{"product_id":"sick-skm36","title":"SICK SKM36 HIPERFACE Encoder | Technical Guide \u0026 Service |  Book UAE Location Factory Visit- Service\/Align","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eInvestigating a SICK SKM36 feedback fault?\u003c\/strong\u003e SpareFaber can check the encoder, motor feedback harness and drive on site in the UAE. For a motor already removed, ask about bench diagnosis, replacement fitting and verification of the motor-specific commutation setting.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eCompare SKM36 part numbers\u003c\/a\u003e \u003ca href=\"#wiring\"\u003eGo to wiring\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK SKM36 technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eWhat Our Engineer can Test During the Visit with Encoder Testing Equipment, \u003c\/h2\u003e\n\u003cp\u003eChoose an on-site visit when the alarm occurs in the machine or the drive and feedback cable need to be checked together. If the motor or encoder is already out, include the complete SICK part number, motor order code and drive alarm when requesting a bench evaluation. Ask for packing instructions before sending an assembly.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat Our Engineer can Test During the Visit with Encoder Testing Equipment, \u003c\/h2\u003e\n\u003cp\u003eMitchell’s TI-5000JX training manual covers SKM36 under SICK Stegmann HIPERFACE feedback. A matching fixture can check the device identity and status, the absolute position and turn count, and the analog sine\/cosine track. Mitchell documents the TI-5104 adapter for compatible HIPERFACE setups. Select the bench harness and supply for the actual encoder and motor. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26697502947227-SICK-Stegmann-Hiperface-Serial-Encoders\"\u003eMitchell HIPERFACE test guide\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eA serial position that reads correctly confirms one feedback path. A specialist checks the two analog signals separately, especially if the drive alarms while moving. For motors that store a commutation offset in encoder memory, capture the original data using the applicable OEM method before replacement.\u003c\/p\u003e\n\u003ch2\u003eSICK SKM36 technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment and memory\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind the type and part number on your label\u003c\/h2\u003e\n\u003cp\u003eRecord both the SICK type code and the seven-digit part number. The full suffix matters. These examples show how a similar name can identify a different shaft, connection or position range.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Searchable encoder ID comparison\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eSelected SICK SKS\/SKM36 variants\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSICK part no. and type\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eShaft and mounting\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eConnection\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePosition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/5\/55\/955\/dataSheet_SKM36-HFA0-K02_1034094_en.pdf\"\u003e1034094 · SKM36-HFA0-K02\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eTapered shaft, spring mounting plate\u003c\/td\u003e\n\u003ctd\u003e8-pin radial integration connector\u003c\/td\u003e\n\u003ctd\u003eMultiturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1035601 · SKM36-HVA0-K02\u003c\/th\u003e\n\u003ctd\u003e6 mm solid shaft, standalone flange\u003c\/td\u003e\n\u003ctd\u003e8-pin M12 radial connector\u003c\/td\u003e\n\u003ctd\u003eMultiturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1035602 · SKM36-HVV0-K02\u003c\/th\u003e\n\u003ctd\u003e6 mm solid shaft, standalone flange\u003c\/td\u003e\n\u003ctd\u003e1.5 m integral cable\u003c\/td\u003e\n\u003ctd\u003eMultiturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1036558 · SKM36S-HFA0-K02\u003c\/th\u003e\n\u003ctd\u003eTapered shaft, spring mounting plate\u003c\/td\u003e\n\u003ctd\u003e8-pin radial integration connector\u003c\/td\u003e\n\u003ctd\u003eMultiturn safety variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1034095 · SKS36-HFA0-K02\u003c\/th\u003e\n\u003ctd\u003eTapered shaft, spring mounting plate\u003c\/td\u003e\n\u003ctd\u003e8-pin radial integration connector\u003c\/td\u003e\n\u003ctd\u003eSingleturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eSICK publishes a data sheet for standard part \u003cstrong\u003e1034094\u003c\/strong\u003e. Confirm current orderability by full part number. SICK lists the special \u003cstrong\u003eSKM36-HFA0-S02, part 1034601\u003c\/strong\u003e, as no longer sellable. Its service note describes special shielding and screws. Use the motor maker’s approved replacement, especially for a safety variant or an OEM-programmed unit. Checked 7 November 2026. \u003ca href=\"https:\/\/www.sick.com\/media\/familyoverview\/4\/84\/684\/familyOverview_SKS-SKM36_g215684_en.pdf\"\u003eSICK family overview (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.sick.com\/sick-knowledgebase\/article\/?code=KA-10707\"\u003eSICK special variant service note\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications for SKM36-HFA0-K02\u003c\/h2\u003e\n\u003cp\u003eThe values below apply to SICK part \u003cstrong\u003e1034094\u003c\/strong\u003e, the standard tapered-shaft multiturn version.