{"product_id":"baumuller-ds2-160ko23i-resolver-technical-guide","title":"Baumüller DS2-160KO23I Resolver A Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eBaumüller DS2-160KO23I\u003c\/strong\u003e with Resolver A is covered in this technical guide. Use it to identify the fitted assembly, compare the documented feedback branches, preserve incoming alignment and readable data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mechanical-fit\"\u003eMechanical fit\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDocuments\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted motor and feedback\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eIdentification item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eScoped information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ grouped base\u003c\/td\u003e\n\u003ctd\u003eBaumüller DS2-160KO23I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTCG1752; SpareFaber service-guide reference, not an OEM part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame \/ family\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue M0 \/ stall reference\u003c\/td\u003e\n\u003ctd\u003e425 Nm; match the selected catalogue row, conditions and complete fitted order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ assembly\u003c\/td\u003e\n\u003ctd\u003eIP23 internally ventilated, integrated axial fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor-data source\u003c\/td\u003e\n\u003ctd\u003eBaumüller 5.23022.01, motor table p.23; standard resolver p.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical source\u003c\/td\u003e\n\u003ctd\u003eActual DS2-160 \/ DS3-160 drawings pp.72–75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoverage boundary\u003c\/td\u003e\n\u003ctd\u003eresolver branch; base identifier omits complete speed\/winding\/shaft\/brake\/factory suffixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePhotograph the complete motor plate, serial, encoder label, feedback connector face and drive nameplate before disturbing the assembly. Record the actual brake, shaft, mounting, cooling, thermal sensor and speed\/winding fields. Standard resolver A is the documented branch grouping used here; it is not a full factory order or an authorization to exchange devices.\u003c\/p\u003e\n\u003cp\u003eStandard A supplies a cyclic resolver angle. Multi-revolution machine reference, controller scaling and motor commutation are application fields rather than a retained absolute encoder turn counter. The resolver-safety branch is separately documented and is not assumed to be installed on this base.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDevice-level test scope:\u003c\/strong\u003e TI-5000JX has resolver test hardware at J12. Use a lead verified for the fitted Baumüller standard A connection and record the actual excitation, resolver speed and signal-pair polarity. TI-3011 is an optional resolver signal breakout. The OEM 7 V RMS at 5 kHz is a specification condition; reconcile RMS\/peak conventions and tester capability before selecting excitation. Do not import Parker's 8 kHz reference or another motor's commutation setup.\u003c\/p\u003e\n\u003cp\u003eRecord the tester hardware, lead\/module, software version, selected feedback type and actual fitted label with the report. First record the incoming fitted-device configuration and relevant position\/signal observations. Preserve supported readable identity and data before any write. A changing count or angle alone does not prove correct mechanical installation, signal quality, commutation sequence or drive configuration.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTest record\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat the observation establishes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabel and setup match\u003c\/td\u003e\n\u003ctd\u003eThe selected device, electrical interface and supply\/excitation match the identified branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlow manual movement\u003c\/td\u003e\n\u003ctd\u003eDirection, continuity, cyclic behaviour and the applicable index\/turn transition can be compared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation and secondaries\u003c\/td\u003e\n\u003ctd\u003eRecord primary excitation, secondary pairs, angle and vector behaviour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndependent signal checks\u003c\/td\u003e\n\u003ctd\u003eVerify sine\/cosine secondary polarity and behaviour through the actual cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBefore\/after report\u003c\/td\u003e\n\u003ctd\u003eIncoming configuration and each approved service change remain traceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eMotor-run scope:\u003c\/strong\u003e TI-5000JX feedback evaluation and TI-3000JX motor-run approval are separate decisions. Establish full motor parameters, pole count, phase convention, fixture\/load, brake handling and speed\/current limits before a run. A supported feedback protocol does not approve a run profile for this complete motor. No universal minimum firmware or exact motor-bulkhead adapter is asserted here.