{"product_id":"sick-ekm36","title":"SICK EKM36 HIPERFACE DSL Encoder | Technical Guide \u0026 Service Visit for installation, Signal Check,Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eTracing a SICK EKM36 HIPERFACE DSL fault?\u003c\/strong\u003e SpareFaber can visit your UAE site to check the drive diagnostics, hybrid motor cable, shielding and feedback setup. Ask about bench evaluation, replacement selection or commutation verification for your motor.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my SICK part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a feedback fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK EKM36 HIPERFACE DSL technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or bench evaluation\u003c\/h2\u003e\n\u003cp\u003eRequest a site visit if the fault follows cable movement, starts when the drive enables or returns when the motor warms up. Share the full motor and encoder codes, drive model, fault history and connector photos. For send-in evaluation, keep the original encoder and motor together when alignment is in question. SICK specifies replacement of a defective EKM36-2 assembly. Rockwell assigns internal Kinetix VPL service to its qualified personnel. \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/7\/07\/407\/operating_instructions_eks36_2_ekm36_2..._motor_feedback_system_rotary_hiperface_dsl%C2%AE_de_en_fr_it_es_im0068407.pdf#page=5\"\u003eSICK operating instructions (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/vpl-in001_-en-p.pdf#page=2\"\u003eRockwell VPL installation instructions (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell’s \u003cstrong\u003eTI-5000JX\u003c\/strong\u003e with the \u003cstrong\u003eTI-5106\u003c\/strong\u003e HIPERFACE DSL adapter, matched test lead and Athena profile can check count and direction, read encoder errors, display electrical angle and read memory on supported OEM motors. Mitchell lists \u003cstrong\u003eTI-5734\u003c\/strong\u003e for most VPL motors, \u003cstrong\u003eTI-5738\u003c\/strong\u003e for certain larger M40 VP builds and \u003cstrong\u003eTI-5743\u003c\/strong\u003e for direct-to-encoder DSL testing. Check the motor connector and profile first. These are bench leads. \u003ca href=\"https:\/\/www.mitchell-electronics.com\/ti-5106-sick-hiperface-dsl-hardware-adapter-module\/\"\u003eMitchell TI-5106 coverage\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4410411502363-Allen-Bradley-VPL-motor-setup\"\u003eMitchell VPL setup and test leads\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eMitchell demonstrates a \u003cstrong\u003eTI-3000JX\u003c\/strong\u003e run test on a supported VPL motor. A run test requires the correct motor and amplifier setup, a secured fixture, matched cables, and verified feedback and commutation before rotation. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4410411502363-Allen-Bradley-VPL-motor-setup\"\u003eMitchell VPL run-test reference\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSICK EKM36 technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment and memory\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eRead the full EKM36 label\u003c\/h2\u003e\n\u003cp\u003eThe reference model here is \u003cstrong\u003eEKM36-2KF0B018A\u003c\/strong\u003e, SICK item \u003cstrong\u003e1084235\u003c\/strong\u003e. \u003cstrong\u003eM\u003c\/strong\u003e means multiturn, \u003cstrong\u003e2\u003c\/strong\u003e identifies the safety variant, \u003cstrong\u003eK\u003c\/strong\u003e is the motor-cable integration option and \u003cstrong\u003e18\u003c\/strong\u003e specifies the bits per revolution. For the hardware revision, look at \u003cstrong\u003eA\u003c\/strong\u003e or \u003cstrong\u003eB\u003c\/strong\u003e after \u003cstrong\u003eKF0\u003c\/strong\u003e. The final \u003cstrong\u003eA\u003c\/strong\u003e is a separate character. Write down the exact motor code and serial number as well.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Searchable SICK EKM36 and EKS36 part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eExact models with the same tapered-shaft and spring-plate mounting style\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel and SICK item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePosition data\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVariant and DSL connector\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEKM36-2KF0B018A\u003cbr\u003e1084235\u003c\/th\u003e\n\u003ctd\u003e18 bits per turn, 4,096 turns\u003c\/td\u003e\n\u003ctd\u003eSafety variant. Hardware B has a housing connection on pin 4.