{"product_id":"temposonics-rh5sa0375m02d561u101-ethercat","title":"Temposonics RH5SA0375M02D561U101 EtherCAT Rod Position Sensor | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for R-Series V RH5 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Temposonics RH5SA0375M02D561U101 EtherCAT Rod Position Sensor technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse EtherCAT master diagnostics and the manufacturer test procedure. With the hydraulic load secured and the electrical system in the appropriate state, a qualified technician can separate cable, power and magnet faults. Use approved movement tests after assembly.\u003c\/p\u003e\n\u003ch2\u003eTemposonics RH5SA0375M02D561U101 EtherCAT Rod Position Sensor technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eRH5SA0375M02D561U101\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRH5SA0375M02D561U101\u003c\/th\u003e\n\u003ctd\u003eRH5 rod, S standard ¾-16 UNF flange, A standard mechanics, 375 mm stroke. Code 02 specifies two magnets.\u003c\/td\u003e\n\u003ctd\u003eD56 uses two D-coded M12 network sockets and M8 power. Code 1 is the standard system. U101 sends position, velocity and acceleration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRH5 design M\u003c\/th\u003e\n\u003ctd\u003eM18 × 1.5 flange in the manufacturer matrix.\u003c\/td\u003e\n\u003ctd\u003eOrder the electrical and stroke options separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRH5 D58 connection option\u003c\/th\u003e\n\u003ctd\u003ePower lead connector changes.\u003c\/td\u003e\n\u003ctd\u003eD58 uses an A-coded M12 power connector. Use the D58 diagram.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for RH5SA0375M02D561U101\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for RH5SA0375M02D561U101\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStroke\u003c\/th\u003e\n\u003ctd\u003e375 mm measuring stroke. Use the drawing for dead zones and total rod length.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlange\u003c\/th\u003e\n\u003ctd\u003eStandard ¾-16 UNF-3A, S configuration. Check the cylinder port and seal design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor technology\u003c\/th\u003e\n\u003ctd\u003eNon-contact magnetostrictive absolute linear position. For a multi-magnet setup the manual specifies matching magnet types and at least 75 mm between front faces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower and output\u003c\/th\u003e\n\u003ctd\u003eD56 wiring shows 12–30 V DC (±20% as specified in the manual), with independent EtherCAT ports.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.temposonics.com\/docs\/temposonicslibraries\/literature\/rv\/data_sheet_r-seriesv_rh5_ethercat_552055_en.pdf?sfvrsn=4d96cedf_23\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe rod projects into the cylinder and the moving magnet tracks the piston. Isolate the hydraulic energy, relieve stored pressure and mechanically secure the load before opening or loosening components. Compare flange, seal, full rod clearance and magnet position with the exact cylinder and sensor drawings.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe moving magnet marks position along the sensing rod. The device sends absolute displacement to the EtherCAT master. Separate physical link and operational state from the process value, status and scaling. Confirm the device description and selected process mapping in the controller project.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"RH5 EtherCAT D56 connector option\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eRH5 EtherCAT D56 connector option\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConnector\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePin assignment on the sensor\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eM8 power\u003c\/th\u003e\n\u003ctd\u003e1 supply, 3 DC ground, 2 and 4 unconnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eD-coded M12 port 1 or port 2\u003c\/th\u003e\n\u003ctd\u003e1 Tx+, 2 Rx+, 3 Tx−, 4 Rx−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the sensor-face views in Figure 98 of the operation manual. Follow the manufacturer shield and grounding instructions. Use the correct port direction and connector coding.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eSelect separate shielded D-coded M12 Ethernet leads and the D56 M8 power lead. Use the accessory and wiring references in the manufacturer's manual and verify connector gender, length and routing against the cylinder assembly.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEtherCAT will not enter Operational\u003c\/th\u003e\n\u003ctd\u003eCheck both network links, configured topology, device description and power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperational with absent or invalid position\u003c\/th\u003e\n\u003ctd\u003eCheck magnet type, orientation, stroke envelope and the process\/status mapping.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition drops at the end of travel\u003c\/th\u003e\n\u003ctd\u003eCheck the magnet path and available measuring stroke before changing scaling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThe exact number appears as a manufacturer nameplate example. Confirm its fit to the original cylinder and magnet, and match the controller project before treating a different RH5 as a spare.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eEstablish the magnet travel and mechanical reference using the hydraulic machine procedure. Compare reported position with the approved machine datum and verify stroke ends within the measuring range.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.temposonics.com\/docs\/temposonicslibraries\/literature\/rv\/data_sheet_r-seriesv_rh5_ethercat_552055_en.pdf?sfvrsn=4d96cedf_23\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/temposonics.com\/en\/products\/industrial-position-sensors\/r-series-v\/r-series-v-rh5\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/temposonics.com\/docs\/temposonicslibraries\/literature\/rv\/operation_manual_r-seriesv_ethercat_552059_en.pdf\"\u003eR-Series V EtherCAT manual\u003c\/a\u003e. See the example nameplate, installation instructions, EtherCAT diagnostics and Figure 98 D56 wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.temposonics.com\/docs\/temposonicslibraries\/literature\/rv\/data_sheet_r-seriesv_rh5_ethercat_552055_en.pdf?sfvrsn=4d96cedf_23\"\u003eRH5 EtherCAT technical data\u003c\/a\u003e. Use the rod and flange drawings, order matrix and connector options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119296905381,"sku":"TCG90","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/TemposonicsRH5SA0375M02D561U101EtherCATRodPositionSensor.jpg?v=1794162103","url":"https:\/\/www.sparefaber.com\/ar\/products\/temposonics-rh5sa0375m02d561u101-ethercat","provider":"SpareFaber","version":"1.0","type":"link"}