{"product_id":"br-8lva23-b1030d027-0-heidenhain-ebi1135-endat-feedback","title":"B\u0026R 8LVA23.B1030D027-0 EBI 1135 Battery-Buffered EnDat | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eMatch the B\u0026amp;R motor order and the EBI 1135 label before testing. The encoder is battery-buffered. Mitchell documents an EQI1131 tester workaround for EBI 1135 and links this exact 8LVA23 motor datasheet as an application example.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"B\u0026amp;R 8LVA23.B1030D027-0 EBI 1135 Battery-Buffered EnDat technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Mitchell specifies the EQI1131 workaround for live angle and position. It reports an expected ID mismatch and stuck-bit indication and displays 12 of the 16 turn bits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Mitchell specifies Generic Endat RunSer \u0026gt; EQ...31 for EBI 1135. Confirm the exact motor, power cable and saved phase reference before a controlled run.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e TI-5731 for the documented 12-contact Springtec 8LVA EBI connection.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eB\u0026amp;R 8LVA23.B1030D027-0 EBI 1135 Battery-Buffered EnDat technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8LVA23.B1030D027-0\u003c\/th\u003e\n\u003ctd\u003eExact B\u0026amp;R order in Mitchell’s linked motor datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEBI 1135\u003c\/th\u003e\n\u003ctd\u003eInductive battery-buffered multiturn EnDat feedback. Check the complete encoder ID.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEQI1131\u003c\/th\u003e\n\u003ctd\u003eMitchell’s software selection for the stated EBI workaround. The selection has display limitations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLink and retention\u003c\/th\u003e\n\u003ctd\u003eEnDat 2.2 digital position with a separate retention circuit on the EBI path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTurn field\u003c\/th\u003e\n\u003ctd\u003eMitchell describes the full 16-bit turn field and the workaround’s 12 displayed bits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead\u003c\/th\u003e\n\u003ctd\u003eTI-5731 for the 12-contact B\u0026amp;R motor connection. Mitchell lists TI-5717 separately for the matched EBI internal connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe receiver reads live position over EnDat while the EBI retention circuit keeps turn information across power loss. Judge the live angle and retained turns separately. Record the fitted ID before comparing counts against an OEM data sheet.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the B\u0026amp;R motor document and the exact EBI mounting drawing to check rotor fit, mounting face, sensor gap and cable strain. The EBI 1135 is an inductive modular assembly. Preserve the motor reference before separating parts.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eIdentify supply, differential serial pairs and retention connections at the correct view. Compare the B\u0026amp;R Springtec motor-side drawing with the separate fitted HEIDENHAIN PCB view before selecting the test lead.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the factory lead, motor extension and battery path independently. Follow the OEM retention procedure before disconnecting the encoder or measuring the battery circuit.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEQN1335 ID error or stuck bit in the EQI1131 workaround\u003c\/th\u003e\n\u003ctd\u003eMitchell documents both displays for this workaround. Confirm the actual EBI label and compare live angle and link integrity separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMissing turns after loss of power\u003c\/th\u003e\n\u003ctd\u003eCheck the approved retention circuit and distinguish the tester’s 12-bit view from loss of the full turn field.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValid position with motor enable fault\u003c\/th\u003e\n\u003ctd\u003eCompare the original B\u0026amp;R memory, motor selection, and recorded reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eMitchell’s B+R Memory Test can read the original motor’s stored alignment. Capture the incoming mechanical reference and save that data. Check compatibility and the B\u0026amp;R commissioning steps before any data transfer.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eB\u0026amp;R 8LVA, exact Mitchell-linked example\u003c\/p\u003e\n\u003cp\u003eSeparate expected workaround behavior from a failed encoder and preserve the B\u0026amp;R alignment memory.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/de\/products\/br-8lsaa2-d8045s000-3-hybrid-endat\"\u003eB\u0026amp;R 8LSAA2.D8045S000-3 Hybrid EnDat22 Motor Feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/39306220454555-Heidenhain-EBI-1135-Support\"\u003eHeidenhain EBI 1135 Support\u003c\/a\u003e. TI-5000JX setup, B+R Memory Test and linked 8LVA23 sample\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cws.o.br-automation.com\/en-in\/products\/motion-control\/additional-information\/8lva-order-key\/\"\u003eB\u0026amp;R 8LVA order key and encoder systems\u003c\/a\u003e. Supplementary reference for the stated model or setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell Test Cable Index by Manufacturer\u003c\/a\u003e. Reference for the fitted feedback or motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.dropbox.com\/scl\/fi\/j5s1ausq3csesu6ztlgzu\/B-R_8LVA23.B1030D027-0_EBI1135.pdf?rlkey=pi8gz2l4ykvi6ltnh0q2e1ms6\u0026amp;e=1\u0026amp;dl=0\"\u003eMitchell-linked B\u0026amp;R 8LVA23.B1030D027-0 and EBI 1135 sample\u003c\/a\u003e. Reference for the fitted feedback or motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/rotary-encoders\/820725-11\"\u003eHEIDENHAIN EBI 1135 ID 820725-11\u003c\/a\u003e. Example EBI order and installation reference. Compare its full ID with the fitted unit before using its electrical or mechanical limits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51134536188069,"sku":"TCG337","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/br-8lva23-b1030d027-0-heidenhain-ebi1135-endat-feedback-service-guide.jpg?v=1794298554","url":"https:\/\/www.sparefaber.com\/de\/products\/br-8lva23-b1030d027-0-heidenhain-ebi1135-endat-feedback","provider":"SpareFaber","version":"1.0","type":"link"}