{"product_id":"baumuller-ds2-160lo54a-r-heidenhain-endat-singleturn-multiturn-feedback-technical-guide","title":"Baumüller DS2-160LO54A\/R Heidenhain EnDat Singleturn \/ Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eBaumüller DS2-160LO54A\/R\u003c\/strong\u003e with documented Heidenhain EnDat singleturn or multiturn feedback is covered in this combined configuration guide. Identify the fitted device, compare the singleturn\/multiturn branches, preserve incoming alignment and readable motor data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting scope\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eST\/MT comparison\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted configuration\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ grouped motor base\u003c\/td\u003e\n\u003ctd\u003eBaumüller DS2-160LO54A\/R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003e160; compare the actual mounting\/envelope drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing \/ cooling\u003c\/td\u003e\n\u003ctd\u003eIP54 surface-cooled, standard axial\/radial fan alternatives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback coverage\u003c\/td\u003e\n\u003ctd\u003eF\/G — ECN1313\/EQN1325, EnDat 2.1; H\/I — ECN1325\/EQN1337, EnDat 2.2; Y\/X — ECI1319\/EQI1331, EnDat 2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentifier boundary\u003c\/td\u003e\n\u003ctd\u003eGrouped motor base and documented feedback choices, not a complete OEM motor order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService reference\u003c\/td\u003e\n\u003ctd\u003eTCG1558 — SpareFaber reference, not an OEM part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eRead the complete motor type, serial, speed\/winding fields, actual A or R fan selection, mounting, shaft and brake order. Record the fitted encoder model, suffix, serial, interface marking, connector photos and drive model. The shared guide keeps ST and MT information together; it does not authorize exchanging devices or transferring another motor's parameters.\u003c\/p\u003e\n\u003cp\u003eHeidenhain is the manufacturer name; the interface, version and complete encoder marking determine the connection and software selection. The same encoder family name can appear in SSI or other custom formats: follow the fitted interface and this OEM order, not the name alone.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX scope:\u003c\/strong\u003e choose the exact fitted Heidenhain device and supported protocol in the installed software. Confirm current device support before connection; a general EnDat reference does not establish support, memory decoding or firmware requirements for every suffix.\u003c\/p\u003e\n\u003cp\u003eFor devices exposing 1 V peak-to-peak analogue channels, Mitchell describes the TI-5101 interface for the analogue path. Serial-only inductive branches and the shown nine-contact EnDat 2.2 connector must not be treated as the 17-contact EnDat 2.1\/analogue arrangement. No universal direct lead or DS2\/DS3 motor adapter is assigned here.\u003c\/p\u003e\n\u003cp\u003eRecord the test equipment, lead\/module, selected device, installed software version and fitted encoder label with the report. A changing serial count alone does not prove clean analogue signals, correct installation, preserved commutation or a valid motor-data interpretation. No exact minimum firmware version is asserted for this complete assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMotor-run scope:\u003c\/strong\u003e feedback testing and TI-3000JX motor-run approval are separate decisions. Confirm the complete motor parameters, pole count, phase convention, current\/speed limits, load, fixture, brake and installed motor profile before a run test. Do not reuse a DSD2, another DS2 frame or another manufacturer's run profile just because the feedback protocol matches.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSignals, motor data and singleturn\/multiturn comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMotor parameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCatalogue value \/ boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrouped base\u003c\/td\u003e\n\u003ctd\u003eDS2-160LO54A\/R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue M0\u003c\/td\u003e\n\u003ctd\u003eUp to 480 Nm in the grouped-base rows on p.24; match the selected speed\/winding row and conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue motor mass\u003c\/td\u003e\n\u003ctd\u003e285 kg reference base mass; exact fitted options and brake change the assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ protection\u003c\/td\u003e\n\u003ctd\u003eIP54 surface-cooled, standard axial\/radial fan alternatives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated torque MN and momentary M0,max\u003c\/td\u003e\n\u003ctd\u003eSeparate catalogue quantities; neither is interchangeable with the M0 priority value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete speed \/ winding \/ supply order\u003c\/td\u003e\n\u003ctd\u003eNot assigned by the abbreviated base identifier; verify the full nameplate and drive data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding brake\u003c\/td\u003e\n\u003ctd\u003ePresence, module, supply and rating depend on the complete brake order; identify before release or service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFitted EnDat branch\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSingleturn \/ multiturn choices\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSerial positions \/ revolution\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAnalogue boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnDat 2.1 optical\u003c\/td\u003e\n\u003ctd\u003eF \/ ECN1313; G \/ EQN1325\u003c\/td\u003e\n\u003ctd\u003e8,192 (13 bits)\u003c\/td\u003e\n\u003ctd\u003e2,048 sine\/cosine periods; use the 17-contact OEM connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnDat 2.2 optical\u003c\/td\u003e\n\u003ctd\u003eH \/ ECN1325; I \/ EQN1337\u003c\/td\u003e\n\u003ctd\u003e33,554,432 (25 bits)\u003c\/td\u003e\n\u003ctd\u003eOEM table lists 2,048 periods; the shown 9-contact pinout does not route analogue A\/B pairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnDat 2.2 inductive\u003c\/td\u003e\n\u003ctd\u003eY \/ ECI1319; X \/ EQI1331\u003c\/td\u003e\n\u003ctd\u003e524,288 (19 bits)\u003c\/td\u003e\n\u003ctd\u003eNo analogue periods listed in this OEM branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe scoped OEM tables give 3.6–14 V for these EnDat branches; verify the actual suffix\/label and supply path. Each listed multiturn branch reports a 4,096-revolution range. Singleturn EC devices retain the absolute position within one revolution; machine-level referencing beyond it is a separate control function.\u003c\/p\u003e\n\u003cp\u003eSerial absolute positions, analogue periods, multiturn range and controller-scaled counts are different quantities. A period count is not a presumed drive resolution. Motor\/drive supply, feedback supply, fan supply and brake supply are separate circuits. Catalogue motor ratings depend on the selected complete order and cooling conditions, not the encoder's own maximum speed.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit, cooling and retention\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDS2-160LO54A\/R\u003c\/strong\u003e belongs to the frame-160 group. Its reviewed catalogue reference reaches 480 Nm M0 and lists a 285 kg base mass. Use the dimensional sheets on pp.69–71 with the complete ordered build; frame size and base mass do not supply a verified encoder mounting dimension.\u003c\/p\u003e\n\u003cp\u003eThe A\/R surface-cooled alternatives share an electrical-data table, but have different fan and rear-access arrangements. Select the correct A or R dimensional drawing for the fitted complete motor order.\u003c\/p\u003e\n\u003cp\u003eThe abbreviated guide grouping omits speed\/winding, complete mounting and shaft selections and special-order suffixes. Confirm all of them before comparing the motor envelope or ordering a component.\u003c\/p\u003e\n\u003cp\u003eThe OEM dimensional sheet describes the motor envelope, mounting and shaft arrangement. It does not by itself establish the encoder taper, locating seat, coupling fastener torque, permitted air gap or every internal loom. Record the incoming shaft reference, locating\/coupling arrangement, anti-rotation support, fastener positions and cable route before loosening retention.\u003c\/p\u003e\n\u003cp\u003eUse the appropriate handling and support arrangement for the actual assembly mass. Match brake extension, fan\/cooling clearance and connector access against the exact drawing. Retain or obtain the motor\/encoder assembly information needed for refitting and alignment rather than borrowing values from a visually similar motor.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eUse separate connection subcases for the fitted EnDat branch. The OEM shows a 17-contact connection for F\/G EnDat 2.1 on p.55 and nine-contact connections for the listed EnDat 2.2 branches on pp.56\/58. Shared guide coverage does not make these plugs or pin numbers interchangeable.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eEnDat 2.1 signal group\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOEM 17-contact connection, p.55\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock pair\u003c\/td\u003e\n\u003ctd\u003e8 \/ 9 — Clock \/ inverted Clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData pair\u003c\/td\u003e\n\u003ctd\u003e14 \/ 17 — Data \/ inverted Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue A pair\u003c\/td\u003e\n\u003ctd\u003e15 \/ 16 — A+ \/ A−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue B pair\u003c\/td\u003e\n\u003ctd\u003e12 \/ 13 — B+ \/ B−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply \/ return \/ sense\u003c\/td\u003e\n\u003ctd\u003eMatch all remaining supply\/return and any sense wiring to the full OEM and fitted cable drawing; do not infer bridges from repeated labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eEnDat 2.2 motor contact\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOEM nine-contact connection, pp.56\/58\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003ctd\u003eClock \/ inverted Clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 \/ 4\u003c\/td\u003e\n\u003ctd\u003eUp \/ 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 \/ 6\u003c\/td\u003e\n\u003ctd\u003eData \/ inverted Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7 \/ 8\u003c\/td\u003e\n\u003ctd\u003eSensor Up \/ Sensor 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eNot assigned in the shown diagram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe optical EnDat 2.2 table includes an analogue-period specification, but its shown nine-contact motor socket has clock\/data, supply and sense contacts only. Do not invent external analogue channels on that plug. The Y\/X inductive branch has its own serial-only signal scope. Use the complete fitted encoder label and connection drawing together.\u003c\/p\u003e\n\u003cp\u003eKeep the original shielding, connector shell\/earth convention, contact orientation and both-end cable information with the record. A protocol name is not a pinout. Disconnect both cable ends and account for intended shield bonds when performing isolated continuity\/short checks. No assignment on this page is an instruction to wire directly to an unidentified Mitchell test terminal.