{"product_id":"schneider-electric-bmh1403p-classic-hiperface-128-periods-st-mt-technical-guide","title":"Schneider Electric BMH1403P Classic HIPERFACE 128 periods Singleturn \/ Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sparefaber-encoder-guide\"\u003e\n\u003cp\u003e\u003cstrong\u003eSchneider Electric BMH1403P · Classic HIPERFACE 128 periods\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE site visits and send-in evaluation for the Schneider Electric BMH1403P. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e\u003c\/p\u003e\n\u003cnav aria-label=\"Guide sections\"\u003e\u003cp\u003e\u003ca href=\"#identify\"\u003eFind your part\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mechanical-fit\"\u003eMechanical fit\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#availability\"\u003eAvailability\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDocuments\u003c\/a\u003e · \u003ca href=\"#faq\"\u003eFAQ\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the motor nameplate, complete part number and fitted feedback label. 140 mm flange. Stall reference with LXM32•D72N4. Optical feedback code 1 single-turn or 2 multiturn. Verify full suffix, mechanical drawing, brake and connector style.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eWhat to identify\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCatalogue reference\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor base\u003c\/td\u003e\n\u003ctd\u003eBMH1403P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange\u003c\/td\u003e\n\u003ctd\u003e140 × 140 mm catalogue flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical encoder code 1\u003c\/td\u003e\n\u003ctd\u003eSingle-turn, 128 sine\/cosine periods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical encoder code 2\u003c\/td\u003e\n\u003ctd\u003eMultiturn, 128 sine\/cosine periods and 4,096 turns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eInclude any special suffixes and clear photos of the mating connectors and the feedback mount.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eWhat specialist testing can establish\u003c\/h2\u003e\n\u003cp\u003eRead the fitted HIPERFACE identity and position on a supported setup and check the analogue tracks separately. Compare feedback data at motor and drive boundaries and preserve the original motor-specific data for service.\u003c\/p\u003e\n\u003cp\u003eSpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eReference specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCatalogue value\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eScope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque reference\u003c\/td\u003e\n\u003ctd\u003e24 N·m\u003c\/td\u003e\n\u003ctd\u003eCatalogue stall combination with LXM32•D72N4. Confirm the drive and cooling conditions on site.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-turn \/ multiturn\u003c\/td\u003e\n\u003ctd\u003eBoth optical codes in one guide\u003c\/td\u003e\n\u003ctd\u003eConfirm complete fitted code and label. Smaller analogue-period options have their own order details.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue position resolution\u003c\/td\u003e\n\u003ctd\u003e131,072 points\/revolution with the stated Lexium 32 combination\u003c\/td\u003e\n\u003ctd\u003eKeep drive interpolation, analogue periods and raw device resolution distinct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit\u003c\/h2\u003e\n\u003cp\u003eUse the BMH1403P drawing for flange\/pilot, shaft end, connector type and brake-length dimensions. Check the exact keyed or untapped shaft and brake\/connector suffix.\u003c\/p\u003e\n\u003cp\u003eCheck the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the Lexium 32 BMH motor feedback connection for the exact assembled motor. Check serial data, supply and analogue paths using the specified contact-side drawing. Keep power, brake and thermal leads identified independently.\u003c\/p\u003e\n\u003cp\u003eIdentify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eInternal wiring and machine cables\u003c\/h2\u003e\n\u003cp\u003eMatch the Schneider BMH encoder cordset and amplifier at both ends. Check mounting style, retention, connector contact view, length and flex rating. Use the full order table for the motor power cordset.\u003c\/p\u003e\n\u003cp\u003eSend clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObserved symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive rejects replacement feedback\u003c\/td\u003e\n\u003ctd\u003eMatch the optical 1\/2 order and readable identity to the actual motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial position reads but movement looks noisy\u003c\/td\u003e\n\u003ctd\u003eCheck the 128-period analogue tracks and screen together with the cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiturn position changed after work\u003c\/td\u003e\n\u003ctd\u003eVerify the turn configuration and the machine reference on the matched drive.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the installed drive reference, fitted encoder label and readable motor information before disturbing the holder. Verify direction and commutation under the appropriate Lexium commissioning procedure.\u003c\/p\u003e\n\u003cp\u003eCompare readable identification, position and turn scope to the exact feedback information, then verify the axis reference on the matching system.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and availability\u003c\/h2\u003e\n\u003cp\u003eRequest availability against the complete BMH1403P order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eLexium 32 LXM32•D72N4 is the reference for this proposal. Confirm drive size against the complete motor and application.\u003c\/p\u003e\n\u003cp\u003eSend the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/download.se.com\/files?filename=Catalog\u0026amp;p_Doc_Ref=DIA7ED2140501EN\"\u003eSchneider Electric Lexium 32, BMH and BSH catalogue DIA7ED2140501EN\u003c\/a\u003e. BMH motor\/drive combinations, BMH order-code table and 140\/190 mm outline drawings.\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/download.se.com\/files?p_Doc_Ref=0198441113825-EN\"\u003eSchneider Electric Lexium 32M hardware guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should I send for an evaluation?\u003c\/summary\u003e\u003cp\u003eSend the complete BMH1403P order, feedback label, connectors at both ends, drive order and the original fault or alarm.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan I match the feedback from the motor frame?\u003c\/summary\u003e\u003cp\u003eUse the order information above, then compare the actual feedback label, signals, drawings and reference procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan you check the motor at our site?\u003c\/summary\u003e\u003cp\u003eRequest a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003cdiv id=\"enquiry\"\u003e\n\u003ch2\u003eRequest service\u003c\/h2\u003e\n\u003cp\u003eSend the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51311082012837,"sku":"TCG2012","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/schneider-electric-bmh1403p-classic-hiperface-128-periods-st-mt-technical-guide-cover.jpg?v=1795541378","url":"https:\/\/www.sparefaber.com\/ar\/products\/schneider-electric-bmh1403p-classic-hiperface-128-periods-st-mt-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}