{"product_id":"turck-ri360p0-qr24m0-iolx2-h1141","title":"Turck RI360P0-QR24M0 IO-Link Contactless Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for RI360P0-QR24M0 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Turck RI360P0-QR24M0 IO-Link Contactless Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA qualified test can compare the master process data and diagnostics with measured angle using the correct target and gap. A head-only test without the positioning element leaves the mechanical path unchecked. Mitchell support is unverified for exact ID 1590975.\u003c\/p\u003e\n\u003ch2\u003eTurck RI360P0-QR24M0 IO-Link Contactless Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eRI360P0-QR24M0-IOLX2-H1141\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRI360P0-QR24M0-IOLX2-H1141 \/ 1590975\u003c\/th\u003e\n\u003ctd\u003eSeparate positioning element and stationary QR24 sensor. Match the rotor and reducer to the shaft.\u003c\/td\u003e\n\u003ctd\u003eIO-Link 1.1, 32-bit process data. The head reports singleturn angle and a calculated turn count.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eQR24 incremental output family\u003c\/th\u003e\n\u003ctd\u003eRelated contactless housing concept. Verify position element and bracket.\u003c\/td\u003e\n\u003ctd\u003ePulse output versions use a different receiver. The complete IOLX2 order code identifies the IO-Link variant.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for RI360P0-QR24M0-IOLX2-H1141\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for RI360P0-QR24M0-IOLX2-H1141\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003e81 × 78 × 24 mm. IP68\/IP69K per exact datasheet conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating gap\u003c\/th\u003e\n\u003ctd\u003e1.5 mm nominal spacing. Use the setup tools and LED guidance in the exact datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ connector\u003c\/th\u003e\n\u003ctd\u003e15–30 V DC, \u0026lt;50 mA. M12 × 1 4-pin male connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIO-Link\u003c\/th\u003e\n\u003ctd\u003eV1.1 COM2, 38.4 kbaud. 16-bit angle, 13-bit turns and three diagnostic bits in a 32-bit process value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRotor sizing\u003c\/th\u003e\n\u003ctd\u003eThe separately selected positioning element and reducer determine shaft fit. The datasheet lists common metric and imperial sizes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.turck.de\/datasheet\/_en\/edb_1590975_gbr_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe shaft turns a separate positioning element while the housing remains fixed. Check the exact shaft reducer and mounting bracket in pages 3–5. Set the rotor at the stated spacing with the proper mounting accessory. Check centering and clearance before removing the setup aid. Keep nearby metal or brackets clear of the sensing area as specified.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe sensor couples inductively to its rotating element and converts the measured angle into an IO-Link process word. A compatible master uses the matching IODD to interpret angle, turns and diagnostics. Turck calls it semi-multiturn because turns are counted from zero crossings while powered. If the shaft can move during a power loss, check the turn-count plausibility diagnostic before using its multiturn value.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the exact datasheet wiring diagram on page 1 and the master port diagram. This four-pin male M12 device uses pin 4 for IO-Link C\/Q. Confirm L+ and L− using the numbered diagram before connecting the documented 15–30 V DC supply. Keep any unused contact in the specified state and verify the cable end-to-end mapping.\u003c\/p\u003e\n\u003cp\u003eIn an approved powered diagnostic setup, check that the master recognises the device and the physical port is configured for IO-Link. C\/Q is a communication line. Use IO-Link diagnostics to interpret it.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eChoose a compatible M12 A-coded sensor lead with the female device end and the correct master-port end. Preserve the documented C\/Q path and supply rating. Order by length and installed routing. The position element and reducer order codes in pages 4–5 are mechanical accessories and are selected separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaster detects no device\u003c\/th\u003e\n\u003ctd\u003eVerify the port mode, 15–30 V supply and the pin 4 path. Check the device ID and IODD.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData present but angular position drifts\u003c\/th\u003e\n\u003ctd\u003eInspect rotor restraint, shaft fit and gap. Compare raw angle with the measured shaft angle through a controlled turn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAngle sensible but total turns fail after power loss\u003c\/th\u003e\n\u003ctd\u003eCheck the plausibility bit and whether the shaft moved while unpowered. Re-establish the machine reference using the approved procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse on a shaft or rotary machine axis monitored by a compatible IO-Link master. Check PLC byte ordering and scaling in the IODD and the project's loss-of-position behavior.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet mechanical rotor position and gap, then document the angle zero, count direction and any stored preset. Restore the machine's reference only after validating the diagnostic bits and position through travel. This external encoder does not specify a motor commutation angle.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.turck.de\/datasheet\/_en\/edb_1590975_gbr_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.turck.com\/de\/en\/shop\/sensors\/encoders\/1590975\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.turck.com\/de\/en\/shop\/sensors\/encoders\/1590975\"\u003eExact product downloads\u003c\/a\u003e. Use the matching IODD and accessories for order ID 1590975.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118428061861,"sku":"TCG63","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Turck_RI360P0-QR24M0_IO-Link_Contactless_Encoder.jpg?v=1794133255","url":"https:\/\/www.sparefaber.com\/ar\/products\/turck-ri360p0-qr24m0-iolx2-h1141","provider":"SpareFaber","version":"1.0","type":"link"}