{"product_id":"beckhoff-am305x-am307x-eqn1325-feedback-technical-guide","title":"Beckhoff AM305x–AM307x EQN1325 | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eBeckhoff AM305x–AM307x EQN1325 — Optical EnDat multiturn. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eBeckhoff AM305x–AM307x EQN1325 — Motor application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eEQN1325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMPN \/ full suffix\u003c\/th\u003e\n\u003ctd\u003eEQN1325 is the scoped designation. Retain all additional order characters and manufacturer IDs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM service ID \/ motor order\u003c\/th\u003e\n\u003ctd\u003eExact fitted-unit service number and motor order are not established; record them separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eOptical EnDat multiturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5083 on the verified 17-contact EnDat connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration distinction\u003c\/th\u003e\n\u003ctd\u003eTCG280 covers AM302x–AM304x ECN1113\/EQN1125. OEM v1.5 repeats EQN1325 in the singleturn row; this proposal only uses the unambiguous multiturn row.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eConditional TI-5000JX bench scope: Check the larger-frame EQN1325 multiturn option, 17-contact connection and motor data; verify the fitted encoder label. Match the fitted drawing and enabled test profile.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5083 on the verified 17-contact EnDat connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eMatch exact profile, supply, connector and installed software; named cable evidence is not a complete setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eMotor-run setup remains conditional: verify exact motor, poles, power\/brake wiring, direction, alignment and installed TI-3000JX profile.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe admission evidence is Beckhoff AM Series Motors — AM3 EnDat family; OEM section 6.3.9 large-frame multiturn option. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eCurrent exact-order availability and an approved successor have not been confirmed. The linked technical references identify a configuration, not stock or universal replacement compatibility. Compare full labels, mechanics, interface, connector and motor data before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVerified technical scope\u003c\/th\u003e\n\u003ctd\u003eCheck the larger-frame EQN1325 multiturn option, 17-contact connection and motor data; verify the fitted encoder label.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact fitted order\u003c\/th\u003e\n\u003ctd\u003eFull suffix\/ID, contact drawing, supply and receiver must match the actual assembly. Family specifications do not establish every unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions, fasteners and torque\u003c\/th\u003e\n\u003ctd\u003eUse the matching manufacturer drawing and revision. Unverified dimensions, air gap, torque and pin assignments remain open.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eEnDat exchanges absolute position and device information through clock\/data communication. Analogue tracks exist only on the stated order. Keep serial bits, analogue periods and revolution range distinct, and verify whether EnDat01 or EnDat22 is actually fitted. Serial feedback must be selected by its actual protocol, code and returned identity. Record the incoming position, status and any supported revolution field before changes. Drive scaling, nominal encoder resolution and a tester menu designation are separate observations. A valid count does not establish mechanical fit, correct motor data or commutation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003ePhotograph the incoming shaft reference, locating seat, restraint, fasteners and cable exit before removal. After isolation, inspect accessible looseness, contamination, bearing roughness and rubbing. The actual drawing determines whether the unit has integral bearings, a clamped shaft or motor-supported sensing. Do not force a sensing assembly or substitute a torque from a similar model.\u003c\/p\u003e\n\u003cp\u003eThe AM3000\/AM3500 manual v1.5 section 6.3.9 identifies EQN1325 for AM305x–AM307x multiturn feedback. The same manual also repeats EQN1325 in the singleturn row. This guide uses only the explicit multiturn row; it neither corrects that row by inference nor extends coverage to AM308.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eRecord the sensor plug, internal motor loom, motor bulkhead, external machine cable and drive\/tester end as separate interfaces. Confirm gender, keying, contact numbering and mating-versus-termination view. Keep feedback, temperature, brake, motor power and shield contacts identified individually. A named test lead is not a pin map for an unverified adapter.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5083 on the verified 17-contact EnDat connection. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eNo internal OEM loom number or universal extension has been established for the exact fitted unit. Obtain its motor assembly drawing and both loom-end photographs. Select fixed or cable-carrier cable according to the actual installation, shielding and flex requirements. Mitchell lead numbers describe test fixtures and are not OEM replacement harness numbers.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration to establish first\u003c\/th\u003e\n\u003ctd\u003eThe AM3000\/AM3500 manual v1.5 section 6.3.9 identifies EQN1325 for AM305x–AM307x multiturn feedback. The same manual also repeats EQN1325 in the singleturn row. This guide uses only the explicit multiturn row; it neither corrects that row by inference nor extends coverage to AM308.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault when the cable moves\u003c\/th\u003e\n\u003ctd\u003eWith power isolated and both cable ends disconnected, inspect flex points, repairs, engagement and contamination. Check continuity and unwanted shorts using the correct contact drawing, allowing for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo signal or communication\u003c\/th\u003e\n\u003ctd\u003eConfirm the fitted order and approved fixture before a qualified technician measures the specified supply using the OEM procedure. Compare source and load at the appropriate breakout; a connector shell does not specify voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition moves but the drive still rejects feedback\u003c\/th\u003e\n\u003ctd\u003eRecord identity, position, alarms and direction. Check the supported signal paths, retention and motor pairing separately; do not reset or overwrite data as a first diagnostic step.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming mechanical datum, direction and motor phase convention before disturbing feedback. Preserve recoverable identity, offsets and parameters where the exact interface and equipment support reading. There is no universal angle or memory image for this family. A specialist replacement requires the fitted motor procedure, supported fixture and verified hardware\/data compatibility. Mitchell’s Beckhoff article does not decode the motor-memory contents; verify whether data can be read\/saved before removal and do not infer a compatible memory image.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eAM305x–AM307x EQN1325. TCG280 covers AM302x–AM304x ECN1113\/EQN1125. OEM v1.5 repeats EQN1325 in the singleturn row; this proposal only uses the unambiguous multiturn row.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/19869912288539-Beckhoff-AM-Series-Motors\" target=\"_blank\" rel=\"noopener\"\u003eBeckhoff AM Series Motors\u003c\/a\u003e — AM3 EnDat family; OEM section 6.3.9 large-frame multiturn option\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/download.beckhoff.com\/download\/document\/motion\/am3000_am3500_ba_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBeckhoff AM3000 \/ AM3500 manual v1.5, section 6.3.9\u003c\/a\u003e — Use the stated family, option and document revision only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExact fitted order, internal loom, contact view, fixture, supply and motor-specific setup remain to verify. The linked family PDF is not an exact-unit identity or interchangeability approval.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a AM305x–AM307x EQN1325 enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eMotor-run setup remains conditional: verify exact motor, poles, power\/brake wiring, direction, alignment and installed TI-3000JX profile. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"related\"\u003e\u003ch2\u003eRelated technical guides\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/sparefaber.com\/products\/beckhoff-am302x-am304x-endat-ecn1113-eqn1125-feedback\" target=\"_blank\" rel=\"noopener\"\u003eTCG280 — Beckhoff AM302x–AM304x EnDat option EnDat Servo Motor Feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51145597452453,"sku":"TCG571","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/beckhoff-am305x-am307x-eqn1325-service-guide.jpg?v=1794333659","url":"https:\/\/www.sparefaber.com\/de\/products\/beckhoff-am305x-am307x-eqn1325-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}