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eMotor data and resolver reference\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOEM standard resolver A\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolver pole pairs\u003c\/td\u003e\n\u003ctd\u003e1 (two poles)\u003c\/td\u003e\n\u003ctd\u003eResolver speed is separate from motor pole count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransformation ratio\u003c\/td\u003e\n\u003ctd\u003e0.5 ±0.05\u003c\/td\u003e\n\u003ctd\u003eAbsolute ratio tolerance, not an invented ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue excitation\u003c\/td\u003e\n\u003ctd\u003e5 kHz, nominal input 7 V RMS\u003c\/td\u003e\n\u003ctd\u003eOEM reference condition; verify actual device and test source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal paths\u003c\/td\u003e\n\u003ctd\u003eExcitation winding and sine\/cosine secondaries\u003c\/td\u003e\n\u003ctd\u003eNot a DC-powered serial encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetained turn count \/ serial memory\u003c\/td\u003e\n\u003ctd\u003eNot supplied by this resolver interface\u003c\/td\u003e\n\u003ctd\u003ePreserve controller offsets and machine reference separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety variant\u003c\/td\u003e\n\u003ctd\u003eSeparate OEM resolver-safety branch\u003c\/td\u003e\n\u003ctd\u003eThis guide scopes standard A, not machine safety validation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe catalogue torque reference for this grouped base is 425 Nm. It is used for identification and priority, not as momentary peak torque or a guaranteed rating for every speed\/winding\/cooling condition. The 425 Nm value is the highest listed M0 among the grouped base's catalogue rows. It is distinct from momentary M0,max and from rated MN at a particular speed; retain actual winding and cooling conditions.\u003c\/p\u003e\n\u003cp\u003eThis is a resolver guide, with no absolute ST\/MT classification. One resolver angle cycle per mechanical turn does not mean that machine multi-turn position or motor alignment is stored in the resolver.\u003c\/p\u003e\n\u003cp\u003eStandard A supplies a cyclic resolver angle. Multi-revolution machine reference, controller scaling and motor commutation are application fields rather than a retained absolute encoder turn counter. The resolver-safety branch is separately documented and is not assumed to be installed on this base.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit, cooling and removal reference\u003c\/h2\u003e\n\u003cp\u003eCatalogue base mass reference: 220 kg. Match the complete shaft, mounting, brake, terminal-box and resolver-holder order. The mass and nominal frame do not establish the whole fitted envelope.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFit item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRecord and compare\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange \/ pilot \/ mounting holes\u003c\/td\u003e\n\u003ctd\u003eUse the exact drawing and mounting version, including connector clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft \/ key \/ coupler\u003c\/td\u003e\n\u003ctd\u003eRecord actual dimensions, insertion depth and machine reference before removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder mounting\u003c\/td\u003e\n\u003ctd\u003eIdentify holder, coupling, fasteners and mechanical reference from the fitted device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake and fan\u003c\/td\u003e\n\u003ctd\u003eIdentify options and added envelope; verify their separate electrical circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeals \/ coolant \/ enclosure\u003c\/td\u003e\n\u003ctd\u003eMatch the actual cooling arrangement and ingress-protection build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eMark the incoming relationship between motor housing, feedback body, shaft and machine reference. Support the assembly without loading the encoder shaft or bearing through an improvised puller. Use the documented removal and assembly method for the fitted device; no unreviewed taper, fastening torque, air gap or insertion force is supplied by this grouped guide.\u003c\/p\u003e\n\u003cp\u003eMechanical drawings to compare: Actual DS2-160 \/ DS3-160 drawings pp.72–75. Connector orientation and holder variants can change practical clearance even where the nominal frame is the same. A similar-looking donor motor does not establish identical shaft, brake or encoder fit.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the standard A resolver diagram on p.50 and the fitted motor\/device connection drawing. Confirm connector view, contact numbering and internal loom before applying excitation. The separate safety-resolver, HIPERFACE and EnDat diagrams do not identify this standard resolver's complete bulkhead route.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCircuit \/ branch\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation primary\u003c\/td\u003e\n\u003ctd\u003eIdentify the actual primary pair and the source's amplitude\/frequency convention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSine secondary\u003c\/td\u003e\n\u003ctd\u003eVerify differential pair, polarity, continuity and response to slow movement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCosine secondary\u003c\/td\u003e\n\u003ctd\u003eKeep the corresponding secondary pair and polarity identified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolver speed\u003c\/td\u003e\n\u003ctd\u003eStandard A has one pole pair; motor electrical angle still needs the actual motor pole count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor connector \/ loom\u003c\/td\u003e\n\u003ctd\u003eUse the p.50 resolver diagram and complete-order bulkhead route, with shield and other circuits kept distinct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eRead connector drawings in their stated contact-side view and verify numbering, keyway, male\/female contacts and shell position. Check continuity with both ends isolated before applying feedback power. Photograph and label any repaired or custom loom so the test report identifies the actual route used.\u003c\/p\u003e\n\u003cp\u003eKeep motor phase conductors, brake supply, fan supply, protective earth, thermal circuits, encoder supply\/return and signal pairs distinct. Do not infer a pinout from wire colour, a shared connector shell, another manufacturer's motor or an electrically different feedback option. If a diagram caption and an order table disagree, resolve the actual fitted branch before energizing it.