{"product_id":"renishaw-rgh22a-1vpp-linear","title":"Renishaw RGH22A 1 Vpp Optical Linear Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for RGH22A installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Renishaw RGH22A 1 Vpp Optical Linear Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA specialist can use the setup indication and approved differential receiver to compare A\/B amplitude and phase, reference and limits over travel. Verify any Mitchell fixture for this exact head and cable. The device is a linear readhead and does not use a motor-run fixture.\u003c\/p\u003e\n\u003ch2\u003eRenishaw RGH22A 1 Vpp Optical Linear Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eRGH22A\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRGH22A · RGH22A15L00A order-key example\u003c\/th\u003e\n\u003ctd\u003eA is analog dual limit. 15 means 1.5 m and L denotes the analog 15-way D-type.\u003c\/td\u003e\n\u003ctd\u003e00A is standard in the order key. Confirm the complete combination against the fitted label.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRGH22B\u003c\/th\u003e\n\u003ctd\u003eRelated single-limit analog head. Check termination code.\u003c\/td\u003e\n\u003ctd\u003eCompare limit\/setup output assignment before moving the cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRGH22D\u003c\/th\u003e\n\u003ctd\u003eSeparate digital variant in the same family.\u003c\/td\u003e\n\u003ctd\u003eCheck its output and connector drawing independently.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eRenishaw lists RGH22 as obsolete and no longer orderable. Its migration page gives candidate families. Verify their scale, mounting, output and reference requirements against the machine.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for RGH22A\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for RGH22A\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring method\u003c\/th\u003e\n\u003ctd\u003eNon-contact optical readhead on the compatible RGS20 scale system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProcess outputs\u003c\/th\u003e\n\u003ctd\u003eDifferential 1 Vpp analog A and B for RGH22A\/B. RGH22A has two limit outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder key example\u003c\/th\u003e\n\u003ctd\u003eA \/ 15 \/ L \/ 00A gives dual limits, 1.5 m cable, analog 15-way D-type and standard option. Confirm the actual label.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference and setup\u003c\/th\u003e\n\u003ctd\u003eUse the applicable reference mark and limit actuator arrangements. RGH22A uses contact 7 on L termination for Vq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/%28a76a7e13ca474c538f1ff1f9e301418b%29?userLanguage=en\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eClean and inspect the scale as permitted by the installation guide. Check ride height, yaw, pitch and roll using the specified datum faces and setup process. A change over the travel can indicate bracket deflection, damaged scale or a changing gap. Confirm alignment throughout travel before setting the datum.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eMovement over the scale generates two sinusoidal tracks. The downstream interpolator uses their phase for position. The reference mark provides a repeatable location and the limit outputs identify configured end positions. Diagnose signal strength, reference and limits as separate paths.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the Renishaw connection table for analog RGH22A\/B and the termination code on the label. The L connector is a 15-way analog D-type. For RGH22A the table assigns the clear wire on L contact 7 to Vq. Keep this separate from the RGH22B external setup use of that connection. Match the signal and shield table to the exact head and controller.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe 15 code describes the integral cable length. L is the analog D-type termination and has its own pin view. For a replacement head or extension, identify the installed connector, cable length, analog channel pairs, reference and both limits. Use an extension and receiver input that satisfy the Renishaw cable specifications.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal LED changes at one area of travel\u003c\/th\u003e\n\u003ctd\u003eCheck local scale contamination or damage, ride height and bracket movement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA\/B signal is healthy and reference will not repeat\u003c\/th\u003e\n\u003ctd\u003eInspect the reference actuator and setup, then verify the controller input and relevant conductor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOne limit fails after a replacement\u003c\/th\u003e\n\u003ctd\u003eConfirm dual-limit A type and the exact L pin assignment. Check Vq and actuator position separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse RGH22A with the documented RGS20 scale, reference and limit accessories and a compatible analog receiver. Check whether the original controller handles its limit and reference signals in the same connector.\u003c\/p\u003e\n\u003cp\u003eFor a later optical linear family, compare the installed scale and interface. \u003ca href=\"\/ar\/products\/renishaw-tonic-t1030-15a\"\u003eTONiC T1030-15A guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThis is scale-to-readhead alignment and machine datum commissioning. Adjust the head using the Renishaw setup procedure, confirm signal quality along the axis and validate reference and limits. For a retrofit, confirm geometry and electronics before moving the datum.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/%28a76a7e13ca474c538f1ff1f9e301418b%29?userLanguage=en\"\u003eMain technical PDF\u003c\/a\u003e. Renishaw RGH22 data sheet. Read the analog connections and ordering sections together.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/en\/--37826\"\u003eManufacturer reference\u003c\/a\u003e. Renishaw's current legacy-product reference, including RGH22 lifecycle and migration leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/rgh22-rgs20--113337?userLanguage=en\"\u003eRenishaw RGH22 RGS20 installation guide\u003c\/a\u003e. Scale fit, readhead setup and analog connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51125881208997,"sku":"TCG139","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/renishaw-rgh22a-1vpp-linear-service-guide.jpg?v=1794215853","url":"https:\/\/www.sparefaber.com\/ar\/products\/renishaw-rgh22a-1vpp-linear","provider":"SpareFaber","version":"1.0","type":"link"}