{"product_id":"amci-ht-20-10-geared-resolver","title":"AMCI HT-20-10 Geared Multiturn Resolver Transducer | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for HT-20-10 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"AMCI HT-20-10 Geared Multiturn Resolver Transducer technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eAMCI’s troubleshooting PDF covers checking its receiver, cable and transducer. A qualified technician can compare excitation and the two return paths with the matched AMCI test setup. Confirm any Mitchell resolver fixture, frequency and interface before use. This transducer is an external machine sensor.\u003c\/p\u003e\n\u003ch2\u003eAMCI HT-20-10 Geared Multiturn Resolver Transducer technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eHT-20-10\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHT-20-10\u003c\/th\u003e\n\u003ctd\u003eHT-20-X external transducer with 10:1 mechanical reduction per AMCI.\u003c\/td\u003e\n\u003ctd\u003eGeared single resolver. Match machine travel to the 10-turn scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHT-20\u003c\/th\u003e\n\u003ctd\u003eSeparate single-turn assembly.\u003c\/td\u003e\n\u003ctd\u003eCompare shaft measurement and receiver scaling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHTT-20-X\u003c\/th\u003e\n\u003ctd\u003eSeparate geared dual-resolver series.\u003c\/td\u003e\n\u003ctd\u003eUse its distinct interface and cable drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for HT-20-10\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for HT-20-10\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTravel ratio\u003c\/th\u003e\n\u003ctd\u003e10 input shaft turns per resolver revolution for HT-20-10.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal method\u003c\/th\u003e\n\u003ctd\u003ePassive single resolver, with AC excitation and two angle-dependent returns.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHT-20-X 2–24 turn family values\u003c\/th\u003e\n\u003ctd\u003eAMCI lists 5 kHz excitation, 7.0 V RMS rotor input and 6.65 V RMS stator output under the stated test condition. Use the matched AMCI interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft and connector\u003c\/th\u003e\n\u003ctd\u003e5\/8 inch keyed shaft and MS3102E16S-1P-equivalent device connector per family page.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.amci.com\/files\/9014\/5496\/8718\/ht-20-x-2t162.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe transducer mounts to the machine and couples to its input shaft. Check the shaft key, coupling and bracket alignment and avoid side loads beyond the OEM specification. Inspect for backlash and slip before changing the reported scale. Identify the mechanical travel endpoints before moving the coupling.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe receiver supplies an AC reference and uses two resolver returns to determine angle. Internal gearing maps ten input shaft turns to one resolver cycle. A wrap at the end of that range can be expected in the appropriate setup. A wrap in the middle of travel calls for checking coupling slip, zero and receiver scaling.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eConfirm the connector designation and view using AMCI’s drawing. This table applies to the documented HT-20-X connector. Use the receiver’s own terminal drawing for the other end.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"AMCI HT-20-X device-side circular connector\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eAMCI HT-20-X device-side circular connector\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact or group\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA \/ B\u003c\/th\u003e\n\u003ctd\u003eR1 \/ R2 excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eF \/ G\u003c\/th\u003e\n\u003ctd\u003eS1 \/ S3 pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE \/ C\u003c\/th\u003e\n\u003ctd\u003eS2 \/ S4 pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eD\u003c\/th\u003e\n\u003ctd\u003eUnused per AMCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eAMCI lists mating connector options MS-16 straight, MS-18 right-angle and MS-161 watertight for the stated connector. Select a transducer cable for the exact AMCI input module. Match the excitation and each return pair, shield and the installed cable length. Verify a replacement cable against the interface drawing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver shows loss of transducer\u003c\/th\u003e\n\u003ctd\u003eCheck the approved excitation at the documented test point and trace the disconnected cable to the device.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition jumps under load or on direction change\u003c\/th\u003e\n\u003ctd\u003eInspect key, coupling backlash and bracket. Compare both return channels with the receiver’s expected response.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition wraps early\u003c\/th\u003e\n\u003ctd\u003eCheck the label ratio, mechanical travel, zero and scaling in the AMCI receiver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse this assembly as a machine-position transducer with the matching AMCI resolver input. Confirm the receiver part, configured range and connector. For an external resolver with different gearing or pinout, use its own product documentation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet the machine reference and 10-turn travel range under the equipment commissioning procedure. Check the coupled shaft against known positions and confirm the controller counts in the intended direction. Recheck both ends of travel before returning the axis to operation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.amci.com\/files\/9014\/5496\/8718\/ht-20-x-2t162.pdf\"\u003eMain technical PDF\u003c\/a\u003e. AMCI HT-20-(X) installation drawing. Check the transducer mounting and wiring against the 10-turn configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.amci.com\/plc-automation-products\/ht-20-x-multi-turn-geared-resolver-transducer\"\u003eManufacturer reference\u003c\/a\u003e. Match the exact order code or the identified motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.amci.com\/index.php\/download_file\/1216\/0\/\"\u003eAMCI resolver selection FAQ\u003c\/a\u003e. The HT-20-10 example describes the 10-turn geared device.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.amci.com\/files\/2514\/4831\/4672\/faq-how-to-test-resolver-system.pdf\"\u003eAMCI resolver system troubleshooting PDF\u003c\/a\u003e. Receiver, cable and transducer fault checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.amci.com\/industrial-automation-support\/user-manuals\/\"\u003eAMCI manual index\u003c\/a\u003e. Select HT-20-(X) for the single geared resolver. The HTT series is separate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51125881798821,"sku":"TCG140","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/amci-ht-20-10-geared-resolver-service-guide.jpg?v=1794215872","url":"https:\/\/www.sparefaber.com\/de\/products\/amci-ht-20-10-geared-resolver","provider":"SpareFaber","version":"1.0","type":"link"}