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eTest leads, internal loom and machine cable\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConnection layer\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat must be established\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect encoder plug\u003c\/td\u003e\n\u003ctd\u003eExact device connector and compatible bench lead; not automatically a motor-bulkhead connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor internal loom\u003c\/td\u003e\n\u003ctd\u003eContinuity, shielding, strain relief and any changes made during earlier repairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor feedback \/ hybrid bulkhead\u003c\/td\u003e\n\u003ctd\u003eCorrect socket, contact view, branch and separate power\/brake\/thermal circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine cable\u003c\/td\u003e\n\u003ctd\u003eBoth endpoint pinouts, length\/routing, drag-chain damage and shield termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive \/ tester end\u003c\/td\u003e\n\u003ctd\u003eCorrect installed selection, supply module and interface-specific lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eA device that reads correctly with a direct plug but fails through the motor can point to the internal loom or bulkhead route. A device that works at the motor but fails through the machine harness requires an endpoint-by-endpoint cable check. Document which layer was bypassed; do not report a complete motor or machine harness as proven from a direct encoder test.\u003c\/p\u003e\n\u003cp\u003eKeep excitation and both secondary pairs identified through each cable layer. Check winding continuity and polarity against the fitted drawing; do not apply a DC encoder-supply assumption to the resolver.\u003c\/p\u003e\n\u003cp\u003eNo complete machine-cable part number or universal lead is assigned to every configuration in this guide. Select or document the cable only after the complete motor\/encoder labels and both connector endpoints are known.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eDiagnostic symptoms and useful comparisons\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eReported symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEvidence to collect before changing parts\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo angle \/ unstable angle\u003c\/td\u003e\n\u003ctd\u003eFitted excitation, primary\/secondary continuity, polarity, resolver speed and lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition changes but drive faults remain\u003c\/td\u003e\n\u003ctd\u003eStatus codes, configuration, motor-data interpretation and phase\/alignment relationship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent or noisy behaviour\u003c\/td\u003e\n\u003ctd\u003eConnector contact, strain\/routing, shield integrity and signal quality through each cable layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncorrect direction or scaling\u003c\/td\u003e\n\u003ctd\u003eRecorded device direction, selected protocol\/word format and drive scaling; do not rewrite offsets to hide it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine reference \/ scaling unexpected\u003c\/td\u003e\n\u003ctd\u003eResolver speed, controller offset, direction and machine multi-revolution reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault appeared after removal\u003c\/td\u003e\n\u003ctd\u003eOriginal reference marks, mechanical holder\/shaft relationship, supported offsets and before\/after reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eCompare one identified path at a time: direct encoder, internal loom, motor bulkhead, then machine cable\/drive. Retain the original symptom, fault codes and setup with each result. An isolated cable fault, an unsupported test selection and a damaged encoder can present a similar initial symptom.\u003c\/p\u003e\n\u003cp\u003eA resolver angle is affected by excitation, winding polarity and resolver speed. Keep resolver speed independent of motor poles, and compare secondary\/vector behaviour before changing a controller offset.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, offsets and memory preservation\u003c\/h2\u003e\n\u003cp\u003eCapture the incoming shaft\/machine reference, device label, drive offsets, direction and the relevant angle\/index\/commutation relationship before removal. Preserve controller configuration and the homing\/reference method with a report identifying the fitted device, fixture, lead and selected test setup.\u003c\/p\u003e\n\u003cp\u003eAfter mechanical work, check the fitted encoder's mounting and signal quality before interpreting an angle. A wrong cable\/selection or an unstable mechanical fit can make an otherwise valid offset appear incorrect. Do not copy an angle, memory image or motor profile from another motor merely because its frame or protocol matches.\u003c\/p\u003e\n\u003cp\u003eThe resolver\/incremental interface does not establish serial encoder memory or a retained multiturn turn counter. Preserve available controller offsets, reference\/homing data and mechanical alignment through the application-specific workflow. Do not apply an absolute-encoder memory image to this device.\u003c\/p\u003e\n\u003cp\u003eIf the original relationship or data is unavailable, define a motor-specific recovery method from documented motor\/feedback information and the installed test system. This guide does not prescribe a universal lock-up angle, firmware threshold, phase convention or replacement memory file. Record the before\/after evidence and the exact change performed.