{"product_id":"baumer-ehog860-e16100012-10","title":"Baumer EHOG860-E16100012\/10 Heavy-Duty HTL-P Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for EHOG860 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Baumer EHOG860-E16100012\/10 Heavy-Duty HTL-P Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eAn approved incremental test input can check A\/B phase, count and index with the correct HTL-P voltage rating and loading. Check the actual Mitchell incremental adapter and input specifications before hookup. Use the drive's documented procedure for any running test.\u003c\/p\u003e\n\u003ch2\u003eBaumer EHOG860-E16100012\/10 Heavy-Duty HTL-P Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eEHOG860-E16100012\/10\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEHOG860-E16100012\/10 · 11736714\u003c\/th\u003e\n\u003ctd\u003e16 mm G7 blind hollow shaft. Retained with a central screw. 1 m cable with open end.\u003c\/td\u003e\n\u003ctd\u003e1,024 pulses per turn, HTL-P line driver, complementary K1\/K2\/K0.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEHOG860-S11100032\u003c\/th\u003e\n\u003ctd\u003eRelated EHOG860 configuration. Match the shaft and exact mechanical drawing.\u003c\/td\u003e\n\u003ctd\u003eConfirm pulse count, output stage and termination from the exact variant sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eBaumer publishes an exact data sheet for article 11736714 dated 4 May 2026. Confirm exact production and availability with Baumer when ordering.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for EHOG860-E16100012\/10\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for EHOG860-E16100012\/10\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft\u003c\/th\u003e\n\u003ctd\u003eØ16 G7 blind hollow shaft, central screw. Size Ø90 mm, length 72 mm in the exact sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e4.75–30 V DC, up to 100 mA without load. Baumer specifies output voltage follows supply for this build.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal\u003c\/th\u003e\n\u003ctd\u003e1,024 pulses\/rev, typically 90° phase shift. K1, K2 and K0 with inverted outputs, HTL-P power line driver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003e1 m factory cable with open end. Use the colour table and overbar notation in the exact PDF.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical speed\u003c\/th\u003e\n\u003ctd\u003eUp to 6,000 rpm mechanical. Respect the separate signal frequency, receiver and installation limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003eIP66 and −40 to +100 °C in the exact-ID sheet. Apply the installation conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/media.baumer.com\/Baumer_EHOG860-E16100012-10_EN_20260504_DS.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe machine shaft engages the 16 mm blind bore and the central screw retains the encoder. The torque support anchors the housing while accommodating the specified motion. Check shaft engagement, seating and support geometry using the drawing and blind hollow-shaft instructions.\u003c\/p\u003e\n\u003cp\u003eInspect the retaining hardware, stator restraint and cable strain only after isolation. Verify the actual fastening hardware and the matching Baumer procedure before loosening or retorquing it.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eK1 and K2 report speed and direction through quadrature. K0 provides the reference pulse. Each track has its own inverse output. A receiver can read a good phase sequence while still missing K0, or can miscount when thresholds and complementary wiring do not match the configured input.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse page 2 of the exact Baumer sheet for the factory one-metre open cable. The paired colours below identify each track. Use the overbars in the original table to confirm the normal and inverted conductors before termination.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Article 11736714 factory cable\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eArticle 11736714 factory cable\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eColour or pair\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ 0 V\u003c\/th\u003e\n\u003ctd\u003eRed \/ blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eK1 pair\u003c\/th\u003e\n\u003ctd\u003eWhite and brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eK2 pair\u003c\/th\u003e\n\u003ctd\u003eGreen and yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eK0 reference pair\u003c\/th\u003e\n\u003ctd\u003eGrey and pink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eKeep the receiver rated for the configured supply-dependent HTL-P output. The field junction is wired from the actual machine diagram.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe named build ends in a fixed one-metre factory lead. Check the exact receiving terminal or junction and select a shielded extension designed for the output, frequency and run length. Match shield and earthing practice to the drive documentation. Baumer's quoted maximum length is conditional on signal frequency and the documented cable arrangement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo pulses or all channels weak\u003c\/th\u003e\n\u003ctd\u003eCheck supply under load and confirm that the input accepts the actual HTL-P level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOne channel intermittently drops\u003c\/th\u003e\n\u003ctd\u003eCheck the factory lead and isolated extension. Compare both sides of the differential pair at the receiver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDirection wrong or reference missing\u003c\/th\u003e\n\u003ctd\u003eCheck K1\/K2 phase order and the K0 pair against the correct output diagram.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault correlates with rotation or load\u003c\/th\u003e\n\u003ctd\u003eCheck the isolated retaining screw and torque support, shaft fit and cable strain.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eBaumer identifies EHOG860 as feedback for demanding machinery and asynchronous drives. The exact build is a speed and incremental position device with a reference pulse. Match the machine's signal configuration and mounting and confirm separately whether it has a safety function.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the mechanical reference and K0 relationship if homing depends on it. After fitting, verify direction and reference capture through the machine's permitted test routine. This incremental feedback configuration uses no servo motor memory restore.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.baumer.com\/Baumer_EHOG860-E16100012-10_EN_20260504_DS.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumer.com\/int\/en\/product-overview\/rotary-encoders-angle-sensors\/heavyduty-encoders-incremental\/hog800-series\/ehog860\/ehog860-e16100012-10\/p\/98944\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.baumer.com\/Baumer_EHOG860-E16100012-10_EN_20260504_DS.pdf#page=2\"\u003eBaumer exact terminal and phase tables\u003c\/a\u003e. Use the overbar notation for polarity.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.baumer.com\/Baumer_EHOG800-Hohlwelle_EN_DE_FR_QS_11730810_V2.pdf\"\u003eEHOG800 blind hollow-shaft quick start\u003c\/a\u003e. Use the drawing and approved instructions for the installed mechanical build.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119407956133,"sku":"TCG104","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/baumer-ehog860-e16100012-10-service-guide.jpg?v=1794148280","url":"https:\/\/www.sparefaber.com\/de\/products\/baumer-ehog860-e16100012-10","provider":"SpareFaber","version":"1.0","type":"link"}