at one point can hide a runout or alignment problem elsewhere. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/en\/download\/installation-guide-resolute-functional-safety-siemens-drive-cliq-encoder-system--145252\"\u003eRenishaw rotary head and ring installation drawings (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-resa-absolute-angle-encoder--129392?userLanguage=en\"\u003eRESA30 A\/B mechanical drawings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe readhead reads the absolute pattern on the rotating ring and sends digital position through its link to the interface box. The interface connects to the Siemens DRIVE-CLiQ system, which carries communication and interface power. The two links have different signal and supply assignments. A controller can see the interface even if the head-to-ring optical signal is weak.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Renishaw FS manual, two distinct 8-way M12 connections\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eRenishaw FS manual, two distinct 8-way M12 connections\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCircuit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDRIVE-CLiQ link at interface\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSealed readhead M12, termination S\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ return\u003c\/th\u003e\n\u003ctd\u003e24 V pin 1, 0 V pin 5\u003c\/td\u003e\n\u003ctd\u003e5 V pin 2, 0 V pins 5 and 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommunications\u003c\/th\u003e\n\u003ctd\u003eRX+ \/ RX− pins 3 \/ 4. TX+ \/ TX− pins 7 \/ 6.\u003c\/td\u003e\n\u003ctd\u003eA+ \/ A− pins 3 \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShield and reserved contacts\u003c\/th\u003e\n\u003ctd\u003eCase shield. Use specified network lead.\u003c\/td\u003e\n\u003ctd\u003eCase shield. Pins 6 and 7 reserved.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the connector-face drawings and the interface port labels. The table is for the named Renishaw system. Apply the 24 V network supply only to the network link, and use the approved readhead-to-interface assembly. Use the dedicated JST map for an F or V termination. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/en\/download\/installation-guide-resolute-functional-safety-siemens-drive-cliq-encoder-system--145252\"\u003eRenishaw output signals and connector drawings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Renishaw connections and service parts\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eRenishaw connections and service parts\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePart or code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSA29DBA052B30S\u003c\/th\u003e\n\u003ctd\u003eReference readhead with integral 3 m cable and sealed M12 termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA-9796-0575 \/ A-9796-0590\u003c\/th\u003e\n\u003ctd\u003eSingle- or dual-input interface module. These are interface part numbers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDRIVE-CLiQ cable\u003c\/th\u003e\n\u003ctd\u003eSeparate approved cable from the Renishaw interface to the exact Siemens system. Confirm both ends, length and machine cable ID.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe RESA30 is an external axis feedback system. It has no universal in-motor loom. Use the maker’s approved assemblies for safety-related service, with the original routing and shield terminations. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-resolute-functional-safety-absolute-optical-encoder-system--141734?userLanguage=en\"\u003eReadhead cable codes and interface drawings (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/en\/download\/installation-guide-resolute-functional-safety-siemens-drive-cliq-encoder-system--145252\"\u003eApproved installation and electrical requirements (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSecure the axis and isolate it before checking the ring or connectors.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check the connector key and latch, bent pins, deposits, damaged shielding and cable support. Look for a displaced ring, rubbing, contamination or loose head bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck a separate detachable cable.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Leave the integral readhead and interface electronics out of a resistance test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck each link.\u003c\/strong\u003e With the OEM-approved breakout fitted while off, a qualified person can verify the network supply at the interface from pin 1 to 5. Use approved diagnostics for head power and communication. The two M12 connectors have different supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterpret position-dependent faults.\u003c\/strong\u003e A stable link and intermittent head signal at the same angle point toward ring runout, head geometry or scale condition. No interface response calls for network power and cable checks. Good position with a safety alarm calls for verifying the validated device combination and safety commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis guide covers the Renishaw FS rotary readhead and RESA30 ring with the dedicated Siemens DRIVE-CLiQ interface. Identify the exact Siemens control or drive, firmware, and safety configuration before replacement. Other RESOLUTE serial families and REXA30 rings have separate configuration rules. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-resolute-functional-safety-absolute-optical-encoder-system--141734?userLanguage=en\"\u003eRenishaw approved system combinations (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet mechanical alignment and check optical signal quality around a full turn before establishing the axis datum. Record the incoming scaling, direction and machine zero. Complete the Siemens and Renishaw commissioning and applicable safety checks for the actual axis. A motor commutation angle applies only when the system is configured for that purpose by the machine maker.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/en\/download\/installation-guide-resolute-functional-safety-siemens-drive-cliq-encoder-system--145252\"\u003eRenishaw FS Siemens DRIVE-CLiQ installation and safety manual (PDF)\u003c\/a\u003e. Rotary readhead setup, RESA30 A\/B ring drawings, safety commissioning and the two M12 pinouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-resolute-functional-safety-absolute-optical-encoder-system--141734?userLanguage=en\"\u003eRenishaw RESOLUTE FS data sheet (PDF)\u003c\/a\u003e. Use the Siemens DRIVE-CLiQ angular order table and interface diagrams.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-resa-absolute-angle-encoder--129392?userLanguage=en\"\u003eRenishaw RESA30 ring data sheet (PDF)\u003c\/a\u003e. Ring section, diameter, fit and accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/en\/resolute-absolute-optical-encoder-downloads--37856\"\u003eRenishaw RESOLUTE downloads\u003c\/a\u003e. Use the manual edition for the exact hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51117212205221,"sku":"sty7","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/RenishawRESOLUTERESA30DRIVE-CLiQFSEncoderTechnicalGuideServiceVisitforInstallation_Repair_Alignmentdv.jpg?v=1794122950","url":"https:\/\/www.sparefaber.com\/ar\/products\/renishaw-resolute-resa30-drive-cliq","provider":"SpareFaber","version":"1.0","type":"link"}