{"title":"Modular fieldbus interface","description":"\u003cp\u003e\u003cspan\u003eA modular fieldbus interface encoder is \u003c\/span\u003e\u003cmark class=\"HxTRcb\"\u003e\u003c!--qkimaf KWmXoe_j\/HugV6--\u003e\u003c!--cqw1tb KWmXoe_j\/HugV6--\u003ea rotational sensor with a two-part design: a core mechanical encoder base unit and a swappable communication cap\u003c!--TgQPHd|||[]--\u003e\u003c\/mark\u003e. This setup lets you change network protocols—such as CANopen, DeviceNet, or Profibus—by swapping the interface module instead of replacing the entire sensor.\u003c\/p\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eCore Design and Parts\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eEncoder Base Unit:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Measures physical rotation using solid or hollow shafts.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eInterface Cap:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Plugs onto the base to handle specific network protocols.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eQuick Swap:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Changes communication types without rewiring the mechanical mount.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eSupported Network Protocols\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eCANopen:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Standard factory automation network.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eProfibus DP:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e High-speed industrial communication.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eDeviceNet:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Common PLC and controller system.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cul class=\"KsbFXc U6u95\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/ul\u003e\n\u003cdiv class=\"Fsg96\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"otQkpb\" role=\"heading\"\u003eMain Benefits\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eLow Stock Costs:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Keep one base sensor and a few different caps.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eEasy Upgrades:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Switch networks later without mechanical changes.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cspan class=\"iNqyIf\"\u003e\u003cstrong class=\"rQesXe MPyX\"\u003eFast Repairs:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Swap a broken network port without pulling the shaft.\u003c\/span\u003e\u003c\/div\u003e","products":[{"product_id":"baumer-bmsv58k1n24c12-00c0g","title":"Baumer MAGRES  BMSV 58K1N 24C12\/00C0 G base encoder  (no bus cover) Encoder","description":"\u003cp\u003e BMSV 58K1N 24C12\/00C0 G base encoder\u003cbr\u003e (no bus cover)\u003c\/p\u003e\n\u003cp\u003eMagnetic absolute single-turn shaft encoder\u003cbr\u003eBMSV flexible – MAGRES\u003c\/p\u003e\n\u003cp\u003e•     single-turn encoder \/ bus cover        \u003cbr\u003e•     magnetic sensing principle         \u003cbr\u003e•     resolution: 12 bit         \u003cbr\u003e•     \u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003emodular fieldbus system      \u003c\/strong\u003e\u003c\/span\u003e   \u003cbr\u003e•     high resistance against shock and vibration    \u003cbr\u003e•     resolution and zero point programmable    \u003cbr\u003e•     clamping or servo flange    \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003evoltage supply 10 - 30 VDC\u003cbr\u003emax. supply current typ. 100 mA (at 24 VDC)\u003cbr\u003eno load\u003cbr\u003eoutput circuit CANopen, DeviceNet, Profibus-DP,\u003cbr\u003eEtherCAT\u003cbr\u003emax. resolution 12 bit (1 step = 5' 16'')\u003cbr\u003emax. error limit ±1°\u003cbr\u003erepeatability 0,3°\u003cbr\u003epreset value programmable within\u003cbr\u003eresolution range\u003cbr\u003eaddress selectable via rotary switches\u003cbr\u003e(B, D, P) or bus (E)\u003cbr\u003ebaud rate selectable via dip switches (B, D)\u003cbr\u003eor bus (E)\u003cbr\u003edirection of rotation looking at the flange, position\u003cbr\u003ecounts up as the shaft rotates\u003cbr\u003eclockwise (CW), programmable\u003c\/p\u003e\n\u003cp\u003emax. revolutions 12'000 rpm (mechanical)\u003cbr\u003e6'000 rpm (electrical)\u003cbr\u003emoment of inertia\u003cbr\u003eC6 typ. 11,8 x 10-7 kgm2\u003cbr\u003eC0 typ. 17,8 x 10-7 kgm2\u003cbr\u003etorque typ. 2,3 cNm\u003cbr\u003e(3'000 rpm \/ 20 °C)\u003cbr\u003emax. shaft load\u003cbr\u003eC6 axial: 10 N radial: 20 N\u003cbr\u003eC0 axial: 40 N radial: 60 N\u003cbr\u003eproduct life dependening on ambient\u003cbr\u003econditions (typ. 109\u003cbr\u003e revolutions)\u003cbr\u003emax. protection class IP 65\u003cbr\u003ematerial housing: steel\u003cbr\u003ebus cover\/flange: aluminium\u003cbr\u003eweight approx. 480 g\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Baumer","offers":[{"title":"Default Title","offer_id":48121627803813,"sku":"AM769","price":1280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/BaumerBMSV58K1N24C1200C0G_4.jpg?v=1786377234"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/collections\/BaumerBMSV58K1N24C1200C0G_5.jpg?v=1786377840","url":"https:\/\/www.sparefaber.com\/collections\/modular-fieldbus-interface.oembed","provider":"SpareFaber","version":"1.0","type":"link"}