{"product_id":"sick-ahs36b-s3qc004096","title":"SICK AHS36B-S3QC004096 IO-Link Absolute Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eIO-Link encoder online with the wrong position?\u003c\/strong\u003e SpareFaber can check the 1093084 mount, M12 lead, master port, device identity and process data at your UAE site. A bench check with a compatible IO-Link master can separate a sensor fault from a controller or setup issue.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK AHS36B-S3QC004096 IO-Link Absolute Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the label, master and PLC model, port diagnostics, IODD revision, raw position and machine readout. Include the previous parameter set and a photo of the coupling if available. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a compatible IO-Link master and the correct IODD to check communication, identity, position, speed and parameters. Compare raw values against a known shaft movement and an independent reference. Keep a bench master isolated from the production configuration. Exact Mitchell TI-5000JX and TI-3000JX coverage for this IO-Link build was not verified. \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/2\/92\/092\/operating_instructions_ahs_ahm36_io_link_basic_absolute_encoder_de_en_im0078092.pdf\"\u003eSICK IO-Link Basic operating instructions (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSICK AHS36B-S3QC004096 IO-Link Absolute Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eLook for \u003cstrong\u003eAHS36B-S3QC004096\u003c\/strong\u003e and \u003cstrong\u003e1093084\u003c\/strong\u003e. The exact build is a Basic singleturn unit with 4096 maximum steps per revolution, 6 mm solid shaft, face-mount flange and four-contact M12 male. AHS and AHM distinguish singleturn and multiturn in this IO-Link family. Check the full code because the same housing family has more than one interface.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SICK IO-Link Basic and Advanced identification\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eSICK IO-Link Basic and Advanced identification\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel and part number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePosition and fit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eConnection \/ behavior\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAHS36B-S3QC004096 · 1093084\u003c\/th\u003e\n\u003ctd\u003eBasic singleturn 12-bit, Ø6 mm solid shaft × 12 mm, face flange\u003c\/td\u003e\n\u003ctd\u003eM12 four-contact. Pin 2 unused.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAHS36B-S5QC004096 · 1100069\u003c\/th\u003e\n\u003ctd\u003eBasic singleturn 12-bit, Ø8 mm solid shaft × 12 mm, face flange\u003c\/td\u003e\n\u003ctd\u003eM12 four-contact. Different shaft fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAHS36A-S3QC016384 · 1101573\u003c\/th\u003e\n\u003ctd\u003eAdvanced singleturn 14-bit, Ø6 mm × 12 mm, face flange\u003c\/td\u003e\n\u003ctd\u003eM12 four-contact. Advanced pin 2 can have a configured function.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAHM36B-S1QC012x12 · 1092009\u003c\/th\u003e\n\u003ctd\u003eBasic 12-bit singleturn plus 12-bit multiturn, Ø6 mm servo flange\u003c\/td\u003e\n\u003ctd\u003eM12 four-contact. Match the data model and flange.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/961\/dataSheet_AHS36B-S3QC004096_1093084_en.pdf\"\u003e1093084 exact data (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/6\/26\/426\/product_information_ahs_ahm36_io_link_en_im0078426.pdf\"\u003eSICK IO-Link model and part-number tables (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eSICK publishes an exact 1093084 data sheet. Confirm current lifecycle, orderability and successor against that part number with SICK. The AHS\/AHM36 family also contains builds with different interfaces and mechanics. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/961\/dataSheet_AHS36B-S3QC004096_1093084_en.pdf\"\u003eSICK 1093084 datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SICK 1093084 exact data\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSICK 1093084 exact data\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition\u003c\/th\u003e\n\u003ctd\u003eSingleturn, 4096 positions\/revolution maximum. Configurable steps per revolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eIO-Link 1.1 COM3, 230.4 kbaud, cycle time ≤3.2 ms according to the exact sheet. Position and speed process data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply and consumption\u003c\/th\u003e\n\u003ctd\u003e18–30 V DC and ≤1.5 W on the exact SICK datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMount and speed\u003c\/th\u003e\n\u003ctd\u003eØ6 mm solid shaft with flat, 12 mm length, face-mount flange, up to 9000 rpm. 40 N radial and 20 N axial maximum shaft loading.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003eIP65. Operating −20 to +70 °C without condensation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/961\/dataSheet_AHS36B-S3QC004096_1093084_en.pdf\"\u003eSICK exact operating limits and drawings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eMatch the face-mount pilot, screw pattern, shaft diameter and insertion length to the exact dimensional drawing. Use a suitable separate coupling so the encoder is driven without binding or imposing side load. Under isolation check for a loose setscrew, misalignment and a connector forced by cable routing. Confirm the machine bracket and coupling dimensions before selecting a replacement. