{"product_id":"yaskawa-sgm7j-04a7a2c-sigma-7-feedback","title":"Yaskawa SGM7J SGM7J-04A7A2C Sigma-7 Absolute Servo Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for SGM7J installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Yaskawa SGM7J SGM7J-04A7A2C Sigma-7 Absolute Servo Feedback technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eFeedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell lists support for Sigma-7 serial 24-bit absolute encoders in Athena for TI-5000JX. Confirm the selected feature, exact wiring and allowable read operations. The motor-order evidence does not settle a TI-3000JX run profile.\u003c\/p\u003e\n\u003ch2\u003eYaskawa SGM7J SGM7J-04A7A2C Sigma-7 Absolute Servo Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eSGM7J-04A7A2C\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cp\u003eSGM7J-04A7A2C identifies the complete Yaskawa motor. Its internal encoder model and revision are separate.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSGM7J-04A7A2C\u003c\/th\u003e\n\u003ctd\u003eSigma-7 SGM7J, 400 W class. Match the suffix, shaft and option drawing.\u003c\/td\u003e\n\u003ctd\u003eFeedback option 7 is 24-bit absolute. Record the fitted encoder label separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSGM7J with feedback code 6\u003c\/th\u003e\n\u003ctd\u003eDifferent encoder option in the SGM7J ordering key.\u003c\/td\u003e\n\u003ctd\u003e24-bit batteryless absolute. Check the applicable cable and drive setup separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUTTAI-B24 \/ UTTAH-B24RK21\u003c\/th\u003e\n\u003ctd\u003eSigma-7 feedback examples in Mitchell’s ID table, independent of this motor’s exact fitted encoder.\u003c\/td\u003e\n\u003ctd\u003eUse observed label and readback to establish the actual unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for SGM7J-04A7A2C\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for SGM7J-04A7A2C\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor order code\u003c\/th\u003e\n\u003ctd\u003eSGM7J-04A7A2C. 04 denotes 400 W and A denotes the 200 V motor class.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition feedback\u003c\/th\u003e\n\u003ctd\u003eCode 7 is 24-bit absolute. Code 6 identifies the separate batteryless option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhysical fit\u003c\/th\u003e\n\u003ctd\u003eUse the SGM7J-04A drawing for pilot, shaft and installed options. Encoder mechanical dimensions require the fitted unit’s service documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMachine lead\u003c\/th\u003e\n\u003ctd\u003eYaskawa publishes JZSP-C7PA0D-xx-E for specified toward-load battery\/absolute and incremental arrangements in the SGM7J A5–10 frame group.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.yaskawa.com\/delegate\/getAttachment?cmd=documents\u0026amp;documentId=SIEPS80000136\u0026amp;documentName=sieps80000136j_12_0.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eKeep the motor and encoder tags together. Support the axis independently of the brake and use the Yaskawa motor outline for mounting. Avoid disturbing the encoder reference before recording the axis direction and available service data.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe SERVOPACK obtains position via the Sigma-7 serial encoder channel. Verify the configured absolute or incremental operating mode, along with the actual backup arrangement, before interpreting a restart alarm or exchanging encoder hardware.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the exact Yaskawa encoder cable drawing and the installed SERVOPACK connector map. Identify supply, serial pair, shield and battery circuit only where documented. The 200 V motor class describes the motor power circuit. The feedback supply is a separate circuit.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eJZSP-C7PA0D-xx-E is one documented external cable option for the SGM7J frame range, with the cited outlet direction and battery-capable wiring. Check the connector orientation, length and flex option before ordering.\u003c\/p\u003e\n\u003cp\u003eMitchell lists Sigma-7 serial bench support and cautions that the same encoder model can be wired in different ways. Confirm the fitted internal harness and tester adapter from both ends.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute position lost after power down\u003c\/th\u003e\n\u003ctd\u003eCheck the drive’s mode, alarm and documented backup path. Use the model-specific service procedure before disturbing a battery circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm began with cable replacement\u003c\/th\u003e\n\u003ctd\u003eCompare cable suffix, exit orientation, plug lock and battery wiring against the OEM cable drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor identification reads but motion faults\u003c\/th\u003e\n\u003ctd\u003eVerify drive configuration, feedback direction and encoder reference with the Yaskawa procedure. Record whether the issue started after motor repair.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis guide applies to the named SGM7J order on a compatible Sigma-7 SERVOPACK. Record the exact amplifier model and software, the motor option and the internal encoder label before using a test lead or transfer procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the established axis reference and any authorized encoder or drive records before disassembly. Verify the installed feedback reference and absolute initialization using the Yaskawa motor and SERVOPACK procedure. Mechanical and electrical offsets may be separate.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.yaskawa.com\/delegate\/getAttachment?cmd=documents\u0026amp;documentId=SIEPS80000136\u0026amp;documentName=sieps80000136j_12_0.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Yaskawa Sigma-7 rotary servomotor product manual. Use the SGM7J ordering key, dimensions and encoder cable sections.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.yaskawa.com\/products\/motion\/sigma-7-servo-products\/rotary-servo-motors\/sgm7j\"\u003eManufacturer reference\u003c\/a\u003e. Match the exact order code or the identified motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.yaskawa.com\/delegate\/getAttachment?cmd=documents\u0026amp;documentId=CAD-JZSP-C7PA0D-xx-E\u0026amp;documentName=CAD-JZSP-C7PA0D-xx-E.pdf\"\u003eYaskawa JZSP-C7PA0D-xx-E drawing\u003c\/a\u003e. One scoped external option. Match battery path and exit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/8432774627611-Yaskawa-Serial-Encoder-Identification\"\u003eMitchell Yaskawa serial identification\u003c\/a\u003e. Sigma-7 feedback examples and tester identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26303871972123-Athena-5-1-0-2262-TI-5000JX-5-1-0-13-and-TI-3000JX-5-1-0-19\"\u003eMitchell Athena release scope\u003c\/a\u003e. Sigma-7 serial 24-bit absolute support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51126568485029,"sku":"TCG153","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/yaskawa-sgm7j-04a7a2c-sigma-7-feedback-service-guide.jpg?v=1794221171","url":"https:\/\/www.sparefaber.com\/ar\/products\/yaskawa-sgm7j-04a7a2c-sigma-7-feedback","provider":"SpareFaber","version":"1.0","type":"link"}