{"product_id":"allen-bradley-1326ab-s2l-singleturn-hiperface-feedback-technical-guide","title":"Allen-Bradley 1326AB S2L singleturn HIPERFACE | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eAllen-Bradley 1326AB S2L singleturn HIPERFACE — Classic HIPERFACE singleturn. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eAllen-Bradley 1326AB S2L singleturn HIPERFACE — motor application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eSICK Stegmann HIPERFACE; exact fitted family to verify\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain model \/ application identifier\u003c\/th\u003e\n\u003ctd\u003e1326AB S2L singleturn HIPERFACE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor order \/ source example\u003c\/th\u003e\n\u003ctd\u003eRetain every nameplate suffix; a family example is not a verified fitted motor order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eClassic HIPERFACE singleturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5064 at the documented motor boundary; direct 8-pin uses TI-5069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration distinction\u003c\/th\u003e\n\u003ctd\u003eTCG243 is M2L multiturn and TCG340 is resolver. S2L is the singleturn option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eConditional TI-5000JX feedback scope. Identify S2L, preserve the stored alignment offset and verify feedback after refitting the retaining cover. TI-5104 only with correctly cabled, rating-compatible HIPERFACE fixture. Memory-derived offset, never a universal alignment angle.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5064 at the documented motor boundary; direct 8-pin uses TI-5069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eTI-5104 only with correctly cabled, rating-compatible HIPERFACE fixture. Memory-derived offset, never a universal alignment angle.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eConditional motor-run setup: verify exact motor, fitted feedback, poles, wiring, alignment, lead\/module and installed TI-3000JX profile before running.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe documented test reference is Allen Bradley (Reliance, Electrocraft) Motors — MPS\/MPL\/MPF\/1326AB overview and memory section; OEM feedback-code table. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eCurrent availability, discontinuation and a verified successor for the exact fitted order remain to confirm with the manufacturer. The linked technical documents establish a scoped reference, not stock or drop-in interchangeability. Compare motor, drive, mechanical fit, interface, loom and memory requirements before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback technology\u003c\/th\u003e\n\u003ctd\u003eClassic HIPERFACE singleturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition retention\u003c\/th\u003e\n\u003ctd\u003eSingleturn option: verify within-turn position; no multiturn function is inferred.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMemory\u003c\/th\u003e\n\u003ctd\u003eMotor identity and commutation-offset information must match the fitted motor. No common numerical alignment angle is assigned.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact fit and ratings\u003c\/th\u003e\n\u003ctd\u003eUse the matching manufacturer drawing for supply, connector view, shaft\/coupling, dimensions and fastening. Unknown values remain open.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eClassic HIPERFACE carries serial position\/identity data alongside analogue sine\/cosine feedback. Evaluate both independently. A correct within-turn reading does not confirm multiturn retention, motor data or the analogue signal quality. Match the supply to the exact encoder and connection boundary; this scope does not include HIPERFACE DSL.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming shaft datum, locating seat, coupling, retaining cover, fasteners and cable exit before removal. After isolation, inspect accessible looseness, contamination, rubbing and bearing condition. Use the exact outline and service procedure for engagement, rear clearance and fastening. Preserve the original relationship; do not import a torque or air gap from a similar-looking motor. The 1326AB retaining cover can affect encoder body position; verify alignment after its final installation.\u003c\/p\u003e\n\u003cp\u003eS2L identifies the 1326AB singleturn classic HIPERFACE configuration; M2L multiturn and resolver applications have separate guides. Mitchell notes that removing the rear cover can leave the encoder body free to move. An alignment result obtained with that cover removed therefore needs rechecking after final retention. The matching motor-side connection can permit this final check without reopening the assembly. The stored offset is specific to the motor.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eSeparate the encoder plug, internal motor loom, bulkhead, machine cable and tester fixture. Verify contact numbering, keying, gender and the drawing viewpoint. Identify supply\/return, signal pairs, shield and any independent temperature or brake paths from the exact drawing. No unverified pin map is assigned in this guide.