{"product_id":"yaskawa-sgmsv-25ada21-feedback-technical-guide","title":"Yaskawa SGMSV-25ADA21 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eYaskawa SGMSV-25ADA21 — 20-bit serial incremental, singleturn. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eYaskawa SGMSV-25ADA21 — motor feedback application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eUTTIH-B20 by Mitchell code D; fitted label to verify\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain model \/ application identifier\u003c\/th\u003e\n\u003ctd\u003eSGMSV-25ADA21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor order scope\u003c\/th\u003e\n\u003ctd\u003eOEM catalogue order, not an inspected unit: SGMSV-25ADA21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003e20-bit serial incremental, singleturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5762 \/ TI-5763 \/ TI-5765 \/ TI-5766 are Sigma-V candidates only; select by the exact motor connector and cable drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eTI-5000JX bench scope for the named Sigma family and 20-bit serial incremental, singleturn. Match the fitted label and enabled software, rotate slowly for count checks and use the exact connection drawing. Distinguish the OEM serial feedback path from any test-display commutation or revolution counter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5762 \/ TI-5763 \/ TI-5765 \/ TI-5766 are Sigma-V candidates only; select by the exact motor connector and cable drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eSelect the exact Yaskawa serial profile manually: Athena ENCODER ID may show ----. Mitchell does not support reading this encoder motor memory; preserve factory keying and use the exact motor\/encoder identity for replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eNo TI-3000JX motor-run support for Yaskawa serial encoders is offered in the current Mitchell testing article. This guide admits TI-5000JX feedback bench evaluation only; no motor-run capability is inferred.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe documented test reference is Yaskawa Serial Encoder Identification — Mitchell SGMSV family and feedback code D; OEM drawing 900-026-226. . Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe linked manufacturer record documents this configuration. Current production, stock and an approved successor for the complete fitted order still require manufacturer confirmation. A historical manual or downloadable CAD drawing does not prove present availability. Match voltage, mounting, shaft, brake, feedback, connector and motor-data requirements before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback technology\u003c\/th\u003e\n\u003ctd\u003e20-bit serial incremental, singleturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact catalogue order\u003c\/th\u003e\n\u003ctd\u003eSGMSV-25ADA21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM drawing number\u003c\/th\u003e\n\u003ctd\u003e900-026-226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor voltage class\u003c\/th\u003e\n\u003ctd\u003e200 V; not the feedback supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback code\u003c\/th\u003e\n\u003ctd\u003eD: 20-bit serial incremental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft \/ brake \/ seal arrangement\u003c\/th\u003e\n\u003ctd\u003eplain shaft; no brake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated motor output\u003c\/th\u003e\n\u003ctd\u003e2.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eService values\u003c\/th\u003e\n\u003ctd\u003eEncoder coupling dimensions, exact pin map and tightening torque require the fitted assembly drawing. No value is inferred from a related motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThis is serial incremental feedback, not a physical ABZ encoder connector. Index\/startup behavior and the tester-generated commutation display must be assessed with the correct 20-bit INC selection. Its test revolution counter does not imply persistent absolute turns.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming shaft datum, pilot, bolt pattern, rear clearance, cable exit and retaining arrangement before removal. Use the exact drawing for tolerances and fastening. Do not infer encoder coupling dimensions or tightening torque from the motor flange size. Inspect looseness, bearing play, debris and moisture before disturbing the feedback attachment. The plain shaft; no brake configuration is material to replacement fit. Compare shaft diameter and end treatment, pilot, bolt pattern, brake-dependent length and rear cable clearance with drawing 900-026-226. \u003c\/p\u003e\n\u003cp\u003eSGMSV-25ADA21 is the exact catalogue configuration identified by OEM drawing 900-026-226. 2.5 kW, 200 V; plain shaft; no brake. Check 20-bit serial incremental startup\/index feedback. The drawing describes a catalogue order, not an inspected customer motor.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eKeep motor power, protective earth, feedback, temperature sensing and any holding brake as separate circuits. Establish contact numbering, keying, gender and whether the drawing shows the mating face or wire side. Do not infer a pin map from a connector shell. The exact OEM drawing and actual connector face must select the test lead. TI-5762 \/ TI-5763 \/ TI-5765 \/ TI-5766 are Sigma-V candidates only; select by the exact motor connector and cable drawing. The drawing document number is not an encoder service part number. Confirm the feedback supply and contact view from the matched cable drawing before connection.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5762 \/ TI-5763 \/ TI-5765 \/ TI-5766 are Sigma-V candidates only; select by the exact motor connector and cable drawing.. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the internal encoder-to-motor loom separately from the external machine cable and test fixture. The internal loom part number is not established by the motor model alone. Obtain the assembly drawing and both connector faces. