{"product_id":"baumer-eam360-swa-5nc6-14180-a","title":"Baumer EAM360-SWA CANopen Magnetic Multiturn Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for EAM360-SWA installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Baumer EAM360-SWA CANopen Magnetic Multiturn Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a CANopen interface, correct EDS and a secure rotary fixture to observe heartbeat, process data and configuration. Separate a network or controller fault from encoder response with a known-good connection. No exact Mitchell test profile is established here.\u003c\/p\u003e\n\u003ch2\u003eBaumer EAM360-SWA CANopen Magnetic Multiturn Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eEAM360-SWA.5NC6.14180.A\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEAM360-SWA.5NC6.14180.A\u003c\/th\u003e\n\u003ctd\u003eØ36 mm body, Ø10 × 16 mm solid shaft with flat.\u003c\/td\u003e\n\u003ctd\u003eCANopen, 14-bit singleturn, 18-bit multiturn, 5-pin M12.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEAM360-SWA.5LC6.14180.A\u003c\/th\u003e\n\u003ctd\u003eRelated solid-shaft version. Verify the actual drawing.\u003c\/td\u003e\n\u003ctd\u003eCANopen Lift profile. Confirm application and controller support.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEAM360-BDC.5NC6.14180.A\u003c\/th\u003e\n\u003ctd\u003eRelated hollow-shaft construction.\u003c\/td\u003e\n\u003ctd\u003eCANopen variant. Different mechanical arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for EAM360-SWA.5NC6.14180.A\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for EAM360-SWA.5NC6.14180.A\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ connector\u003c\/th\u003e\n\u003ctd\u003e10–30 V DC, 5-pin M12 flange connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition capacity\u003c\/th\u003e\n\u003ctd\u003e16,384 steps\/rev and 262,144 turns.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.15° at +20 ±15 °C. ±0.25° over −40 to +85 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit \/ protection\u003c\/th\u003e\n\u003ctd\u003eØ36 mm flange, Ø10 × 16 mm solid shaft with flat, IP65 without shaft seal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/media.baumer.com\/Baumer_EAM580_360_300_CANopen_MA_EN_Rev0003.0000h_Index0016.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eCheck the flange, locating surfaces and shaft flat in the exact product's drawing. Use a coupling that matches the shaft and keeps application thrust and misalignment within limits. Confirm hub seating and prevent slip on the shaft. Apply only the torque values specified for the actual hardware.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThis magnetic encoder sends absolute angle and turns over CANopen. The PLC or drive uses the exact EDS and device configuration to interpret the process data objects. Configuration and diagnostics are read through CANopen services. Network traffic can be valid while scaling, direction or the preset is wrong.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThis map is the non-redundant CANopen column in the Baumer manual section 14.3 for the single M12 connector. Match the marked contact numbers at the device face and check the mating side of the cable.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Single M12 CANopen contacts\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSingle M12 CANopen contacts\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003eCAN_GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003e+Vs, 10–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eSupply 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003eCAN_H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5\u003c\/th\u003e\n\u003ctd\u003eCAN_L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eFollow the bus diagram for reference ground, shielding and end termination. Use the EDS and CANopen manual for this interface.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eBaumer lists A-coded straight M12 female cable assemblies \u003ca href=\"https:\/\/www.baumer.com\/int\/en\/product-overview\/rotary-encoders-angle-sensors\/industrial-encoders-absolute\/36-mm-integrated\/eam360-sw\/eam360-swa-5nc6-14180-a\/p\/46860\"\u003e11279185, 11279186 and 11279187\u003c\/a\u003e on the exact item page. Check the accessory length, CAN wiring, shield and far-end termination. Match the branch or trunk topology already in the machine.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo heartbeat or PDO\u003c\/th\u003e\n\u003ctd\u003eCheck powered supply, CAN polarity, node ID, bus speed, NMT state and termination before replacing the encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommunicates but value is static\u003c\/th\u003e\n\u003ctd\u003eRead raw position and verify coupling motion, PDO configuration and the PLC tag update.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition differs after replacement\u003c\/th\u003e\n\u003ctd\u003eCheck counts per revolution, total range, direction and position preset against the recorded configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse with a compatible CANopen controller on an industrial rotary axis. The 5LC6 Lift variant calls for its own communication profile and documentation. Verify safety requirements separately using the machine's design.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eBack up the exact device parameters and record the mechanical datum. Restore direction, scaling and preset under the machine commissioning procedure. Confirm stable position after restart. A machine preset and an OEM servo commutation offset are separate settings.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.baumer.com\/Baumer_EAM580_360_300_CANopen_MA_EN_Rev0003.0000h_Index0016.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumer.com\/int\/en\/product-overview\/rotary-encoders-angle-sensors\/industrial-encoders-absolute\/36-mm-integrated\/eam360-sw\/eam360-swa-5nc6-14180-a\/p\/46860\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumer.com\/int\/en\/product-overview\/rotary-encoders-angle-sensors\/industrial-encoders-absolute\/36-mm-integrated\/eam360-sw\/eam360-swa-5nc6-14180-a\/p\/46860\"\u003eExact model downloads\u003c\/a\u003e. Use the exact variant data sheet, mechanical drawing and EDS.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumer.com\/us\/en\/product-overview\/rotary-encoders-angle-sensors\/industrial-encoders-absolute\/36-mm-integrated\/eam360-sw\/eam360-swa-5lc6-14180-a\/p\/46856\"\u003eCANopen Lift comparison\u003c\/a\u003e. Separate 5LC6 variant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumer.com\/us\/en\/product-overview\/rotary-encoders-angle-sensors\/industrial-encoders-absolute\/36-mm-integrated\/eam360-b\/eam360-bdc-5nc6-14180-a\/p\/46868\"\u003eBlind-hollow comparison\u003c\/a\u003e. Separate BDC construction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118429962405,"sku":"TCG64","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/BaumerEAM360-SWACANopenMagneticMultiturnEncoder.jpg?v=1794133129","url":"https:\/\/www.sparefaber.com\/de\/products\/baumer-eam360-swa-5nc6-14180-a","provider":"SpareFaber","version":"1.0","type":"link"}