{"product_id":"allen-bradley-1326ab-b720e-21-k7-feedback-technical-guide","title":"Allen-Bradley 1326AB-B720E-21-K7 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eAllen-Bradley 1326AB-B720E-21-K7 — Resolver. This technical service guide helps identify the fitted feedback and prepare a scoped installation, repair or alignment assessment. SpareFaber accepts UAE site-service enquiries and send-in bench evaluation requests after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eOEM documents\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted motor and feedback\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003e1326AB-B720E-21-K7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder-number scope\u003c\/th\u003e\n\u003ctd\u003eFull legacy configuration derived from OEM motor\/type-code\/brake tables.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback interface\u003c\/th\u003e\n\u003ctd\u003eResolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eService scope\u003c\/th\u003e\n\u003ctd\u003eMotor feedback assessment; this listing is not an offer of a stocked replacement motor or encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePhotograph the complete motor label, encoder label, connectors and mounting arrangement. Record the drive model and actual alarm text. The guide identifier describes the selected configuration; the received assembly must still match it, especially after an earlier repair.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: confirm the connection first\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX scope\u003c\/th\u003e\n\u003ctd\u003eGeneric resolver excitation, sine\/cosine response and angular evaluation under the matched connection setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable \/ fixture boundary\u003c\/th\u003e\n\u003ctd\u003eTI-5921 for the matching Allen-Bradley 1326AB 10-pin MS resolver connection; verify the actual connector and wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX run scope\u003c\/th\u003e\n\u003ctd\u003eA motor-run assessment depends on the exact supported selection, successful prior feedback checks, winding data, power fixture and tester current\/voltage limits. Motor size or catalogue speed does not promise full-speed or full-load testing, particularly on these larger frames.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eConfirm the installed software selection, actual feedback option and fixture before applying power. Named family support establishes a route for evaluation, not automatic acceptance of every winding or repaired sensor combination. Record what the test actually covered and any excluded functions.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe linked manufacturer document identifies this catalogue configuration. Current production, availability and any approved successor require confirmation against the complete fitted order. A downloadable manual does not prove present stock. Compare voltage, winding, mounting, shaft, brake, feedback, connector and stored motor-data requirements before accepting a replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSelected motor \/ feedback\u003c\/th\u003e\n\u003ctd\u003e1326AB-B720E-21-K7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepresentative build\u003c\/th\u003e\n\u003ctd\u003e1326AB-B720E-21-K7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback interface\u003c\/th\u003e\n\u003ctd\u003eResolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor voltage class\u003c\/th\u003e\n\u003ctd\u003e460 V class; not feedback supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting dimensions\u003c\/th\u003e\n\u003ctd\u003eB7: Ø180 pilot \/ Ø215 PCD mm; PCD means bolt-circle diameter, not flange width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepresentative brake\u003c\/th\u003e\n\u003ctd\u003e24 V DC holding brake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder-number scope\u003c\/th\u003e\n\u003ctd\u003eFull legacy configuration derived from OEM motor\/type-code\/brake tables.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM evidence\u003c\/th\u003e\n\u003ctd\u003e53; 62,65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration note\u003c\/th\u003e\n\u003ctd\u003ePCD is bolt-circle diameter, not flange width.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe 21 option identifies resolver feedback. Assess excitation and both analogue response channels before interpreting angle or phase. The resolver itself has no HIPERFACE serial identity, retained revolution counter or Allen-Bradley encoder memory to read.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eUse the exact motor drawing for pilot, shaft, mounting holes, brake envelope and connector clearance. Catalogue frame size does not define overall length. The selected mounting dimensions describe pilot and bolt circle separately. K7 or K5 identifies the corresponding holding-brake option; use the correct resolver or high-resolution encoder drawing for the axial envelope.\u003c\/p\u003e\n\u003cp\u003eRecord the shaft datum, coupling position, pilot fit and feedback retention before disassembly. Inspect bearing play, shaft damage, contamination and moisture. Motor flange and shaft dimensions do not define the encoder coupling or its tightening torque. Use the actual assembly drawing for fasteners, retention and sealing, and record any previous modifications.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eMotor voltage class never defines feedback supply or resolver excitation. Verify connector gender, keying and contact view using the matching 1326AB or MP-family map. A direct sensor check bypasses the motor loom and external cable; document that boundary.\u003c\/p\u003e\n\u003cp\u003eSeparate motor power, protective earth, low-voltage feedback and temperature circuits. Verify contact numbering, gender, keying and mating-face versus wire-side view. A connector that mates mechanically does not prove electrical compatibility. Check the permitted sensor supply or resolver excitation from its own documentation; the motor voltage rating is a different quantity.\u003c\/p\u003e\n\u003cp\u003eThe representative configuration includes 24 V DC holding brake. Confirm the actual brake label, separate supply and release condition before movement. A feedback assessment does not certify braking torque or the machine holding arrangement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the internal encoder-to-motor loom separately from the external machine cable and bench fixture. The internal loom part number is not established by the frame or interface alone. Obtain both connector faces, the assembly diagram and the correct contact view. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation. A Mitchell test lead identifies a test connection; it is not an OEM replacement machine cable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks and useful observations\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo feedback communication\u003c\/th\u003e\n\u003ctd\u003eConfirm the exact interface, fixture, supply and contact orientation. Check the selected connection boundary before concluding that the sensor is defective.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition jumps or intermittent alarms\u003c\/th\u003e\n\u003ctd\u003eRecord direction, movement range, cable position and temperature. Compare a stationary cable check with controlled movement where the supported setup permits it.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault after encoder or bearing work\u003c\/th\u003e\n\u003ctd\u003eCompare the incoming memory\/reference record, fitted sensor identity, mechanical retention and phase relationship. A stable position display does not establish correct commutation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBench result differs from the machine\u003c\/th\u003e\n\u003ctd\u003eCheck which loom, connector, drive interface and operating conditions the bench bypassed. Reproduce the actual symptom before recommending a component change.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor motion or holding issue\u003c\/th\u003e\n\u003ctd\u003eThe representative configuration includes 24 V DC holding brake. Confirm the actual brake label, separate supply and release condition before movement. A feedback assessment does not certify braking torque or the machine holding arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eKeep each observation separate from the conclusion. State whether a fault is repeatable, which connection was tested and what changed after cleaning or adjustment. Avoid replacing an encoder solely because the drive reports a feedback alarm; a damaged cable, incorrect parameter or mechanical problem can produce a similar report.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and stored data\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming resolver-to-motor phase relationship and original drive parameters before loosening the sensor. Use the fitted motor procedure and verify phase after reassembly. Do not apply the M2\/S2 encoder-memory workflow to this resolver configuration. Commutation and machine reference remain separate settings.\u003c\/p\u003e\n\u003cp\u003ePreserve original records before any permitted change. An alignment operation concerns the motor\/feedback relationship; machine home, travel limits and process offsets remain separate. Check the fitted procedure and document the measured result after reassembly.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor, drive and replacement matching\u003c\/h2\u003e\n\u003cp\u003eMatch the complete chain: motor order, feedback option, internal loom, motor bulkhead, external cable and drive configuration. Similar frame size, speed or interface wording does not establish interchangeability. Confirm shaft and flange fit, brake requirements, thermal sensor, winding and stored-data requirements before approving a substitute.\u003c\/p\u003e\n\u003cp\u003eA motor-run assessment depends on the exact supported selection, successful prior feedback checks, winding data, power fixture and tester current\/voltage limits. Motor size or catalogue speed does not promise full-speed or full-load testing, particularly on these larger frames.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and supporting evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca target=\"_blank\" rel=\"noopener\" href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26705639250203-Allen-Bradley-Reliance-Electrocraft-Motors\"\u003eMitchell motor-family \/ feedback support\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca target=\"_blank\" rel=\"noopener\" href=\"https:\/\/support.rockwellautomation.com\/ci\/okcsFattach\/get\/59279_5\"\u003eOEM motor documentation: 53; 62,65\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca target=\"_blank\" rel=\"noopener\" href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26578514023963-Generic-Resolvers\"\u003eMitchell generic resolver test procedure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell family-specific test cable index\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource review: 21 November 2026. The linked OEM drawing identifies the stated catalogue\/configuration scope. Confirm the document revision and complete fitted nameplate before extending wiring, replacement or motor-run claims. Legacy OEM manuals may be hosted by an independent document archive.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon service questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIs this a complete replacement order number?\u003c\/summary\u003e\u003cp\u003eFull legacy configuration derived from OEM motor\/type-code\/brake tables.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a good position reading clear the whole axis?\u003c\/summary\u003e\u003cp\u003eNo. Feedback, motor power, drive behaviour, machine cable, holding arrangements and loaded performance are separate evaluation boundaries.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the original encoder be replaced by another with the same interface?\u003c\/summary\u003e\u003cp\u003eOnly after the mechanical fit, electrical connection, exact sensor\/profile, stored data and alignment requirements have been checked for this motor.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat should accompany a service enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear motor and feedback labels, connector photographs, drive model, alarm text and fault history. Describe recent repair work and whether the problem appears at startup, during motion or after warming up.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"assessment-record\"\u003e\u003ch2\u003eWhat the service record should contain\u003c\/h2\u003e\n\u003cp\u003eRecord the received model, serial or service ID, fitted feedback, mechanical condition and original fault before work begins. Include the test profile, connection boundary, fixture and supply\/excitation used. Preserve readable original memory or parameter reports where relevant. Record evidence before and after each adjustment so an intermittent condition is not reported as a confirmed cure without a repeatable check.\u003c\/p\u003e\n\u003cp\u003eThe assessment should distinguish a confirmed defect, a proposed repair and any unresolved condition. State tests that need the machine, a missing drawing or a different fixture. Replacement availability, service timing and the final repair scope are confirmed after inspection.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51263633621157,"sku":"TCG1035","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/tcg1035-1326ab-b720e-service-guide.jpg?v=1795248100","url":"https:\/\/www.sparefaber.com\/de\/products\/allen-bradley-1326ab-b720e-21-k7-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}