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SICK 1034094 specifications\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSICK SKM36-HFA0-K02 · 1034094\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eManufacturer specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eHIPERFACE with analog sine\/cosine and a serial parameter channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalog scale\u003c\/th\u003e\n\u003ctd\u003e128 sine\/cosine periods per mechanical turn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute position range\u003c\/th\u003e\n\u003ctd\u003e4,096 steps per turn across 4,096 turns, 16,777,216 steps total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSystem accuracy\u003c\/th\u003e\n\u003ctd\u003e±120 arcseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSine\/cosine signal levels\u003c\/th\u003e\n\u003ctd\u003e0.8–1.1 Vpp relative to their references. Reference offsets 2.2–2.8 V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDC supply\u003c\/th\u003e\n\u003ctd\u003e7–12 V at the device. SICK recommends 8 V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent draw\u003c\/th\u003e\n\u003ctd\u003e60 mA without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating speed\u003c\/th\u003e\n\u003ctd\u003eUp to 9,000 rpm for reliable absolute position formation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector\u003c\/th\u003e\n\u003ctd\u003e8-pin radial male connector. See the device-side pin table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−20 to +110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP50 with the mating plug inserted and cover closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/5\/55\/955\/dataSheet_SKM36-HFA0-K02_1034094_en.pdf#page=2\"\u003eSICK data sheet for 1034094, pp. 2–6 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eHow the tapered version mounts\u003c\/h2\u003e\n\u003cp\u003eOn \u003cstrong\u003e1034094\u003c\/strong\u003e, the 1:3 taper locates the encoder shaft concentrically in the motor shaft. The M4 threaded shaft connection retains it. The spring mounting plate attaches to the motor flange at two M3 fixing points and keeps the housing from turning with the shaft. SICK’s drawing shows the mating taper, hole pattern and allowed movement. The solid-shaft versions use their own flange and coupling arrangement.\u003c\/p\u003e\n\u003cp\u003eWith the drive isolated and the load and motor shaft secured, inspect the spring plate, seating and wire routing if the OEM allows access. Use the specified SICK tool and the manufacturer’s mounting procedure for removal, reseating and fasteners. Record the original fit and encoder settings before disturbing the assembly. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/5\/55\/955\/dataSheet_SKM36-HFA0-K02_1034094_en.pdf#page=4\"\u003eDimensional and mating drawings, pp. 4–5 (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/cdn.sick.com\/media\/docs\/1\/41\/241\/operating_instructions_sks_skm36_motor_feedback_system_rotary_hiperface%C2%AE_de_en_im0044241.pdf#page=17\"\u003eSICK tapered-shaft mounting and removal, §3.4 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface · How HIPERFACE supplies position\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring method:\u003c\/strong\u003e absolute multiturn, with incremental analog feedback for motion. The drive reads the encoder’s position and turn count over the bidirectional RS-485 HIPERFACE parameter channel. It can also read device identity, status and stored parameters. At startup the drive uses the absolute position as its reference, then tracks motion between serial reads from the analog sine and cosine signals.\u003c\/p\u003e\n\u003cp\u003eEach analog channel has its own reference, \u003cstrong\u003eSIN to REFSIN\u003c\/strong\u003e and \u003cstrong\u003eCOS to REFCOS\u003c\/strong\u003e. The drive interpolates their phase to estimate position within each of the 128 periods. The analog track and the serial channel can fail separately, so verify both when diagnosing a feedback alarm. \u003ca href=\"https:\/\/cdn.sick.com\/media\/docs\/1\/41\/241\/operating_instructions_sks_skm36_motor_feedback_system_rotary_hiperface%C2%AE_de_en_im0044241.pdf#page=19\"\u003eSICK HIPERFACE interface description, §4.1 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified device-side wiring for 1034094\u003c\/h2\u003e\n\u003cp\u003eUse SICK’s connector view in Figure 5 to identify pin numbers on the 8-pin integration connector. The standalone M12 connector uses the separate Table 2 assignment. Use the motor and drive makers’ drawings for the external harness.