{"product_id":"balluff-bml0apy-ssi-linear-encoder","title":"Balluff BML0APY BML-S1G0-S71D-M5EA-D0-SA42-S284 SSI Linear Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for BML0APY installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Balluff BML0APY BML-S1G0-S71D-M5EA-D0-SA42-S284 SSI Linear Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a compatible SSI master and approved analogue input to check position and both sine\/cosine tracks. Balluff documents the BML Configuration Tool BAE PD-ML-010-04. Verify the exact adapter and any Mitchell profile for this head before hookup.\u003c\/p\u003e\n\u003ch2\u003eBalluff BML0APY BML-S1G0-S71D-M5EA-D0-SA42-S284 SSI Linear Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eBML-S1G0-S71D-M5EA-D0-SA42-S284\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBML-S1G0-S71D-M5EA-D0-SA42-S284 · BML0APY\u003c\/th\u003e\n\u003ctd\u003eLengthwise magnetic head, 16 × 18.5 × 80.3 mm, male 12-pin M12 S284.\u003c\/td\u003e\n\u003ctd\u003eSSI absolute position and analogue sine\/cosine tracks, 1 µm stated resolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBML-S1G0-S71D-M5EG-D0-SA42-S284 · BML0AMW\u003c\/th\u003e\n\u003ctd\u003eSimilar housing and connector, distinct M5EG order. Compare its own manual and tape.\u003c\/td\u003e\n\u003ctd\u003eAlso listed with SSI and sine\/cosine. Check variant configuration and permitted applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eBalluff provides exact records for BML0APY and BML0AMW. Confirm production and availability for the original order code with the manufacturer.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for BML-S1G0-S71D-M5EA-D0-SA42-S284\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for BML-S1G0-S71D-M5EA-D0-SA42-S284\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition and range\u003c\/th\u003e\n\u003ctd\u003e1 µm resolution and 2 m stated measuring range for BML0APY. Verify the ordered tape and application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGap\u003c\/th\u003e\n\u003ctd\u003e0.01–0.8 mm read distance on the exact product record. Use the manual's alignment and tolerance definitions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e4.75–5.25 V DC or 10–28 V DC as specified on the exact record. Verify the installed supply range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003eSSI absolute data and nominal 1 Vpp ±0.35 V analogue sin\/cos. Use the M5EA column.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003e16 × 18.5 × 80.3 mm, M12×1 male 12-pin S284. Ambient −20 to +70 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BML_S1G0_B_S_Q7_M5E___0_S284_X_B22_DOK_894608_AA_000.pdf#page=58\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eInstall the specified magnetic tape parallel to the direction of movement, with the sensor head oriented lengthwise as shown in the manual. Check read distance and angular deviations across the complete travel. Include adhesive and cover thickness when interpreting the gap figure. Dirt, ferrous particles and local tape lifting can affect readings at repeatable points.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe controller clocks absolute position from the SSI data pair. The additional analogue sine and cosine outputs provide an incremental motion path for a controller that uses them. Compare SSI response, analogue amplitudes and motion versus datum independently. A controller can see an absolute frame even when its analogue channels are wired incorrectly.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the S284 plug view on PDF page 57 and table 4-4 on page 58. The male pin-side view and the M5EA analogue column matter. The table here combines the SSI and analogue rows applicable to this order.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"BML0APY S284 device pin assignment\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eBML0APY S284 device pin assignment\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eContact or pair\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ GND\u003c\/th\u003e\n\u003ctd\u003e8 \/ 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSSI clock + \/ −\u003c\/th\u003e\n\u003ctd\u003e3 \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSSI data + \/ −\u003c\/th\u003e\n\u003ctd\u003e6 \/ 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue cosine + \/ −\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue sine + \/ −\u003c\/th\u003e\n\u003ctd\u003e10 \/ 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePreset input\u003c\/th\u003e\n\u003ctd\u003e11, use only as specified by the OEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnused \/ shield\u003c\/th\u003e\n\u003ctd\u003e12 remains free. Screen to connector housing per the manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eVerify the receiver's clock and data polarity and the signal naming convention. A different twelve-pin M12 connector may have another map.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eBalluff's manual section 10.9 lists 12-pin M12 cordsets including \u003cstrong\u003eBCC09MW\u003c\/strong\u003e (2 m) and \u003cstrong\u003eBCC0JCN\u003c\/strong\u003e (5 m). Match the current cordset data, all used contacts, bend duty and supply drop before ordering. Keep any preset circuit protected against unintended operation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo SSI response\u003c\/th\u003e\n\u003ctd\u003eVerify the intended supply at pins 8\/7 and test clock and data pairs separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSSI valid, analogue position noisy\u003c\/th\u003e\n\u003ctd\u003eCheck both sin\/cos pairs at the receiver and compare the head gap and tape condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition jumps near one point\u003c\/th\u003e\n\u003ctd\u003eInspect the tape and mounting at that point. Check the controller's interpretation of error state and data format.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeatable offset after work\u003c\/th\u003e\n\u003ctd\u003eCompare machine datum, orientation and preset history before writing any setting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eBML0APY is a magnetic absolute linear distance or rotary-angle measuring head with matching coded media. This guide covers the cited linear fit. Use the machine's specific tape or ring documentation and verify the exact hardware when comparing BML0AMW.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eEstablish head-to-tape geometry through full travel, then restore the machine datum under the controller's commissioning procedure. Record device settings and the existing datum before using a preset or the Balluff configuration tool. Verify the reference in the approved test state.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BML_S1G0_B_S_Q7_M5E___0_S284_X_B22_DOK_894608_AA_000.pdf#page=58\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.balluff.com\/en-us\/products\/BML0APY\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BML_S1G0_B_S_Q7_M5E___0_S284_X_B22_DOK_894608_AA_000.pdf#page=57\"\u003eBalluff S284 connector face and assignment\u003c\/a\u003e. English section 4.4, table 4-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/assets.balluff.com\/WebBinary1\/MAN_BML_S1G0_B_S_Q7_M5E___0_S284_X_B22_DOK_894608_AA_000.pdf#page=77\"\u003eBalluff mating cable options\u003c\/a\u003e. Section 10.9 lists cable lengths and conductor resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.balluff.com\/en-gb\/products\/BML0AMW\"\u003eExact Balluff BML0AMW record\u003c\/a\u003e. Separate M5EG variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119420211365,"sku":"TCG107","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/balluff-bml0apy-ssi-linear-encoder-service-guide.jpg?v=1794148651","url":"https:\/\/www.sparefaber.com\/de\/products\/balluff-bml0apy-ssi-linear-encoder","provider":"SpareFaber","version":"1.0","type":"link"}