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5064 at the documented motor boundary; direct 8-pin uses TI-5069. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eThe exact fitted internal loom part number has not been verified. Record both ends and obtain the motor assembly drawing. Machine cable choice also depends on receiver, length, shield termination and fixed\/flexing duty. A Mitchell test lead describes a bench connection and is not an OEM replacement cable number.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentify the exact assembly\u003c\/th\u003e\n\u003ctd\u003eS2L identifies the 1326AB singleturn classic HIPERFACE configuration; M2L multiturn and resolver applications have separate guides. Mitchell notes that removing the rear cover can leave the encoder body free to move. An alignment result obtained with that cover removed therefore needs rechecking after final retention. The matching motor-side connection can permit this final check without reopening the assembly. The stored offset is specific to the motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault during cable motion\u003c\/th\u003e\n\u003ctd\u003eAfter isolation and disconnection at both ends, inspect flex points, pin engagement, moisture and repairs. Check continuity and unintended shorts against the exact diagram, accounting for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo signal or communication\u003c\/th\u003e\n\u003ctd\u003eConfirm the encoder option, fixture and supply range. A qualified technician can compare source and load voltage using the approved breakout and manufacturer procedure. Connector shape alone is insufficient.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition reads but the drive rejects feedback\u003c\/th\u003e\n\u003ctd\u003eCheck independent signal paths, motor identity, direction and index\/retention state. Record the original alarm and readable data before settings changes. A reset does not establish correct motor data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial data reads but motion feedback is unstable\u003c\/th\u003e\n\u003ctd\u003eMeasure analogue signal quality with the correct fixture and inspect shaft attachment and harness condition. Keep data-path and track-path findings separate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the original mechanical reference, direction, motor phase convention, retained state and readable data before disturbing the feedback. Use the exact motor procedure for alignment and replacement. Electrical communication alone does not establish the machine origin or a correct motor\/feedback pairing. Allen-Bradley memory carries motor-specific information. Recover the original data where supported, compare it with the motor plate and use the derived offset for that motor. The source’s example angles are not universal. Memory support and writing require the corresponding enabled motor option and compatible replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003e1326AB S2L singleturn HIPERFACE. TCG243 is M2L multiturn and TCG340 is resolver. S2L is the singleturn option.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26705639250203-Allen-Bradley-Reliance-Electrocraft-Motors\" target=\"_blank\" rel=\"noopener\"\u003eAllen Bradley (Reliance, Electrocraft) Motors\u003c\/a\u003e — MPS\/MPL\/MPF\/1326AB overview and memory section; OEM feedback-code table\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/2098-in001_-en-p.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRockwell 2098-IN001: Ultra5000 installation\u003c\/a\u003e — Family-specific motor code, dimensions and connection tables; match fitted revision\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eObtain the complete fitted motor order, encoder label, internal loom drawing, connector contact view and approved fixture. Match the linked family document to the actual order and revision.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a 1326AB S2L singleturn HIPERFACE enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eConditional motor-run setup: verify exact motor, fitted feedback, poles, wiring, alignment, lead\/module and installed TI-3000JX profile before running. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"related\"\u003e\u003ch2\u003eRelated technical guides\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sparefaber.com\/products\/allen-bradley-1326ab-m2l-srm50-srm60-hiperface-feedback\" target=\"_blank\" rel=\"noopener\"\u003eTCG243 — Allen-Bradley 1326AB M2L Stegmann SRM50\/60 Multiturn HIPERFACE Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/sparefaber.com\/products\/allen-bradley-1326ab-standard-resolver-feedback\" target=\"_blank\" rel=\"noopener\"\u003eTCG340 — Allen-Bradley 1326AB Servo Motor Resolver Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51150537818277,"sku":"TCG633","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/allen-bradley-1326ab-s2l-singleturn-hiperface-service-guide.jpg?v=1794370230","url":"https:\/\/www.sparefaber.com\/de\/products\/allen-bradley-1326ab-s2l-singleturn-hiperface-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}