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEKM36-2KF0A018A\u003cbr\u003e1054316\u003c\/th\u003e\n\u003ctd\u003e18 bits per turn, 4,096 turns\u003c\/td\u003e\n\u003ctd\u003eEarlier safety variant. Hardware A uses pins 2 and 3 for DSL.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEKM36-0KF0B018A\u003cbr\u003e1084233\u003c\/th\u003e\n\u003ctd\u003e18 bits per turn, 4,096 turns\u003c\/td\u003e\n\u003ctd\u003eStandard variant. Hardware B adds the housing connection on pin 4.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEKM36-0KF0A018A\u003cbr\u003e1053849\u003c\/th\u003e\n\u003ctd\u003e18 bits per turn, 4,096 turns\u003c\/td\u003e\n\u003ctd\u003eEarlier standard variant. Hardware A uses pins 2 and 3 for DSL.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEKM36-2KF0B020A\u003cbr\u003e1084236\u003c\/th\u003e\n\u003ctd\u003e20 bits per turn, 4,096 turns\u003c\/td\u003e\n\u003ctd\u003eSafety variant. Hardware B with a higher position resolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEKS36-2KF0B018A\u003cbr\u003e1084231\u003c\/th\u003e\n\u003ctd\u003e18 bits, single-turn\u003c\/td\u003e\n\u003ctd\u003eSafety variant. Hardware B with position within one revolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eMatch resolution, safety variant and motor configuration as well as fit. If your label reads \u003cstrong\u003e1053849\u003c\/strong\u003e, see the \u003ca href=\"https:\/\/www.sparefaber.com\/products\/sick-ekm36-0kf0a018a-1053849\"\u003eSpareFaber listing for that exact spare\u003c\/a\u003e. \u003ca href=\"https:\/\/www.sick.com\/media\/familyoverview\/1\/51\/751\/familyOverview_EKS-EKM36_g192751_en.pdf#page=3\"\u003eSICK type code and ordering table (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cfigure style=\"max-width: 23rem; margin: 1rem 0;\"\u003e\n\u003cimg src=\"https:\/\/www.sparefaber.com\/cdn\/shop\/files\/Sick_Motor_feedback_EKM36-0KF0A018A_1053849_10.jpg?v=1785938733\u0026amp;width=1024\" alt=\"SICK EKM36-0KF0A018A hardware A label showing item number 1053849\" loading=\"lazy\" style=\"width: 100%; height: auto;\"\u003e\n\u003cfigcaption\u003eHardware A label example from SpareFaber stock. Read item 1053849 beside “Ident. Nr.” on this unit.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eSICK identifies hardware B as the successor to hardware A. For the 18-bit multiturn models above, \u003cstrong\u003e1054316\u003c\/strong\u003e corresponds to \u003cstrong\u003e1084235\u003c\/strong\u003e and \u003cstrong\u003e1053849\u003c\/strong\u003e to \u003cstrong\u003e1084233\u003c\/strong\u003e. Check the motor maker’s approved replacement and shielding arrangement before a swap. SICK still publishes a data sheet for 1084235. Current production or stock for that exact B item and OEM-coded units requires manufacturer confirmation. Checked 7 November 2026. \u003ca href=\"https:\/\/support.sick.com\/sick-knowledgebase\/article\/?code=KA-02727\"\u003eSICK hardware A-to-B notice\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications for EKM36-2KF0B018A\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SICK 1084235 specifications\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSICK item 1084235, hardware B\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue for this part\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring method\u003c\/th\u003e\n\u003ctd\u003eOptical absolute multiturn, digital HIPERFACE DSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution and range\u003c\/th\u003e\n\u003ctd\u003e18 bits (262,144 positions per revolution), 4,096 distinguishable turns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSystem accuracy\u003c\/th\u003e\n\u003ctd\u003e±120 arcseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply and current\u003c\/th\u003e\n\u003ctd\u003e7–12 V DC, 8 V recommended. ≤150 mA operating current with the specified interface circuit. See the startup current diagram separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUser memory\u003c\/th\u003e\n\u003ctd\u003e8,192 bytes. The motor maker determines what data is stored.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft and housing\u003c\/th\u003e\n\u003ctd\u003e1:3 tapered shaft, spring stator coupling, Ø35 mm body. IP40 with connectors inserted and cover closed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermissible shaft movement\u003c\/th\u003e\n\u003ctd\u003eStatic ±0.1 mm radial \/ ±0.5 mm axial. Dynamic ±0.05 mm radial \/ ±0.1 mm axial.