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation; a Mitchell test lead is not an OEM replacement cable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentify before testing\u003c\/th\u003e\n\u003ctd\u003eSGMSV-25ADA21 is the exact catalogue configuration identified by OEM drawing 900-026-226. 2.5 kW, 200 V; plain shaft; no brake. Check 20-bit serial incremental startup\/index feedback. The drawing describes a catalogue order, not an inspected customer motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault with cable movement\u003c\/th\u003e\n\u003ctd\u003eAfter isolation and disconnection at both ends, inspect flex points, pin engagement, contamination and previous repairs. Compare continuity and unintended shorts with the exact diagram, allowing for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo serial data or unstable position\u003c\/th\u003e\n\u003ctd\u003eConfirm the profile, low-voltage supply at the correct boundary and mating-face pin assignment. Compare the test fixture with the actual motor connector; a plausible connector fit does not prove electrical compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback reads but the drive rejects it\u003c\/th\u003e\n\u003ctd\u003eRecord the original alarm and check exact motor identity, stored data requirements, direction, mechanical attachment and the supported signal paths. A reset is not proof of a compatible replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReplacement dimensions look close\u003c\/th\u003e\n\u003ctd\u003eCompare the exact model, shaft, pilot, brake, seal, cooling and connector options above with the linked drawing before ordering or removing the original assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAthena identity appears blank\u003c\/th\u003e\n\u003ctd\u003eA ---- identity display is expected in the documented support. Select the profile from the fitted motor\/feedback identification; do not claim that Athena read or confirmed the stored motor model.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003ePreserve the original mechanical reference, motor phase convention, direction and readable drive data before disassembly. Use the fitted motor and encoder service procedure for replacement. Communication alone does not prove correct alignment or machine origin. The factory encoder key relationship can be disturbed during repair. Record its position before removal. Mitchell cannot read the stored motor identity in this scope, so a replacement from a different motor model is not established as compatible. \u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eSGMSV · 2.5 kW, 200 V; plain shaft; no brake. Check 20-bit serial incremental startup\/index feedback.. SGMSV-25ADA21 is the exact catalogue configuration identified by OEM drawing 900-026-226. 2.5 kW, 200 V; plain shaft; no brake. Check 20-bit serial incremental startup\/index feedback. The drawing describes a catalogue order, not an inspected customer motor.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.yaskawa.com\/delegate\/getAttachment?cmd=documents\u0026amp;documentId=900-026-226\u0026amp;documentName=900-026-226_SGMSV-25ADA21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eExact OEM outline drawing 900-026-226 — SGMSV-25ADA21\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/8432774627611-Yaskawa-Serial-Encoder-Identification\" target=\"_blank\" rel=\"noopener\"\u003eYaskawa Serial Encoder Identification\u003c\/a\u003e — Mitchell SGMSV family and feedback code D; OEM drawing 900-026-226. \u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/13505685409307-Yaskawa-Serial-Encoder-Testing\" target=\"_blank\" rel=\"noopener\"\u003eYaskawa Serial Encoder Testing\u003c\/a\u003e — Named motor family and feedback option; row locator identifies scope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.yaskawa.com\/delegate\/getAttachment?cmd=documents\u0026amp;documentId=YEA-KAEPS80000042\u0026amp;documentName=YEA-KAEPS80000042L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eYaskawa Sigma-5 Rotary Servomotors, YEA-KAEPS80000042L\u003c\/a\u003e — SGMGV, SGMSV and SGMCS model keys and external dimensions\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.yaskawa.com\/downloads\/search-index\/details?docnum=900-026-226\u0026amp;showType=details\" target=\"_blank\" rel=\"noopener\"\u003eYaskawa SGMSV-25ADA21 dimensional drawing 900-026-226\u003c\/a\u003e — Document title, description, PDF and DXF download; exact motor order\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eObtain the complete fitted motor and encoder labels, exact service ID, internal loom, connector mating-face drawing and approved setup. Match the linked OEM document revision; unverified supply, pins, retention fasteners and alignment values remain open. Yaskawa serial TI-3000JX run and encoder-memory reading remain unsupported in the checked Mitchell article.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a SGMSV-25ADA21 enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eNo TI-3000JX motor-run support for Yaskawa serial encoders is offered in the current Mitchell testing article. This guide admits TI-5000JX feedback bench evaluation only; no motor-run capability is inferred. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"related\"\u003e\u003ch2\u003eRelated technical guides\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/sparefaber.com\/products\/yaskawa-sgmsv-serial-feedback-feedback-technical-guide\" target=\"_blank\" rel=\"noopener\"\u003eTCG566 — Yaskawa SGMSV serial feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51153636098213,"sku":"TCG769","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/yaskawa-sgmsv-25ada21-service-guide.jpg?v=1794380037","url":"https:\/\/www.sparefaber.com\/ar\/products\/yaskawa-sgmsv-25ada21-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}