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eService scope, replacement and availability\u003c\/h2\u003e\n\u003cp\u003eThis is a technical-guide\/service listing for Baumüller DS2-160KO23I, not a claim that a complete motor, encoder, brake, fan or cable is held in stock. Parts and service scope follow review of the full fitted labels, connector photos, fault report and required operating conditions.\u003c\/p\u003e\n\u003cp\u003eA replacement decision must compare interface, absolute\/analogue behaviour, supply, mounting, shaft\/holder, connector route, thermal\/brake options, supported motor data and drive compatibility. A motor-base match alone does not establish a drop-in replacement. Catalogue inclusion does not prove current production, exact-order availability, turnaround or certification.\u003c\/p\u003e\n\u003cp\u003eProvide clear label and connector photographs plus the reported symptom and any previous repair changes for a scoped UAE site visit or send-in evaluation. The service quotation can then identify the assessment, repair, alignment or installation work and any parts that require confirmation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eApplications and practical service enquiries\u003c\/h2\u003e\n\u003cp\u003eThe selected 160 frame\/family and 425 Nm catalogue reference place this guide in the identified motor range; they do not rate a new machine duty. Typical enquiries concern feedback faults, connector\/loom repair, motor replacement identification, reinstallation after mechanical work and preservation of existing alignment\/data.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompare the exact motor and feedback branch during a repair intake.\u003c\/li\u003e\n\u003cli\u003eDocument a cable-versus-encoder investigation before replacing an otherwise serviceable assembly.\u003c\/li\u003e\n\u003cli\u003ePrepare an installation or reinstallation visit with complete labels, drive details and machine reference.\u003c\/li\u003e\n\u003cli\u003eAssess an identified replacement against the actual shaft, cooling, brake, connector and data requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse the documents below and the exact fitted-label evidence when comparing another interface or motor base.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest installation, repair or alignment assessment\u003c\/a\u003e and include reference \u003cstrong\u003eTCG1752\u003c\/strong\u003e.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumueller.com\/media\/downloads\/BMN_DS2-100-200_EN_25.pdf\"\u003eBaumüller DS2[3], document 5.23022.01, status 11\/2025\u003c\/a\u003e. Baumüller 5.23022.01, motor table p.23; standard resolver p.50. Mechanical reference: Actual DS2-160 \/ DS3-160 drawings pp.72–75.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26578514023963-Generic-Resolvers\"\u003eMitchell generic resolver hardware and test scope\u003c\/a\u003e. Verify the actual fitted device, excitation source and motor-specific lead.\u003c\/li\u003e\n\u003cli\u003eMotor data p.23; standard resolver p.50; resolver-safety option separately p.51. Use actual DS2-160\/DS3-160 drawing pages 72–75. Old contents-page references can have different offsets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese references support the scoped family and documented options. The complete fitted order and actual device revision determine the final wiring, envelope, software selection and service method. Keep the source edition\/page, nameplate photos and measured setup with the report so a later technician can reproduce the identification.\u003c\/p\u003e\n\u003cp\u003eThe cover is a branded service illustration with concise headings. It is not an OEM dimensional drawing or proof of the exact motor\/encoder installed in a machine.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a complete factory motor order?\u003c\/h3\u003e\n\u003cp\u003eNo. Baumüller DS2-160KO23I is a guide grouping. Match all winding\/speed, shaft, mounting, cooling, brake, feedback and custom-order fields on the actual plates.\u003c\/p\u003e\n\u003ch3\u003eDoes this resolver retain a multiturn position?\u003c\/h3\u003e\n\u003cp\u003eThe resolver supplies angle within its electrical cycle. Controller offsets and machine multi-revolution reference are separate application data.\u003c\/p\u003e\n\u003ch3\u003eCan I use another motor's cable or test selection?\u003c\/h3\u003e\n\u003cp\u003eOnly after the actual device, supply, complete endpoint wiring and installed support are established. A shared shell, frame or protocol name is not enough.\u003c\/p\u003e\n\u003ch3\u003eDoes feedback testing prove a motor-run setup?\u003c\/h3\u003e\n\u003cp\u003eNo. Exact motor parameters, fixture\/load, brake and phase\/alignment conventions require their own motor-specific run-test approval.\u003c\/p\u003e\n\u003ch3\u003eCan the original alignment and data be preserved?\u003c\/h3\u003e\n\u003cp\u003eCapture available incoming identity, mechanical reference, supported angles\/offsets and readable data before removal or writes. Recovery after missing data requires a defined motor-specific method.\u003c\/p\u003e\n\u003ch3\u003eHow do I request service?\u003c\/h3\u003e\n\u003cp\u003eSend full motor and encoder labels, connector photographs, drive details, fault symptoms and previous repair changes with TCG1752. Installation, repair, alignment and site\/send-in scope follow identification.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eSend a service enquiry for TCG1752\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e","brand":"Baumüller","offers":[{"title":"Default Title","offer_id":51298383560869,"sku":"TCG1752","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/baumuller-ds2-160ko23i-resolver-technical-guide-cover.jpg?v=1795461796","url":"https:\/\/www.sparefaber.com\/de\/products\/baumuller-ds2-160ko23i-resolver-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}