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder operating speed\u003c\/th\u003e\n\u003ctd\u003e≤9,000 rpm in the B-version data sheet. Observe the motor’s own limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to +115 °C with the stated thermal connection. Internal sensor temperature ≤125 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety variant\u003c\/th\u003e\n\u003ctd\u003eSIL 2 \/ PL d capability in a suitable drive and installation, subject to SICK’s integration and commissioning conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe archived \u003cstrong\u003e1054316\u003c\/strong\u003e sheet gives a different speed specification for hardware A, including a separate limit at switch-on or reset. Check the approved limit for the fitted part and motor before replacing it. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/9\/49\/949\/dataSheet_EKM36-2KF0B018A_1084235_en.pdf\"\u003eSICK 1084235 data sheet (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/1\/61\/361\/dataSheet_EKM36-2KF0A018A__1054316_en.pdf\"\u003eSICK 1054316 archived data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eHow the tapered shaft fits the motor\u003c\/h2\u003e\n\u003cp\u003eThe encoder’s tapered shaft seats in the motor shaft. Its M4 thread holds that joint together. Two M3 screws secure the spring stator plate to the motor flange on the documented Ø38 mm bolt circle. The plate holds the body against rotation while accommodating the designed shaft movement. Compare the taper, axial seating and fixing holes with SICK’s attachment drawing. Where OEM service access permits, check that the joint is seated, the plate fasteners are secure and the lead is free of pinching.\u003c\/p\u003e\n\u003cp\u003eFor \u003cstrong\u003eEKM36-2\u003c\/strong\u003e tapered mounting, SICK’s assembly instructions specify tool \u003cstrong\u003eBEF-MW-EKX36 (2060224)\u003c\/strong\u003e, final shaft tightening of \u003cstrong\u003e4 N·m with a +0.8 N·m tolerance\u003c\/strong\u003e, and \u003cstrong\u003e0.8 ±0.08 N·m\u003c\/strong\u003e for each M3 plate screw. Before the taper seats, the manual limits the thread torque to \u003cstrong\u003e0.8 N·m\u003c\/strong\u003e. Follow the specified sequence and keep the taper clean and dry. Use these figures for the illustrated SICK assembly and check the motor service procedure. \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/7\/07\/407\/operating_instructions_eks36_2_ekm36_2..._motor_feedback_system_rotary_hiperface_dsl%C2%AE_de_en_fr_it_es_im0068407.pdf#page=5\"\u003eSICK EKM36-2 §4 and Fig. 4 (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/9\/49\/949\/dataSheet_EKM36-2KF0B018A_1084235_en.pdf#page=4\"\u003eSICK outline and attachment drawings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eHow HIPERFACE DSL exchanges information\u003c\/h2\u003e\n\u003cdiv style=\"background: #eaf5f4; border-left: 4px solid #237e75; border-radius: 0.35rem; padding: 0.75rem 1rem;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTwo conductors carry encoder power and digital communication.\u003c\/strong\u003e The drive’s DSL master supplies DC and exchanges messages on the same DSL+ and DSL− pair. In a one-cable motor, that feedback pair runs alongside separate motor power and brake conductors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe drive receives absolute shaft position, status and supported diagnostic data. It uses the position to calculate speed and commutate the motor. A steady DC voltage across the pair establishes that the supply is present. A DSL master is needed to determine whether the data is healthy. Legacy HIPERFACE, as used by the SKM36, uses a separate analog sine\/cosine path and a different interface. \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/8\/08\/608\/technical_information_hiperface_dsl_master_safety_integration_manual_en_im0056608.pdf\"\u003eSICK HIPERFACE DSL master manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified DSL pins at the encoder, motor and drive\u003c\/h2\u003e\n\u003cp\u003eUse the numbered view in SICK’s connector drawing and check the key and molded pin numbers on the actual plug. With the latch feature above the pins as drawn, SICK numbers the communication connector 1–4 left to right. Verify pin numbers before working from the opposite side. The table lists the \u003cstrong\u003eencoder\u003c\/strong\u003e connector, with SICK lead colours where specified.