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SICK 1034094 integration connector pinout\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSKM36-HFA0-K02 device pins · SICK Table 1\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSignal\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003eU\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003e+SIN\u003c\/td\u003e\n\u003ctd\u003eSine signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eREFSIN\u003c\/td\u003e\n\u003ctd\u003eSine signal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003e+COS\u003c\/td\u003e\n\u003ctd\u003eCosine signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5\u003c\/th\u003e\n\u003ctd\u003eREFCOS\u003c\/td\u003e\n\u003ctd\u003eCosine signal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e6\u003c\/th\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003ctd\u003eSupply return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7\u003c\/th\u003e\n\u003ctd\u003eData+\u003c\/td\u003e\n\u003ctd\u003ePositive serial data line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8\u003c\/th\u003e\n\u003ctd\u003eData−\u003c\/td\u003e\n\u003ctd\u003eNegative serial data line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.sick.com\/media\/docs\/1\/41\/241\/operating_instructions_sks_skm36_motor_feedback_system_rotary_hiperface%C2%AE_de_en_im0044241.pdf#page=19\"\u003eSICK connector views and pin assignments, pp. 19–20 (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"motor-cables\" style=\"scroll-margin-top: 6rem;\"\u003eCables inside the motor\u003c\/h3\u003e\n\u003cp\u003eStart with the encoder end, then match the motor-body connector by the full motor order code. The \u003cstrong\u003eSKM36-HFA0-K02 (1034094)\u003c\/strong\u003e uses the small white 8-pin JST integration lead. M23 describes the connector family. The motor maker specifies the insert, keying, pin assignments, supply and any separate temperature wires.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SKM36 internal lead and motor connector references\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eOrdering references for the encoder lead and motor connector\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eApplies to\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePart number or connector\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to match\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSICK SKS\/SKM36 built-in JST versions\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e2031086\u003c\/strong\u003e · DOL-0J08-G0M2XB6\u003c\/td\u003e\n\u003ctd\u003e200 mm, 8-pin female JST to eight flying leads. SICK lists it as an unshielded lead for installation in the motor. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/9\/69\/269\/dataSheet_DOL-0J08-G0M2XB6_2031086_en.pdf\"\u003eLead data sheet (PDF)\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRockwell MPF models in MP-IN004D\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAEDC227NN00000012000\u003c\/strong\u003e · Intercontec 17-pin M23 feedback connector\u003c\/td\u003e\n\u003ctd\u003eMotor-side connector reference. The drawings use different supply and return pins for the 5 V and 9 V motor groups. Match the original feedback option and supply. \u003ca href=\"https:\/\/configurator.rockwellautomation.com\/api\/Doc\/mp-in004_-en-p.pdf\"\u003eRockwell connector data, pp. 15–16 (PDF)\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSEW CM3C63–100 with AK0H, AK1H or EK1H\u003c\/th\u003e\n\u003ctd\u003eIntercontec 623 series · SEW insert · 12-pin M23 SpeedTec\u003c\/td\u003e\n\u003ctd\u003eMotor-side connector family. Order the harness or connector for the exact motor serial number and use the contact-end view in §5.6.4. \u003ca href=\"https:\/\/media.sew-eurodrive.com\/sew_in\/media\/sew-eurodrive\/sew-ind-pdf\/manuals\/26870517-synchronous-servomotors-cm3c63-100.pdf\"\u003eSEW motor connector drawing (PDF)\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eWhen making or repairing the loom.\u003c\/strong\u003e Use the \u003ca href=\"#wiring\"\u003eSICK device pin table\u003c\/a\u003e and the exact motor-end drawing together. Match the specified contacts, wire gauge, shielding, shell bond and strain relief. With the harness disconnected at both ends and separated from sensors and electronics, check each intended connection and check for shorts to adjacent conductors, shield and shell before reconnecting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBench cable.\u003c\/strong\u003e SICK \u003cstrong\u003e2071327\u003c\/strong\u003e (DSL-2317-G01MJB6) goes from an 8-pin JST to a 17-pin M23 on the PGT-11-S programming setup. Use the motor maker’s harness or drawing for the installed loom. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/6\/46\/746\/dataSheet_DSL-2317-G01MJB6_2071327_en.pdf\"\u003eBench cable data sheet (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sick.com\/media\/docs\/6\/06\/506\/operating_instructions_pgt_11_s_svip_de_en_im0058506.pdf\"\u003eSICK PGT-11-S cable assignments (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eChecks before replacing the encoder\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the plug and mounting.\u003c\/strong\u003e Isolate the drive and all feedback supplies, follow the OEM discharge and verification procedure, and secure the motor and load. Inspect the connector for pushed-back pins, debris or a failed latch. Check the harness strain relief and accessible mounting hardware for movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the isolated harness.