{"product_id":"sew-eurodrive-cfm71s-br-rh1m-feedback-technical-guide","title":"SEW-EURODRIVE CFM71S \/ BR \/ RH1M Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSEW-EURODRIVE CFM71S \/ BR \/ RH1M — RH1M resolver. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess a UAE site visit, installation or alignment work, or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eSEW-EURODRIVE CFM71S \/ BR \/ RH1M — motor feedback application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eRH1M; fitted label and connector to verify\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel \/ configuration identifier\u003c\/th\u003e\n\u003ctd\u003eCFM71S \/ BR \/ RH1M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor order scope\u003c\/th\u003e\n\u003ctd\u003eDocumented frame, brake and feedback configuration; not a complete winding, thermal-sensor or connector order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eRH1M resolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5908 only for the matching 12-contact M23 resolver connection; verify winding pairs, excitation and connector view.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eNamed SEW CMP\/CFM resolver evaluation, conditional on actual excitation, ratio, winding pairs, connector and supported tester setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5908 only for the matching 12-contact M23 resolver connection; verify winding pairs, excitation and connector view.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ memory scope\u003c\/th\u003e\n\u003ctd\u003eVerify excitation, winding pairs, transformation ratio and fitted alignment. RH1M has no serial motor memory.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eMotor-run evaluation is conditional on the exact TI-3000JX motor\/feedback profile, poles, phase order, alignment, power wiring, load restraint and amplifier envelope. A catalogue maximum or successful feedback bench test does not promise a full-rating run. Confirm the fitted brake circuit and controlled release before rotation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eMitchell names the SEW CMP\/CFM resolver family. The OEM BR outline is on page 101; RH1M values are on page 144. Verify installed software, the actual sensor option and fixture before connection. A bench result describes the tested configuration; it does not clear the drive, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe linked manufacturer document identifies this catalogue configuration. Current production, availability and any approved successor require confirmation against the complete fitted order. A downloadable manual does not prove present stock. Compare voltage, winding, mounting, shaft, brake, feedback, connector and stored motor-data requirements before accepting a replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback technology\u003c\/th\u003e\n\u003ctd\u003eRH1M resolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrame \/ brake \/ feedback configuration\u003c\/th\u003e\n\u003ctd\u003eCFM71S \/ BR \/ RH1M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor square flange\u003c\/th\u003e\n\u003ctd\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor shaft diameter\u003c\/th\u003e\n\u003ctd\u003e19 mm; see drawing for tolerances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall axial length including shaft\u003c\/th\u003e\n\u003ctd\u003e345 mm, with BR brake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutline reference\u003c\/th\u003e\n\u003ctd\u003ePrinted page 101 of 19424019\/EN, March 2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder scope\u003c\/th\u003e\n\u003ctd\u003eDocumented frame, brake and feedback configuration; not a complete winding, thermal-sensor or connector order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRH1M sensor\u003c\/th\u003e\n\u003ctd\u003eTwo-pole resolver; one resolver pole pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM excitation reference\u003c\/th\u003e\n\u003ctd\u003e7 V at 7 kHz; verify the fitted revision and permitted test setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransformation ratio\u003c\/th\u003e\n\u003ctd\u003e0.5 ±10%, CFM catalogue printed page 144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMemory scope\u003c\/th\u003e\n\u003ctd\u003eNo serial-encoder motor-memory read\/copy workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eService values\u003c\/th\u003e\n\u003ctd\u003eExact feedback coupling dimensions, pin map, tightening torque and permitted retention method require the fitted assembly drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eRH1M is a resolver. Excitation and both analogue winding responses must be assessed together through a full mechanical revolution. A lost winding pair, poor contact, incorrect excitation or altered phase relationship can each cause incorrect position. The two-pole designation describes the resolver, not the motor pole count. There is no serial data channel or retained multiturn revolution counter to diagnose.