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eInternal, machine and test cables\u003c\/h2\u003e\n\u003cp\u003eTreat the internal encoder loom, direct-to-encoder bench lead, motor-bulkhead adapter, machine extension and drive-end cable as separate interfaces. Record both-end connector photos, pin views, keying, cable labels, required length, routing and any shield\/sense terminations before selecting a replacement.\u003c\/p\u003e\n\u003cp\u003eChoose the cable\/module and installed software selection for the actual EnDat version and encoder suffix. The 17-contact optical\/analogue and nine-contact serial\/sense branches need their respective drawings; neither the connector body nor a generic Heidenhain label proves a compatible lead.\u003c\/p\u003e\n\u003cp\u003eThe OEM cable chapters for b maXX 4000 and b maXX 5000 describe manufacturer cable\/order contexts. Read the selected encoder, drive end, connector revision and length together; an OEM machine cable is not automatically a Mitchell test adapter. Retain the actual cable drawing in the service file and confirm any adaptation with the applicable supplier information.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cp\u003eBefore physical checks, secure the driven load, isolate and lock out relevant energy sources, observe the specified discharge time and have a qualified technician verify isolation. Powered measurements, rotation, brake release and alignment require the applicable specialist procedure and an identified setup.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eUseful next check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo serial data or intermittent communication\u003c\/td\u003e\n\u003ctd\u003eConfirm the actual device\/interface and installed selection, verified feedback supply and the correct serial pairs. Separate a cable\/connector fault from a device fault using the identified setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute position changes but analogue signals are weak\/noisy\u003c\/td\u003e\n\u003ctd\u003eWhere analogue outputs are documented and accessible, evaluate amplitude\/quality separately and inspect shielding\/contamination\/cable condition. A serial-position pass does not clear the analogue path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirection, scale or commutation differs after service\u003c\/td\u003e\n\u003ctd\u003eCompare the full feedback choice, drive scaling\/direction, motor pole\/phase convention, saved parameters and incoming mechanical reference. Do not transfer another motor's offset.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiturn value disagrees with the machine reference\u003c\/td\u003e\n\u003ctd\u003ePreserve the incoming turn count and shaft history, then compare the machine reference and supported data under the approved procedure. A turn discrepancy is not proof of a battery fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault follows cable movement\u003c\/td\u003e\n\u003ctd\u003eWith isolation verified, check strain relief, connector seating, pin retention, moisture and both-end continuity against the actual drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor run\/brake\/fan fault despite a feedback pass\u003c\/td\u003e\n\u003ctd\u003eReview the separately approved motor-run setup, load and brake state, fan\/cooling operation and power connections. Feedback evaluation does not prove those systems are correct.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eIncoming alignment, offsets and memory\u003c\/h2\u003e\n\u003cp\u003eBefore loosening, removing, resetting or programming feedback, record the incoming mechanical reference, supported commutation\/alignment indication, motor pole count, direction and phase convention. Save the drive offsets and parameters and readable encoder identity, memory\/status and offset data. Tie all records to the motor\/encoder serials and the exact test setup.\u003c\/p\u003e\n\u003cp\u003eRetain or reproduce a valid incoming alignment under the applicable specialist method, then verify it after refitting. A retained memory image alone does not prove correct physical alignment. Where motor-specific memory decoding is unavailable, preserve readable data without presenting a raw backup as a verified commutation value.\u003c\/p\u003e\n\u003cp\u003eFor a singleturn device, retain the within-revolution reference and distinguish it from machine-level multi-revolution referencing. For a multiturn device, additionally preserve and assess the incoming revolution count against shaft history and machine reference. The shared guide does not remove that difference.\u003c\/p\u003e\n\u003cp\u003eIf the feedback was already disturbed, the incoming reference is invalid, or data is absent, corrupt or unreadable, record that limitation and obtain the motor-specific recovery method. No universal angle, automatic recovery or default data transfer from a similar motor is established here. Confirm the full hardware and data format before a memory write.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eBaumüller document 5.23022.01, status 11\/2025, documents the grouped motor and listed feedback choices. Catalogue inclusion is not proof of current stock, production status of every full order, or a drop-in encoder\/motor successor.\u003c\/p\u003e\n\u003cp\u003eCheck the complete motor order\/serial, fitted encoder suffix, hardware revision and applicable current drawing with the supplier before ordering. The service listing is for identification and a scoped technical evaluation; parts, repair extent and turnaround follow review of the fitted assembly and fault. A\/R, I and W layouts and DS2\/DS3 designations must remain correctly identified.