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/961\/dataSheet_AHS36B-S3QC004096_1093084_en.pdf\"\u003e1093084 face-mount dimensional drawing (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/2\/92\/092\/operating_instructions_ahs_ahm36_io_link_basic_absolute_encoder_de_en_im0078092.pdf\"\u003eSICK mounting guidance (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe magnetic encoder sends digital process data over the C\/Q conductor to an IO-Link master port. The master handles parameter access and presents data to the PLC. The IODD describes the device and parameter layout. A valid link with incorrect position can be a counting direction, resolution, preset or PLC mapping issue. Compare master raw position and speed with the PLC value before changing the encoder. One revolution wraps in singleturn mode. \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/2\/92\/092\/operating_instructions_ahs_ahm36_io_link_basic_absolute_encoder_de_en_im0078092.pdf\"\u003eIO-Link process data and parameter sections (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/ioddfinder.io-link.com\/\"\u003eIO-Link IODD Finder\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"1093084 Basic M12 male connection\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003e1093084 Basic M12 male connection\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eReference lead colour\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003eBrown\u003c\/td\u003e\n\u003ctd\u003eL+ encoder supply (18–30 V DC on exact datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003ctd\u003eUnused for Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003eL−, 0 V supply return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003ctd\u003eC\/Q, IO-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the numbered mating view on the datasheet. Compare actual harness continuity against that view. Advanced and Inox tables have distinct pin functions and applicable ratings. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/961\/dataSheet_AHS36B-S3QC004096_1093084_en.pdf\"\u003e1093084 Basic assignment (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThis external unit connects directly to the machine IO-Link master. For the factory M12 male, SICK lists \u003cstrong\u003eYF2A14-020UB3M2A14\u003c\/strong\u003e (2096000, 2 m) and \u003cstrong\u003eYF2A14-050UB3M2A14\u003c\/strong\u003e (2096001, 5 m), A-coded female-to-male PUR cordsets. \u003cstrong\u003eDOS-1204-G\u003c\/strong\u003e (6007302) is the listed field-wireable female with screw terminals. Verify the master end, environmental rating and machine routing. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/961\/dataSheet_AHS36B-S3QC004096_1093084_en.pdf\"\u003eSICK 1093084 accessory table (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSecure and isolate the axis and feedback supply before mechanical or cable work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead and record.\u003c\/strong\u003e Note the port status, device ID, raw position and whether the fault began after a change. Under isolation, check the coupling, M12 key and seating, pins, moisture, damaged locking threads and strain relief.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the cordset.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Verify the link conductor on contact 4 and the two supply contacts. For a simple passive cordset, compare the master and sensor ends pin by pin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck supply and port.\u003c\/strong\u003e A qualified technician can use an approved breakout installed while isolated, then check L+ to L− under load with motion secured under the site procedure. Verify that the master port is in IO-Link mode and has the matching IODD and data layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate faults.\u003c\/strong\u003e If the link and raw word are stable while machine position is wrong, compare the mechanical coupling, preset and PLC scaling. If the raw word freezes during a controlled movement, check coupling first, then compare with a known-good compatible cordset and master port. Preserve the production setup before substitution.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThe SICK product information lists absolute position measurement for packaging, handling and machine building. In a PLC system, select a compatible IO-Link master, import the correct IODD and verify process data width and decoding on the master and PLC. CANopen or SSI versions require their own documentation. \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/6\/26\/426\/product_information_ahs_ahm36_io_link_en_im0078426.pdf\"\u003eSICK application and type-code reference (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/2\/92\/092\/operating_instructions_ahs_ahm36_io_link_basic_absolute_encoder_de_en_im0078092.pdf\"\u003eIO-Link Basic installation (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCommission this external position encoder by checking coupling, count direction, steps per turn and machine datum. Preserve the device parameters and current displayed position before replacing it. Apply the approved preset through the IO-Link parameter interface for this Basic model with the axis stationary at its known reference. Verify one full turn and wrap at controlled speed before handing back the machine. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/961\/dataSheet_AHS36B-S3QC004096_1093084_en.pdf\"\u003eBasic parameter and pin functions (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/2\/92\/092\/operating_instructions_ahs_ahm36_io_link_basic_absolute_encoder_de_en_im0078092.pdf\"\u003eSICK preset and configuration sections (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/961\/dataSheet_AHS36B-S3QC004096_1093084_en.pdf\"\u003eSICK AHS36B-S3QC004096 1093084 (PDF)\u003c\/a\u003e. Exact specifications, pin numbers, mounting dimensions and cordsets.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/2\/92\/092\/operating_instructions_ahs_ahm36_io_link_basic_absolute_encoder_de_en_im0078092.pdf\"\u003eSICK AHS\/AHM36 IO-Link Basic operating instructions (PDF)\u003c\/a\u003e. Installation, IODD, settings, diagnostics and preset.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/6\/26\/426\/product_information_ahs_ahm36_io_link_en_im0078426.pdf\"\u003eSICK AHS\/AHM36 IO-Link product information (PDF)\u003c\/a\u003e. Variants and differences between Basic and Advanced.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/ioddfinder.io-link.com\/\"\u003eIO-Link IODD Finder\u003c\/a\u003e. Look up the matching device and revision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118237188261,"sku":"TXG04","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/SICKAHS36B-S3QC004096IO-LinkAbsoluteEncoder.jpg?v=1794144471","url":"https:\/\/www.sparefaber.com\/ar\/products\/sick-ahs36b-s3qc004096","provider":"SpareFaber","version":"1.0","type":"link"}