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming shaft datum, pilot, bolt circle, rear clearance, cable exit and feedback retention before removal. Inspect play, debris, moisture and damaged contacts. Follow the exact assembly drawing for fits and fasteners; motor flange dimensions do not establish encoder coupling dimensions or tightening torque. Use the CFM71S brake outline on printed page 101. Its 105 mm flange and 19 mm shaft are independent dimensions. Verify pilot, bolt circle, shaft projection, rear housing and cable bend clearance from that same drawing. The main BR drawing gives LS = 371 mm for the RH1L\/AK1H\/EK1H rear package. RH1M is 26 mm shorter, so 371 − 26 = 345 mm. Do not quote the uncorrected LS as RH1M length. Plug clearance and any hand-release arrangement need additional space beyond the stated axial envelope. \u003c\/p\u003e\n\u003cp\u003eCFM71S \/ BR \/ RH1M identifies a 105 mm square flange, 19 mm shaft and 345 mm overall axial length including the shaft, with BR brake. The complete winding, speed, thermal-sensor and connector suffixes remain to record from the fitted nameplate.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eKeep motor power, protective earth, feedback and temperature circuits separate. Match contact numbering, keying, gender and mating-face versus wire-side view. A mechanically mating connector does not establish a pin assignment. Establish excitation, sine and cosine winding pairs from the actual connection drawing. Check continuity and isolation only with the assembly disconnected and the permitted measurement method. Excitation frequency, transformation ratio and polarity must match the fitted resolver and selected profile. Do not use a HIPERFACE power\/data pin map for this resolver connection.\u003c\/p\u003e\n\u003cp\u003eTI-5908 only for the matching 12-contact M23 resolver connection; verify winding pairs, excitation and connector view.\u003c\/p\u003e\n\u003cp\u003eThe BR brake is a separate circuit from feedback. Its family code does not establish coil voltage, current, holding torque, release time or emergency-stop rating. Check the fitted brake label and OEM circuit, including the control and suppression components. Separate a failure to release or mechanical drag from a feedback fault. Never route brake power through the feedback fixture. Record release and re-engagement behaviour under an agreed, restrained test setup.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the internal encoder-to-motor loom separately from the external machine cable and bench fixture. The internal loom part number is not established by the frame or interface alone. Obtain both connector faces, the assembly diagram and the correct contact view. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation. A Mitchell test lead identifies a test connection; it is not an OEM replacement machine cable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentify the exact configuration\u003c\/th\u003e\n\u003ctd\u003eCFM71S \/ BR \/ RH1M identifies a 105 mm square flange, 19 mm shaft and 345 mm overall axial length including the shaft, with BR brake. The complete winding, speed, thermal-sensor and connector suffixes remain to record from the fitted nameplate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault during cable movement\u003c\/th\u003e\n\u003ctd\u003eAfter isolation and disconnection at both ends, inspect flex points, pin engagement, contamination and earlier repairs. Compare continuity and unintended shorts against the correct diagram, accounting for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnstable position or missing feedback\u003c\/th\u003e\n\u003ctd\u003eVerify the actual sensor profile, matched excitation or DC supply, contact view and fixture. Inspect both analogue paths where applicable. A connector that mates mechanically can still have an incompatible pin assignment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition reads but the drive rejects it\u003c\/th\u003e\n\u003ctd\u003eCheck the resolver winding relationship, phase convention and exact motor profile. A serial-memory reset is not an RH1M diagnostic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReplacement dimensions look close\u003c\/th\u003e\n\u003ctd\u003eCompare this exact flange, shaft, feedback housing, brake and connector arrangement with the linked drawing. Do not use magnet-stack length, family digits or a similar power rating as the complete mounting envelope.