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SICK EKM36 A and B encoder-side pins\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSICK communication connector, positions 1–4\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHardware A\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHardware B\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSICK lead\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003eUnused\u003c\/td\u003e\n\u003ctd\u003eUnused\u003c\/td\u003e\n\u003ctd\u003eLeave free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003e+U\u003csub\u003eS\u003c\/sub\u003e \/ DSL+\u003c\/td\u003e\n\u003ctd\u003e+U\u003csub\u003eS\u003c\/sub\u003e \/ DSL+\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003e0 V \/ DSL−\u003c\/td\u003e\n\u003ctd\u003e0 V \/ DSL−\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003eUnused\u003c\/td\u003e\n\u003ctd\u003eHousing \/ shield contact\u003c\/td\u003e\n\u003ctd\u003eShield or drain on the specified B lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eSICK lists \u003cstrong\u003eJST GHR-04V-S\u003c\/strong\u003e as the mating housing for the 1084235 DSL connector. Its separate \u003cstrong\u003etemperature-sensor socket\u003c\/strong\u003e uses pin 1 T+ and pin 2 T−, with \u003cstrong\u003eHarwin M80-8990205\u003c\/strong\u003e as the recommended mate. Follow SICK’s insulation requirements for that thermistor circuit. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/9\/49\/949\/dataSheet_EKM36-2KF0B018A_1084235_en.pdf#page=5\"\u003eSICK 1084235 connector drawings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eFor the \u003cstrong\u003eRockwell VPL-B1306C-PJ14AA\u003c\/strong\u003e M23 SpeedTec motor connector, \u003cstrong\u003eE\u003c\/strong\u003e is DATA+ and \u003cstrong\u003eH\u003c\/strong\u003e is DATA−. The VPL-B1654D M40 diagram instead uses \u003cstrong\u003eL\u003c\/strong\u003e for DATA+ and \u003cstrong\u003eH\u003c\/strong\u003e for DATA−. At the \u003cstrong\u003eKinetix 5500\u003c\/strong\u003e drive’s MF connector, \u003cstrong\u003eMF-1\u003c\/strong\u003e is D+ (blue) and \u003cstrong\u003eMF-2\u003c\/strong\u003e is D− (white\/blue) on the specified Rockwell lead. Use the applicable OEM diagram at each end. These hybrid motor plugs also contain motor power and brake contacts. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/vpl-in001_-en-p.pdf#page=10\"\u003eRockwell VPL motor plug drawings (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/2198-um001_-en-p.pdf#page=85\"\u003eKinetix 5500 MF connector, Table 45 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eInternal leads, housings and hybrid motor cables\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Verified EKM36 internal lead part numbers\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSICK in-motor feedback leads with an encoder connector and flying leads\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSICK type\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOrder no.\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eLength and termination\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDOL-0B02-G0M2XC1\u003c\/th\u003e\n\u003ctd\u003e2062083\u003c\/td\u003e\n\u003ctd\u003e200 mm, two-wire twisted unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDOL-0B02-G0M3XC1\u003c\/th\u003e\n\u003ctd\u003e2091818\u003c\/td\u003e\n\u003ctd\u003e300 mm, two-wire twisted unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDOL-0B02-G0M4XC1\u003c\/th\u003e\n\u003ctd\u003e2086286\u003c\/td\u003e\n\u003ctd\u003e400 mm, two-wire twisted unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDOL-0B03-G0M4XC1\u003c\/th\u003e\n\u003ctd\u003e2087314\u003c\/td\u003e\n\u003ctd\u003e430 mm, shielded DSL pair with drain to pin 4 for hardware B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eSICK suggests shielded leads above 200 mm inside the motor. Match the OEM’s approved routing, shield termination and lead length. The SICK leads listed here terminate in flying leads at the motor end. Obtain the complete PCB-to-bulkhead loom or mating connector from the motor maker by exact motor code. \u003ca href=\"https:\/\/support.sick.com\/sick-knowledgebase\/article\/?id=85207e71-77c6-4085-a51f-d8fcacd1cd67\"\u003eSICK in-motor cable options\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eRockwell lists \u003cstrong\u003e2090-CSxM1DF\u003c\/strong\u003e external hybrid cables for Kinetix 5500 and \u003cstrong\u003e2090-CSxM1DG\u003c\/strong\u003e with longer feedback leads for the Kinetix 5700 layout. The \u003cstrong\u003e2198-KITCON-DSL\u003c\/strong\u003e is the Kinetix 5500 drive-end connector kit. Select the complete cable number by motor, drive, brake and length. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/2198-um001_-en-p.pdf#page=85\"\u003eRockwell cable and shield-clamp guidance (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks on the machine\u003c\/h2\u003e\n\u003cdiv style=\"background: #eaf5f4; border-left: 4px solid #237e75; border-radius: 0.35rem; padding: 0.75rem 1rem;\"\u003e\n\u003cp\u003e\u003cstrong\u003eRead the drive before opening the cable.\u003c\/strong\u003e On a Kinetix 5500 with the equipment in its approved diagnostic state, open \u003cstrong\u003eDiagnostics → Encoder Diagnostics\u003c\/strong\u003e. Record \u003cstrong\u003eSUPP VOLT\u003c\/strong\u003e, \u003cstrong\u003eLINK QUAL\u003c\/strong\u003e, \u003cstrong\u003eRSSI\u003c\/strong\u003e and the fault log. Rockwell specifies 100% link quality and 80–100% RSSI on this display. Persistent drops warrant a check of the feedback shield bond and cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"HIPERFACE DSL fault isolation by symptom\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eWhich part of the system to check next\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNext check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply low or encoder data unavailable\u003c\/th\u003e\n\u003ctd\u003eCheck the drive’s feedback supply and the two-wire path. If communication is down, the encoder voltage readout may be unavailable. Use the approved breakout procedure below.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage in range, link drops or FLT S45 on Kinetix 5500\u003c\/th\u003e\n\u003ctd\u003eS45 indicates feedback data loss. Check both plugs, cable flex points, shield bonding and the approved hybrid cable before replacing the encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLink established, FLT S47 or encoder status fault\u003c\/th\u003e\n\u003ctd\u003eS47 is a feedback device failure report. Save the full code and details. Check the encoder status and verify on an approved known-good feedback path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLink healthy, rough start or wrong position after service\u003c\/th\u003e\n\u003ctd\u003eVerify the motor data, shaft attachment, feedback direction and motor-specific commutation offset. If the motor position tracks but the load slips, inspect the coupling and load path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated checks.\u003c\/strong\u003e Lock out power, secure the axis and suspended or stored-energy loads, and verify discharge per the drive manual. With the cable disconnected at both ends, check for backed-out or bent pins, dirt, moisture and latch damage. Meter each DSL conductor end to end, then check for shorts between the pair and to the housing or shield. Flex only the disconnected cable during the check. Compare shield continuity with the OEM drawing and keep an insulation tester away from the encoder and drive electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowered supply check for qualified personnel.\u003c\/strong\u003e Fit an approved breakout with power isolated. With the axis secured in the OEM-approved diagnostic state, put the meter in DC volts with the leads in V and COM. At the \u003cstrong\u003e1084235 encoder end\u003c\/strong\u003e, measure red on \u003cstrong\u003e2 (DSL+)\u003c\/strong\u003e and black on \u003cstrong\u003e3 (DSL−)\u003c\/strong\u003e under load. Expect \u003cstrong\u003e7–12 V DC\u003c\/strong\u003e. Compare with the approved drive-side reading if low. Keep the shield on its specified path. Use a DSL diagnostic tool to check communication.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/2198-um001_-en-p.pdf#page=103\"\u003eKinetix 5500 Encoder Diagnostics (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.sick.com\/_entity\/annotation\/00c9e3b2-af46-f011-877a-7c1e524dab54\"\u003eSICK DSL communication monitoring note (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eDocumented motor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMitchell documents EKM36 on the tested \u003cstrong\u003eAllen-Bradley VPL-B1306C-PJ14AA\u003c\/strong\u003e. Rockwell confirms that its \u003cstrong\u003eP\u003c\/strong\u003e option is 18-bit multiturn HIPERFACE DSL. Rockwell documents \u003cstrong\u003eEKM36-2\u003c\/strong\u003e for the \u003cstrong\u003eW\u003c\/strong\u003e safety feedback option on specified VPL frames. Confirm the encoder label and the motor’s approved spare for the actual assembly. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4410411502363-Allen-Bradley-VPL-motor-setup\"\u003eMitchell VPL example\u003c\/a\u003e · \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/vpl-in001_-en-p.pdf#page=4\"\u003eRockwell VPL functional-safety options (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eKollmorgen’s AKM connectivity table identifies \u003cstrong\u003eGF\u003c\/strong\u003e as the EKM36 multiturn DSL option and \u003cstrong\u003eGE\u003c\/strong\u003e as the EKS36 single-turn option. Use the complete AKM code and the drive-specific hybrid cable or feedback interface for that build. \u003ca href=\"https:\/\/www.kollmorgen.com\/en-us\/developer-network\/reference-table-connectors-feedback\"\u003eKollmorgen AKM connector and feedback options\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eCommutation angle and encoder memory\u003c\/h2\u003e\n\u003cp\u003eMitchell documents a motor-specific commutation reference stored with the motor data on Allen-Bradley VP DSL applications. Read and save the original report and memory using the matched VP DSL profile while the encoder is readable. Record the incoming electrical angle, phase convention and feedback direction. Use that motor’s reference for alignment. If the original data is unreadable, obtain the approved recovery procedure for that motor and serial number.\u003c\/p\u003e\n\u003cp\u003eFor an approved replacement, restore only the verified OEM data for that same motor using the approved procedure. Read it back and verify commutation and position independently before a guarded test. On safety applications, follow the OEM inspection and recommissioning procedure, including SICK’s specified feedback type verification. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/14049548139675-WinTI5000JX-is-being-replaced-with-Athena-New-Features\"\u003eMitchell VP DSL alignment memory support\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/7\/07\/407\/operating_instructions_eks36_2_ekm36_2..._motor_feedback_system_rotary_hiperface_dsl%C2%AE_de_en_fr_it_es_im0068407.pdf#page=6\"\u003eSICK EKM36-2 commissioning (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, manuals and test references\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/9\/49\/949\/dataSheet_EKM36-2KF0B018A_1084235_en.pdf\"\u003eSICK 1084235 exact data sheet (PDF)\u003c\/a\u003e with dimensions, plug drawings and accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/7\/07\/407\/operating_instructions_eks36_2_ekm36_2..._motor_feedback_system_rotary_hiperface_dsl%C2%AE_de_en_fr_it_es_im0068407.pdf\"\u003eSICK EKS36-2 \/ EKM36-2 operating instructions, 8020309\/1JUA (PDF)\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/6\/06\/406\/operating_instructions_eks36_ekm36_motor_feedback_system_rotary_hiperface_dsl%C2%AE_de_en_im0068406.pdf\"\u003eSICK EKS36-0 \/ EKM36-0 operating instructions, 8020285\/1R6J (PDF)\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/vpl-in001_-en-p.pdf\"\u003eRockwell Kinetix VPL installation, VPL-IN001F (PDF)\u003c\/a\u003e for motor codes and hybrid plugs.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/2198-um001_-en-p.pdf\"\u003eRockwell Kinetix 5500 user manual, 2198-UM001N (PDF)\u003c\/a\u003e for drive wiring, diagnostic screens and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4410411502363-Allen-Bradley-VPL-motor-setup\"\u003eMitchell Allen-Bradley VPL test setup\u003c\/a\u003e for adapter, leads, motor memory and run-test examples.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eAsk SpareFaber about site diagnosis or bench evaluation\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"SpareFaber","offers":[{"title":"Default Title","offer_id":51116567756965,"sku":"SFT3","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/SICK_EKM36_HIPERFACE_DSL_Encoder_Technical_Guide_Service_Visit_for_installation_Signal_Check_Alignment.jpg?v=1794073205","url":"https:\/\/www.sparefaber.com\/ar\/products\/sick-ekm36","provider":"SpareFaber","version":"1.0","type":"link"}