\u003c\/strong\u003e Disconnect both ends and separate any sensor or inline electronics. Compare continuity end to end with the wiring diagram. Check for shorts between conductors that should be separate and between signal wires and the shield. A cable shield bonded to a connector shell can be intentional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck supply under load.\u003c\/strong\u003e A qualified technician can use an OEM-approved breakout installed while isolated, then use the approved feedback-only test state with motor motion prevented. Check for 7–12 V DC between device pins 1 and 6 on \u003cstrong\u003e1034094\u003c\/strong\u003e. If the encoder-end voltage is low, compare it with the drive-end supply at the specified test point. Isolate again before removing the breakout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate the two feedback paths.\u003c\/strong\u003e If the drive cannot read the device, check supply and Data+\/Data− continuity first. If identification works but the position or speed fails during motion, check the SIN\/COS channels, their reference wires, shielding and coupling. A known-good compatible harness or a secured bench test helps distinguish a cable or drive fault from a fault inside the encoder.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor applications\u003c\/h2\u003e\n\u003cp\u003eMitchell describes some Allen-Bradley MPL-A1xx motors with OEM feedback tested using the SKM36 selection. Match the motor order code and encoder label before selecting any supply, harness or replacement. Mitchell also documents Rexroth MSK applications with OEM SKS36 or SKM36 S01 feedback. For those builds, Mitchell reports that controller firmware MPx-V20 and later requires the S01 version. Check the controller and feedback option before selecting a replacement. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26697502947227-SICK-Stegmann-Hiperface-Serial-Encoders\"\u003eMitchell HIPERFACE guide\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4404782999707-Rexroth-MSK-support\"\u003eRexroth MSK replacement guidance\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and encoder memory\u003c\/h2\u003e\n\u003cp\u003eFor the Allen-Bradley MPL, MPF and 1326 HIPERFACE builds and Rexroth MSK HIPERFACE builds documented by Mitchell, the stored commutation offset belongs to the individual motor. The tester uses that offset to calculate electrical lockup angles for the motor. Match the motor and drive first, since other applications can use a motor-family reference or hold the offset in the drive.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead and save the original.\u003c\/strong\u003e On the appropriate secured bench fixture, select the actual encoder and motor memory profile. Record the motor model and serial, encoder type, and firmware where available. Confirm the read matches the motor label and that checksums pass. Save the original motor data file and record the derived \u003cstrong\u003e+U\/−V\u003c\/strong\u003e and \u003cstrong\u003e+U\/−W\u003c\/strong\u003e electrical angles when the software reports them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestore the same motor’s data.\u003c\/strong\u003e Use the documented memory program function with a replacement approved for that motor and controller. Keep the original data file as a backup. Follow the OEM procedure for encoder calibration and safety variants. If the original cannot be read reliably, obtain the OEM data or use the motor maker’s commissioning procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the assembled motor.\u003c\/strong\u003e Read back the programmed data, confirm its integrity and compare the recorded electrical targets with the assembled motor on the approved fixture. Verify the feedback direction, pole count and motor-specific alignment before returning the axis to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26705639250203-Allen-Bradley-Reliance-Electrocraft-Motors\"\u003eMitchell Allen-Bradley memory and derived angles\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26687041142427-Rexroth-Motors\"\u003eMitchell Rexroth memory and alignment\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4413153461659-How-to-Extract-and-Program-Memory-Data-on-an-Unsupported-Motor\"\u003eMitchell memory read and program workflow\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/5\/55\/955\/dataSheet_SKM36-HFA0-K02_1034094_en.pdf\"\u003eSICK 1034094 data sheet (PDF)\u003c\/a\u003e for ratings, dimensions, signals and diagnostic status codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.sick.com\/media\/docs\/1\/41\/241\/operating_instructions_sks_skm36_motor_feedback_system_rotary_hiperface%C2%AE_de_en_im0044241.pdf#page=13\"\u003eSICK SKS\/SKM36 operating instructions 8013452 (PDF)\u003c\/a\u003e for installation, removal and wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/familyoverview\/4\/84\/684\/familyOverview_SKS-SKM36_g215684_en.pdf\"\u003eSICK SKS\/SKM36 family overview (PDF)\u003c\/a\u003e to match the full variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"SpareFaber","offers":[{"title":"Default Title","offer_id":51115560992933,"sku":"SGB1","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Sick_SKM36S-HFA0-K02.jpg?v=1794133794","url":"https:\/\/www.sparefaber.com\/ar\/products\/sick-skm36","provider":"SpareFaber","version":"1.0","type":"link"}