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHolding, drag and load restraint\u003c\/th\u003e\n\u003ctd\u003eThe BR brake is a separate circuit from feedback. Its family code does not establish coil voltage, current, holding torque, release time or emergency-stop rating. Check the fitted brake label and OEM circuit, including the control and suppression components. Separate a failure to release or mechanical drag from a feedback fault. Never route brake power through the feedback fixture. Record release and re-engagement behaviour under an agreed, restrained test setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003ePreserve incoming references and readable drive settings before disassembly. A smooth position reading alone does not prove electrical alignment or machine home position. Use the fitted SEW resolver alignment procedure and exact motor profile. Mitchell documents a common SEW convention of +U\/−V at 60 electrical degrees and +U\/−W at 120 electrical degrees for most applicable motors. Confirm the actual motor follows that convention before using it. RH1M has no serial motor memory from which to recover a unique offset. Preserve the mechanical reference, phase convention and drive parameters before removal; verify the machine reference separately after repair.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eCFM71S \/ BR \/ RH1M identifies a 105 mm square flange, 19 mm shaft and 345 mm overall axial length including the shaft, with BR brake. The complete winding, speed, thermal-sensor and connector suffixes remain to record from the fitted nameplate.\u003c\/p\u003e\n\u003cp\u003eRecord the compatibility chain separately: complete motor order, actual feedback option, internal loom, bulkhead, machine cable and drive configuration. Similar power, a familiar connector shell or a shared protocol name cannot establish the whole chain. Any proposed replacement must also satisfy the mechanical, electrical and stored-data requirements of the specific machine.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/27282690417947-SEW-Servo-Motors\" target=\"_blank\" rel=\"noopener\"\u003eMitchell — SEW Servo Motors\u003c\/a\u003e — Mitchell names the SEW CMP\/CFM resolver family. The OEM BR outline is on page 101; RH1M values are on page 144.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/18972764908827-SEW-Standard-Alignment\" target=\"_blank\" rel=\"noopener\"\u003eMitchell — SEW Standard Alignment\u003c\/a\u003e — Documented resolver examples; confirm the exact motor procedure\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/download.sew-eurodrive.com\/download\/pdf\/19424019.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSEW — CFM71–112, 19424019\/EN (03\/2017)\u003c\/a\u003e — Brake outline, printed page 101; overall axial length includes shaft\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/download.sew-eurodrive.com\/download\/pdf\/19424019.pdf#page=144\" target=\"_blank\" rel=\"noopener\"\u003eOEM feedback and package cross-check\u003c\/a\u003e — Resolver specification, page 144\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource review: 20 November 2026. Obtain complete fitted motor and feedback labels, service ID, internal loom details and the correct connector mating-face drawing. Confirm the linked document revision and enabled test setup before extending replacement, wiring or motor-run claims.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a CFM71S \/ BR \/ RH1M enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eMotor-run scope remains conditional on the exact motor\/feedback profile, poles, phase order, alignment, power wiring, restraint and amplifier envelope. Frame size or bench support does not establish full-rating run capability. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"assessment-record\"\u003e\u003ch2\u003eWhat a useful service record contains\u003c\/h2\u003e\n\u003cp\u003eKeep the incoming condition distinct from the result after cleaning, rewiring or adjustment. Record the exact alarm text, whether it appears at power-up or during motion, the direction and speed range involved, and whether temperature or cable position changes it. Include recent bearing, winding, feedback or drive-parameter work. These observations help decide whether a site visit can reproduce the fault or a detached assembly can answer the same question on the bench.\u003c\/p\u003e\n\u003cp\u003eAn evaluation report should identify the motor and feedback actually received, the tested connection boundary, selected profile, fixture, supply or excitation, and the observations obtained. Preserve the original memory report where applicable. Separate a confirmed defect from an unresolved condition and state any tests limited by missing drawings, mounting hardware or the machine itself. A repair recommendation should name the affected assembly and the evidence supporting it, with replacement availability and turnaround confirmed after inspection.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"related\"\u003e\u003ch2\u003eRelated technical guides\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"\/ar\/products\/sew-eurodrive-cfm71s-rh1m-feedback-technical-guide\"\u003eCorresponding CFM RH1M without-brake guide\u003c\/a\u003e — compare the separate outline, not just the frame.\u003c\/p\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51257620725925,"sku":"TCG904","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sew-eurodrive-cfm71s-br-rh1m-service-guide.jpg?v=1795194685","url":"https:\/\/www.sparefaber.com\/ar\/products\/sew-eurodrive-cfm71s-br-rh1m-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}