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor applications and related feedback coverage\u003c\/h2\u003e\n\u003cp\u003eThis guide concerns the large-frame DS2-160LO54A\/R group and its Heidenhain EnDat feedback choices. It is useful when separating an encoder\/lead\/setup problem from a motor, brake, fan\/cooling or drive issue in the fitted machine. Match the complete machine requirements and ordered motor before selecting a replacement or test procedure.\u003c\/p\u003e\n\u003cp\u003eThe F\/G optical EnDat 2.1, H\/I optical EnDat 2.2 and Y\/X inductive EnDat 2.2 branches share this guide but retain separate device, connection and resolution tables. A general Heidenhain name is not an interface or replacement approval.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/de\/products\/baumuller-ds2-160lo54a-r-hiperface-srs50-srm50-feedback-technical-guide\"\u003eRelated DS2-160LO54A\/R classic HIPERFACE guide\u003c\/a\u003e — additional interface-family identification context, not a substitution approval.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings and primary documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumueller.com\/media\/downloads\/BMN_DS2-100-200_EN_25.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBaumüller DS2[3]-100–200 technical documentation, 5.23022.01, 11\/2025\u003c\/a\u003e — p.11 motor-data definitions; pp.12–13 type code; p.24 selected motor data; pp.69–71 dimensional sheets.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumueller.com\/media\/downloads\/BMN_DS2-100-200_EN_25.pdf#page=55\" target=\"_blank\" rel=\"noopener\"\u003eOEM EnDat 2.1 optical feedback and 17-contact connection, p.55\u003c\/a\u003e; EnDat 2.2 inductive p.56 and optical p.58 in the same document.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumueller.com\/media\/downloads\/BMN_DS2-100-200_EN_25.pdf#page=60\" target=\"_blank\" rel=\"noopener\"\u003eOEM cable chapters, pp.60–65\u003c\/a\u003e — b maXX drive\/cable ordering context; match the actual interface and drive.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumueller.com\/en\/products\/motors\/main-drives\/ds2\" target=\"_blank\" rel=\"noopener\"\u003eBaumüller DS2 manufacturer family page\u003c\/a\u003e — family reference, not exact-order stock confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26653326767387-Heidenhain-Serial-Encoders\" target=\"_blank\" rel=\"noopener\"\u003eMitchell: Heidenhain Serial Encoders\u003c\/a\u003e — fitted device identification, serial\/analogue testing and supported software boundaries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExact application evidence:\u003c\/strong\u003e Motor base DS2-160LO54A\/R: OEM p.24; frame\/cooling and full-order fields pp.12–13; dimensional sheets pp.69–71; F\/G EnDat 2.1 p.55, Y\/X inductive EnDat 2.2 p.56, H\/I optical EnDat 2.2 p.58. Source scope reviewed 23 November 2026.\u003c\/p\u003e\n\u003cp\u003eUse the revision, complete fitted labels and actual connector drawing together. Retain a mismatch for investigation rather than selecting a pinout, replacement or test profile by appearance.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFAQ and service enquiry\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhy are singleturn and multiturn covered together?\u003c\/summary\u003e\u003cp\u003eThey share this motor-base\/interface-family guide, with their position, revolution, connection and data differences compared inside the page. Shared coverage is not an interchangeability approval.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes the short motor-base identifier specify a complete order?\u003c\/summary\u003e\u003cp\u003eNo. Confirm the complete speed\/winding, cooling, mounting, shaft, brake, feedback and special-build fields plus both serial labels before planning work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the feedback be evaluated without a verified motor-run profile?\u003c\/summary\u003e\u003cp\u003eDevice-level evaluation can be scoped after positive identification, connection\/supply checks and confirmation of the installed tester selection. A motor run remains a separate setup and approval.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat if the original alignment or memory is missing?\u003c\/summary\u003e\u003cp\u003eRecord the limitation, retain all readable incoming information and obtain the motor-specific recovery method. A default angle or another motor's data is not a verified recovery.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information should accompany the service enquiry?\u003c\/summary\u003e\u003cp\u003eProvide complete motor\/encoder labels, drive model, connector and cable photos, alarm text, fault timing, service history and any saved incoming alignment\/parameter\/data records. Include the actual fan\/cooling and brake build.\u003c\/p\u003e\u003c\/details\u003e\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or send-in evaluation\u003c\/a\u003e. The scope, parts and turnaround are confirmed after reviewing the fitted configuration and fault.\u003c\/p\u003e\u003c\/section\u003e","brand":"Baumüller","offers":[{"title":"Default Title","offer_id":51293280207013,"sku":"TCG1558","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/baumuller-ds2-160lo54a-r-heidenhain-endat-singleturn-multiturn-feedback-technical-guide-information-poster.jpg?v=1795415758","url":"https:\/\/www.sparefaber.com\/de\/products\/baumuller-ds2-160lo54a-r-heidenhain-endat-singleturn-multiturn-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}